Image quality and clinical usefulness of automatic tube current modulation technology in female chest computed tomography screening. Issue 33 (14th August 2020)
- Record Type:
- Journal Article
- Title:
- Image quality and clinical usefulness of automatic tube current modulation technology in female chest computed tomography screening. Issue 33 (14th August 2020)
- Main Title:
- Image quality and clinical usefulness of automatic tube current modulation technology in female chest computed tomography screening
- Authors:
- Li, Cheng
Qi, Lin
Zhang, Yusheng
Gao, Feng
Jin, Xiu
Zhang, Lukai
Tang, Huan
Li, Ming - Other Names:
- Sung. Wen-Wei section editor.
- Abstract:
- Abstract : Abstract: The study was aimed to evaluate the image quality and radiation dose during female chest computed tomography (CT) screening using organ-based tube current modulation technology X-ray combined applications to reduce exposure (XCARE). Five hundred sixty female individuals undergoing chest CT scan were prospectively enrolled and divided into 4 groups based on body mass index (BMI). Then they were randomly and equally divided into control and experimental subgroup and respectively accepted conventional low-dose and XCARE technology spiral CT scan with same parameters. Signal-to-noise ratio and contrast-to-noise ratio were calculated. The quality of the images was evaluated by 2 radiologists using a 5-point scale. Among experimental subgroups of the 4 BMI groups, Signal-to-noise ratios, CT dose index of volume, dose-length product, effective dose, and contrast-to-noise ratio all displayed significant differences, as well as in control subgroups ( P < .001). Both the experimental and control subgroups showed an increasing trend in radiation dose with the increasing of BMI. Parameters of image quality and radiation dose displayed no significant differences between control and experimental subgroups in the 4 groups. In multiple linear regression analysis, age and scanning protocol were not associated with radiation dose ( P > .05), while BMI was significantly associated with increased CT dose index of volume ( P < .05). The display of the lesions for theAbstract : Abstract: The study was aimed to evaluate the image quality and radiation dose during female chest computed tomography (CT) screening using organ-based tube current modulation technology X-ray combined applications to reduce exposure (XCARE). Five hundred sixty female individuals undergoing chest CT scan were prospectively enrolled and divided into 4 groups based on body mass index (BMI). Then they were randomly and equally divided into control and experimental subgroup and respectively accepted conventional low-dose and XCARE technology spiral CT scan with same parameters. Signal-to-noise ratio and contrast-to-noise ratio were calculated. The quality of the images was evaluated by 2 radiologists using a 5-point scale. Among experimental subgroups of the 4 BMI groups, Signal-to-noise ratios, CT dose index of volume, dose-length product, effective dose, and contrast-to-noise ratio all displayed significant differences, as well as in control subgroups ( P < .001). Both the experimental and control subgroups showed an increasing trend in radiation dose with the increasing of BMI. Parameters of image quality and radiation dose displayed no significant differences between control and experimental subgroups in the 4 groups. In multiple linear regression analysis, age and scanning protocol were not associated with radiation dose ( P > .05), while BMI was significantly associated with increased CT dose index of volume ( P < .05). The display of the lesions for the patients in the control and experimental subgroups of the 4 groups with different BMIs exhibited no statistically significant difference. The same image quality and radiation dose can be obtained using XCARE technology compared to conventional chest CT scans, which can be used regularly in female patients. Advances in knowledge: Using automatic tube current modulation technology to reduce exposure in breast. In this study, we sought a radiation protection method for sensitive tissue in chest CT screening. Abstract : Supplemental Digital Content is available in the text … (more)
- Is Part Of:
- Medicine. Volume 99:Issue 33(2020)
- Journal:
- Medicine
- Issue:
- Volume 99:Issue 33(2020)
- Issue Display:
- Volume 99, Issue 33 (2020)
- Year:
- 2020
- Volume:
- 99
- Issue:
- 33
- Issue Sort Value:
- 2020-0099-0033-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-08-14
- Subjects:
- breast -- computed tomography -- dose-saving technique -- radiation -- X-ray combined applications to reduce exposure
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000021719 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13976.xml