Glycosaminoglycan depletion increases energy dissipation in articular cartilage under high-frequency loading. (October 2020)
- Record Type:
- Journal Article
- Title:
- Glycosaminoglycan depletion increases energy dissipation in articular cartilage under high-frequency loading. (October 2020)
- Main Title:
- Glycosaminoglycan depletion increases energy dissipation in articular cartilage under high-frequency loading
- Authors:
- Han, Guebum
Boz, Utku
Eriten, Melih
Henak, Corinne R. - Abstract:
- Abstract: High-frequency material behavior of cartilage at macroscopic lengths is not widely understood, despite a wide range of frequencies and contact lengths experienced in vivo . For example, cartilage at different stages of matrix integrity can experience high-frequency loading during traumatic impact, making high-frequency behavior relevant in the context of structural failure. Therefore, this study examined macroscopic dissipative and mechanical responses of intact and glycosaminoglycan (GAG)-depleted cartilage under previously unexplored high-frequency loading. These dynamic responses were complemented with the evaluation of quasi-static responses. A custom dynamic mechanical analyzer was used to obtain dynamic behavior, and stress relaxation testing was performed to obtain quasi-static behavior. Under high-frequency loading, cartilage energy dissipation increased with GAG depletion and decreased with strain; dynamic modulus exhibited opposite trends. Similarly, under quasi-static loading, equilibrium modulus and relaxation time of cartilage decreased with GAG depletion. The increased energy dissipation after GAG depletion under high-frequency loading was likely due to increased viscoelastic dissipation. These findings broaden our understanding of fundamental properties of cartilage as a function of solid matrix integrity in an unprecedented loading regime. They also provide a foundation for analyzing energy dissipation associated with cartilage failure induced byAbstract: High-frequency material behavior of cartilage at macroscopic lengths is not widely understood, despite a wide range of frequencies and contact lengths experienced in vivo . For example, cartilage at different stages of matrix integrity can experience high-frequency loading during traumatic impact, making high-frequency behavior relevant in the context of structural failure. Therefore, this study examined macroscopic dissipative and mechanical responses of intact and glycosaminoglycan (GAG)-depleted cartilage under previously unexplored high-frequency loading. These dynamic responses were complemented with the evaluation of quasi-static responses. A custom dynamic mechanical analyzer was used to obtain dynamic behavior, and stress relaxation testing was performed to obtain quasi-static behavior. Under high-frequency loading, cartilage energy dissipation increased with GAG depletion and decreased with strain; dynamic modulus exhibited opposite trends. Similarly, under quasi-static loading, equilibrium modulus and relaxation time of cartilage decreased with GAG depletion. The increased energy dissipation after GAG depletion under high-frequency loading was likely due to increased viscoelastic dissipation. These findings broaden our understanding of fundamental properties of cartilage as a function of solid matrix integrity in an unprecedented loading regime. They also provide a foundation for analyzing energy dissipation associated with cartilage failure induced by traumatic impact. Graphical abstract: Image 1 Highlights: Macroscopic cartilage dissipation is investigated under high-frequency loading. Glycosaminoglycan deletion increases macroscopic cartilage dissipation. Macroscopic cartilage dissipation is strain-dependent. Glycosaminoglycan deletion decreases moduli and relaxation time of cartilage. Findings extend understanding of macroscopic dissipation under traumatic loading. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 110(2020)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 110(2020)
- Issue Display:
- Volume 110, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 110
- Issue:
- 2020
- Issue Sort Value:
- 2020-0110-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-10
- Subjects:
- Energy dissipation -- Glycosaminoglycan -- Osteoarthritis -- High-frequency loading -- Quasi-static loading
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2020.103876 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13983.xml