3D full-field strain in bone-implant and bone-tooth constructs and their morphological influential factors. (October 2020)
- Record Type:
- Journal Article
- Title:
- 3D full-field strain in bone-implant and bone-tooth constructs and their morphological influential factors. (October 2020)
- Main Title:
- 3D full-field strain in bone-implant and bone-tooth constructs and their morphological influential factors
- Authors:
- Zhou, Yuxiao
Gong, Chujie
Hossaini-Zadeh, Mehran
Du, Jing - Abstract:
- Abstract: The biomechanics of bone-tooth and bone-implant interfaces affects the outcomes of several dental treatments, such as implant placement, because bone, tooth and periodontal ligament are living tissues that adapt to the changes in mechanical stimulations. In this work, mechanical testing coupled with micro-CT was performed on human cadaveric mandibular bone-tooth and bone-implant constructs. Using digital volume correlation, the 3D full-field strain in bone under implant loading and tooth loading was measured. Concurrently, bone morphology and bone-implant and bone-tooth contact were also measured through the analysis of micro-CT images. The results show that strain in bone increased when a tooth was replaced by a dental implant. Strain concentration was observed in peri-implant bone, as well as in the buccal bone plate, which is also the clinically-observed bone resorption area after implant placement. Decreasing implant stability measurements (resonance frequency analysis and torque test) indicated increased peri-implant strain, but their relationships may not be linear. Peri-implant bone strain linearly increased with decreasing bone-implant contact (BIC) ratio. It also linearly decreased with increasing bone-tooth/bone-implant contact ratio. The high strain in the buccal bone plate linearly increased with decreasing buccal bone plate thickness. The results of this study revealed 3D full-field strain in bone-tooth and bone-implant constructs, as well as theirAbstract: The biomechanics of bone-tooth and bone-implant interfaces affects the outcomes of several dental treatments, such as implant placement, because bone, tooth and periodontal ligament are living tissues that adapt to the changes in mechanical stimulations. In this work, mechanical testing coupled with micro-CT was performed on human cadaveric mandibular bone-tooth and bone-implant constructs. Using digital volume correlation, the 3D full-field strain in bone under implant loading and tooth loading was measured. Concurrently, bone morphology and bone-implant and bone-tooth contact were also measured through the analysis of micro-CT images. The results show that strain in bone increased when a tooth was replaced by a dental implant. Strain concentration was observed in peri-implant bone, as well as in the buccal bone plate, which is also the clinically-observed bone resorption area after implant placement. Decreasing implant stability measurements (resonance frequency analysis and torque test) indicated increased peri-implant strain, but their relationships may not be linear. Peri-implant bone strain linearly increased with decreasing bone-implant contact (BIC) ratio. It also linearly decreased with increasing bone-tooth/bone-implant contact ratio. The high strain in the buccal bone plate linearly increased with decreasing buccal bone plate thickness. The results of this study revealed 3D full-field strain in bone-tooth and bone-implant constructs, as well as their several morphological influential factors. Graphical abstract: Image 1 Highlights: 3D full-field bone strain and morphology by mechanical testing with micro-CT. Strain in bone generally increased when a tooth was replaced by a dental implant. Peri-implant bone strain linearly increased with decreasing bone-implant contact. It also linearly decreased with increasing bone-tooth/bone-implant contact ratio. Strain in buccal bone plate (BBP) linearly increased with decreasing BBP thickness. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 110(2020)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 110(2020)
- Issue Display:
- Volume 110, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 110
- Issue:
- 2020
- Issue Sort Value:
- 2020-0110-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-10
- Subjects:
- Dental implant -- Strain -- Micro-CT -- Digital volume correlation
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2020.103858 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13983.xml