Six-Month Outcomes From the First-in-Human, Single-Arm SELUTION Sustained-Limus-Release Drug-Eluting Balloon Trial in Femoropopliteal Lesions. (October 2020)
- Record Type:
- Journal Article
- Title:
- Six-Month Outcomes From the First-in-Human, Single-Arm SELUTION Sustained-Limus-Release Drug-Eluting Balloon Trial in Femoropopliteal Lesions. (October 2020)
- Main Title:
- Six-Month Outcomes From the First-in-Human, Single-Arm SELUTION Sustained-Limus-Release Drug-Eluting Balloon Trial in Femoropopliteal Lesions
- Authors:
- Zeller, Thomas
Brechtel, Klaus
Meyer, Dirk-Roelfs
Noory, Elias
Beschorner, Ulrich
Albrecht, Thomas - Abstract:
- Purpose: To evaluate the safety and efficacy of the novel SELUTION sustained-limus-release (SLR) drug-eluting balloon (DEB) in the treatment of femoropopliteal lesions.Materials and Methods: Between October 2016 and May 2017, 50 subjects (mean age 69.6±10.4 years; 29 men) with symptomatic moderate to severe lower limb ischemia (Rutherford categories 2 or 3) were enrolled at 4 German centers for the SELUTION SLR first-in-human trial ( ClinicalTrials.gov NCT02941224). The SELUTION SLR utilizes micro-reservoirs (biodegradable polymer spheres containing sirolimus) embedded within an amphipathic membrane coated onto an angioplasty balloon. The biodegradable reservoirs are transferred to the target vessel lumen during brief balloon inflation. The primary trial objective was comparison of angiographic late lumen loss at 6 months against an objective performance criterion (OPC) value of 1.04 mm for uncoated balloon angioplasty. Secondary endpoints included device, procedural, and clinical success; clinical and imaging assessments of primary patency and restenosis; functional assessments including Rutherford category and ankle-brachial index (ABI); and major adverse events [composite of cardiovascular mortality, index limb amputation, target limb thrombosis, and clinically-driven target lesion revascularization (CD-TLR)].Results: At 6 months, median angiographic late lumen loss following SELUTION SLR treatment was 0.19 mm (range −1.16 to 3.07). Mean angiographic late lumen lossPurpose: To evaluate the safety and efficacy of the novel SELUTION sustained-limus-release (SLR) drug-eluting balloon (DEB) in the treatment of femoropopliteal lesions.Materials and Methods: Between October 2016 and May 2017, 50 subjects (mean age 69.6±10.4 years; 29 men) with symptomatic moderate to severe lower limb ischemia (Rutherford categories 2 or 3) were enrolled at 4 German centers for the SELUTION SLR first-in-human trial ( ClinicalTrials.gov NCT02941224). The SELUTION SLR utilizes micro-reservoirs (biodegradable polymer spheres containing sirolimus) embedded within an amphipathic membrane coated onto an angioplasty balloon. The biodegradable reservoirs are transferred to the target vessel lumen during brief balloon inflation. The primary trial objective was comparison of angiographic late lumen loss at 6 months against an objective performance criterion (OPC) value of 1.04 mm for uncoated balloon angioplasty. Secondary endpoints included device, procedural, and clinical success; clinical and imaging assessments of primary patency and restenosis; functional assessments including Rutherford category and ankle-brachial index (ABI); and major adverse events [composite of cardiovascular mortality, index limb amputation, target limb thrombosis, and clinically-driven target lesion revascularization (CD-TLR)].Results: At 6 months, median angiographic late lumen loss following SELUTION SLR treatment was 0.19 mm (range −1.16 to 3.07). Mean angiographic late lumen loss (n=34) was 0.29±0.84 mm (95% CI −0.01 to 0.58), significantly lower than the 1.04-mm OPC value (p<0.001). The rate of primary patency by duplex ultrasound was 88.4%, and freedom from angiographic binary restenosis was 91.2%. Through 6 months, there was significant improvement over baseline in Rutherford categories (p<0.001) and in ABI measurements (p<0.001). A single case (2%) of CD-TLR occurred at 5 months. There were no other major adverse events.Conclusion: Through 6 months, the SELUTION SLR DEB appears to inhibit restenosis effectively and safely, improving outcomes in subjects with symptomatic femoropopliteal disease. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 27:Number 5(2020:Oct.)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 27:Number 5(2020:Oct.)
- Issue Display:
- Volume 27, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 27
- Issue:
- 5
- Issue Sort Value:
- 2020-0027-0005-0000
- Page Start:
- 683
- Page End:
- 690
- Publication Date:
- 2020-10
- Subjects:
- angiographic late lumen loss -- drug-eluting balloon -- femoropopliteal segment -- paclitaxel-coated balloon -- peripheral artery disease -- popliteal artery -- restenosis -- sirolimus -- superficial femoral artery
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1526602820941811 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13963.xml