Have newer bearing surfaces changed expectations regarding the longevity of total hip arthroplasty?. (July 2020)
- Record Type:
- Journal Article
- Title:
- Have newer bearing surfaces changed expectations regarding the longevity of total hip arthroplasty?. (July 2020)
- Main Title:
- Have newer bearing surfaces changed expectations regarding the longevity of total hip arthroplasty?
- Authors:
- Engh, Jr., Charles A.
McAsey, Craig J.
Cororaton, Agnes D.
Ho, Henry
Hopper, Jr., Robert H. - Abstract:
- Abstract : Aims: The purpose of this study is to examine six types of bearing surfaces implanted at a single institution over three decades to determine whether the reasons for revision vary among the groups and how long it takes to identify differences in survival. Methods: We considered six cohorts that included a total of 1, 707 primary hips done between 1982 and 2010. These included 223 conventional polyethylene sterilized with γ irradiation in air (CPE-GA), 114 conventional polyethylene sterilized with gas plasma (CPE-GP), 116 crosslinked polyethylene (XLPE), 1, 083 metal-on-metal (MOM), 90 ceramic-on-ceramic (COC), and 81 surface arthroplasties (SAs). With the exception of the COC, all other groups used cobalt-chromium (CoCr) femoral heads. The mean follow-up was 10 (0.008 to 35) years. Descriptive statistics with revisions per 100 component years (re/100 yr) and survival analysis with revision for any reason as the endpoint were used to compare bearing surfaces. Results: XLPE liners demonstrated a lower cumulative incidence of revision at 15 years compared to the CPE-GA and CPE-GP groups owing to the absence of wear-related revisions (4% for XLPE vs 18%, p = 0.02, and 15%, p = 0.003, respectively). Revisions for adverse local tissue reactions occurred exclusively among the MOM (0.8 re/100 year) and SA groups (0.1 re/100 year). The revision rate for instability was lower among hips with 36 mm and larger head sizes compared to smaller head sizes (0.2% vs 2%, p < 0.001).Abstract : Aims: The purpose of this study is to examine six types of bearing surfaces implanted at a single institution over three decades to determine whether the reasons for revision vary among the groups and how long it takes to identify differences in survival. Methods: We considered six cohorts that included a total of 1, 707 primary hips done between 1982 and 2010. These included 223 conventional polyethylene sterilized with γ irradiation in air (CPE-GA), 114 conventional polyethylene sterilized with gas plasma (CPE-GP), 116 crosslinked polyethylene (XLPE), 1, 083 metal-on-metal (MOM), 90 ceramic-on-ceramic (COC), and 81 surface arthroplasties (SAs). With the exception of the COC, all other groups used cobalt-chromium (CoCr) femoral heads. The mean follow-up was 10 (0.008 to 35) years. Descriptive statistics with revisions per 100 component years (re/100 yr) and survival analysis with revision for any reason as the endpoint were used to compare bearing surfaces. Results: XLPE liners demonstrated a lower cumulative incidence of revision at 15 years compared to the CPE-GA and CPE-GP groups owing to the absence of wear-related revisions (4% for XLPE vs 18%, p = 0.02, and 15%, p = 0.003, respectively). Revisions for adverse local tissue reactions occurred exclusively among the MOM (0.8 re/100 year) and SA groups (0.1 re/100 year). The revision rate for instability was lower among hips with 36 mm and larger head sizes compared to smaller head sizes (0.2% vs 2%, p < 0.001). Conclusion: The introduction of XLPE has eliminated wear-related revisions through 15-year follow-up compared to CPE-GP and CPE-GA. Dislocation incidence has been reduced with the introduction of larger diameter heads but remains a persistent concern. The potential for adverse local tissue reactions with MOM requires continued follow-up. Cite this article: Bone Joint J 2020;102-B(7 Supple B):105–111. … (more)
- Is Part Of:
- Bone & joint journal. Volume 102B:Number 7(2020) Supplement B
- Journal:
- Bone & joint journal
- Issue:
- Volume 102B:Number 7(2020) Supplement B
- Issue Display:
- Volume 102, Issue 7 (2020)
- Year:
- 2020
- Volume:
- 102
- Issue:
- 7
- Issue Sort Value:
- 2020-0102-0007-0000
- Page Start:
- 105
- Page End:
- 111
- Publication Date:
- 2020-07
- Subjects:
- total hip arthroplasty -- crosslinked polyethylene -- ceramic -- metal-on-metal -- outcome -- revision -- hemispheric cementless cup -- extensively porous-coated cylindrical stems
Bones -- Surgery -- Periodicals
Joints -- Surgery -- Periodicals
Orthopedic surgery -- Periodicals
617.47005 - Journal URLs:
- http://www.bjj.boneandjoint.org.uk/ ↗
- DOI:
- 10.1302/0301-620X.102B7.BJJ-2019-1545.R1 ↗
- Languages:
- English
- ISSNs:
- 2049-4394
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library STI - ELD Digital store
- Ingest File:
- 13963.xml