Room‐temperature performance of 3 mm‐thick cadmium–zinc–telluride pixel detectors with sub‐millimetre pixelization. (17th August 2020)
- Record Type:
- Journal Article
- Title:
- Room‐temperature performance of 3 mm‐thick cadmium–zinc–telluride pixel detectors with sub‐millimetre pixelization. (17th August 2020)
- Main Title:
- Room‐temperature performance of 3 mm‐thick cadmium–zinc–telluride pixel detectors with sub‐millimetre pixelization
- Authors:
- Buttacavoli, Antonino
Principato, Fabio
Gerardi, Gaetano
Bettelli, Manuele
Sarzi Amadè, Nicola
Zappettini, Andrea
Seller, Paul
Veale, Matthew C.
Fox, Oliver
Sawhney, Kawal
Abbene, Leonardo - Abstract:
- Abstract : In this work, the room‐temperature performance of 3 mm‐thick cadmium–zinc–telluride (CZT) pixel detectors with sub‐millimetre arrays is presented. The detectors allow high‐bias voltage operation (6000 V cm −1 electric field) with energy resolution values of less than 2 keV up to 140 keV. Abstract : Cadmium–zinc–telluride (CZT) pixel detectors represent a consolidated choice for the development of room‐temperature spectroscopic X‐ray imagers, finding important applications in medical imaging, often as detection modules of a variety of new SPECT and CT systems. Detectors with 3–5 mm thicknesses are able to efficiently detect X‐rays up to 140 keV giving reasonable room‐temperature energy resolution. In this work, the room‐temperature performance of 3 mm‐thick CZT pixel detectors, recently developed at IMEM/CNR of Parma (Italy), is presented. Sub‐millimetre detector arrays with pixel pitch less than 500 µm were fabricated. The detectors are characterized by good room‐temperature performance even at high bias voltage operation (6000 V cm −1 ), with energy resolutions (FWHM) of 3% (1.8 keV) and 1.6% (2 keV) at 59.5 keV and 122.1 keV, respectively. Charge‐sharing investigations were performed with both uncollimated and collimated synchrotron X‐ray beams with particular attention to recovering the charge losses at the inter‐pixel gap region. High rate measurements demonstrated the absence of high‐flux radiation‐induced polarization phenomena up to 25 × 10 6 photons mm −2Abstract : In this work, the room‐temperature performance of 3 mm‐thick cadmium–zinc–telluride (CZT) pixel detectors with sub‐millimetre arrays is presented. The detectors allow high‐bias voltage operation (6000 V cm −1 electric field) with energy resolution values of less than 2 keV up to 140 keV. Abstract : Cadmium–zinc–telluride (CZT) pixel detectors represent a consolidated choice for the development of room‐temperature spectroscopic X‐ray imagers, finding important applications in medical imaging, often as detection modules of a variety of new SPECT and CT systems. Detectors with 3–5 mm thicknesses are able to efficiently detect X‐rays up to 140 keV giving reasonable room‐temperature energy resolution. In this work, the room‐temperature performance of 3 mm‐thick CZT pixel detectors, recently developed at IMEM/CNR of Parma (Italy), is presented. Sub‐millimetre detector arrays with pixel pitch less than 500 µm were fabricated. The detectors are characterized by good room‐temperature performance even at high bias voltage operation (6000 V cm −1 ), with energy resolutions (FWHM) of 3% (1.8 keV) and 1.6% (2 keV) at 59.5 keV and 122.1 keV, respectively. Charge‐sharing investigations were performed with both uncollimated and collimated synchrotron X‐ray beams with particular attention to recovering the charge losses at the inter‐pixel gap region. High rate measurements demonstrated the absence of high‐flux radiation‐induced polarization phenomena up to 25 × 10 6 photons mm −2 s −1 . … (more)
- Is Part Of:
- Journal of synchrotron radiation. Volume 27:Part 5(2020)
- Journal:
- Journal of synchrotron radiation
- Issue:
- Volume 27:Part 5(2020)
- Issue Display:
- Volume 27, Issue 5, Part 5 (2020)
- Year:
- 2020
- Volume:
- 27
- Issue:
- 5
- Part:
- 5
- Issue Sort Value:
- 2020-0027-0005-0005
- Page Start:
- 1180
- Page End:
- 1189
- Publication Date:
- 2020-08-17
- Subjects:
- X‐ray and gamma ray detectors -- CdZnTe pixel detectors -- charge sharing -- charge losses -- charge‐sharing correction -- spectroscopic X‐ray imaging
Synchrotron radiation -- Periodicals
Free electron lasers -- Periodicals
539.73505 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1107/S16005775 ↗
http://journals.iucr.org/s/journalhomepage.html ↗
http://www.blackwell-synergy.com/openurl?genre=journal&issn=0909-0495 ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1107/S1600577520008942 ↗
- Languages:
- English
- ISSNs:
- 0909-0495
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5068.035000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13935.xml