Accuracy of point‐of‐care intestinal ultrasound for Crohn's disease. Issue 3 (24th July 2020)
- Record Type:
- Journal Article
- Title:
- Accuracy of point‐of‐care intestinal ultrasound for Crohn's disease. Issue 3 (24th July 2020)
- Main Title:
- Accuracy of point‐of‐care intestinal ultrasound for Crohn's disease
- Authors:
- Wright, Emily K.
Wang, Ian
Wong, Darren
Bell, Sally J.
Connell, William R.
Thompson, Alexander J.
Novak, Kerri L.
Kamm, Michael A. - Abstract:
- Abstract: Background: Point‐of‐care ultrasound (POCUS), performed by a gastroenterologist, provides safe and convenient imaging allowing for immediate clinical decision in Crohn's disease. The minimum training required to gain competency, its accuracy and clinical utility requires evaluation. Methods: In this pilot study, Crohn's disease activity and extent were assessed using POCUS (performed by a single gastroenterologist following the completion of 200 supervised scans), magnetic resonance enterography (MRE) and ileo‐colonoscopy. The presence of complications was assessed by POCUS and MRE. Accuracy of POCUS was analysed with respect to MRE and ileo‐colonoscopy. Agreement between modalities was assessed using kappa coefficient. Results: Forty‐two patients had a POCUS paired with MRE. Thirty‐eight patients had a POCUS paired with ileo‐colonoscopy. When compared to MRE, POCUS was accurate in the assessment of disease activity (sensitivity 87.5%, specificity 61.1%, ROC 0.74), extent (sensitivity 77.8%, specificity 83.3%, ROC 0.81) and complications (sensitivity 85.7%, specificity 94.3%, ROC 0.90). Agreement between POCUS and MRE was moderate (kappa estimates 0.50, P < 0.001, 0.61, P < 0.001 and 0.76, P < 0.001) for disease activity, extent and complications, respectively. When compared to ileo‐colonoscopy, POCUS was accurate in the assessment of disease activity (sensitivity 72%, specificity 86%, ROC 0.79) and extent (sensitivity 85.7%, specificity 86%, ROC 0.86). For POCUSAbstract: Background: Point‐of‐care ultrasound (POCUS), performed by a gastroenterologist, provides safe and convenient imaging allowing for immediate clinical decision in Crohn's disease. The minimum training required to gain competency, its accuracy and clinical utility requires evaluation. Methods: In this pilot study, Crohn's disease activity and extent were assessed using POCUS (performed by a single gastroenterologist following the completion of 200 supervised scans), magnetic resonance enterography (MRE) and ileo‐colonoscopy. The presence of complications was assessed by POCUS and MRE. Accuracy of POCUS was analysed with respect to MRE and ileo‐colonoscopy. Agreement between modalities was assessed using kappa coefficient. Results: Forty‐two patients had a POCUS paired with MRE. Thirty‐eight patients had a POCUS paired with ileo‐colonoscopy. When compared to MRE, POCUS was accurate in the assessment of disease activity (sensitivity 87.5%, specificity 61.1%, ROC 0.74), extent (sensitivity 77.8%, specificity 83.3%, ROC 0.81) and complications (sensitivity 85.7%, specificity 94.3%, ROC 0.90). Agreement between POCUS and MRE was moderate (kappa estimates 0.50, P < 0.001, 0.61, P < 0.001 and 0.76, P < 0.001) for disease activity, extent and complications, respectively. When compared to ileo‐colonoscopy, POCUS was accurate in the assessment of disease activity (sensitivity 72%, specificity 86%, ROC 0.79) and extent (sensitivity 85.7%, specificity 86%, ROC 0.86). For POCUS and ileo‐colonoscopy, kappa estimates were 0.55, P < 0.001 for disease activity and 0.62, P < 0.001 for disease extent. Conclusion: POCUS performed by a gastroenterologist after completion of limited training is accurate for assessing Crohn's disease activity, extent and the presence of complications. … (more)
- Is Part Of:
- Australasian journal of ultrasound in medicine. Volume 23:Issue 3(2020)
- Journal:
- Australasian journal of ultrasound in medicine
- Issue:
- Volume 23:Issue 3(2020)
- Issue Display:
- Volume 23, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2020-0023-0003-0000
- Page Start:
- 176
- Page End:
- 182
- Publication Date:
- 2020-07-24
- Subjects:
- intestinal ultrasound -- GIUS -- POCUS -- Crohn's disease
Ultrasonics in medicine -- Periodicals
Ultrasonic imaging -- Periodicals
Ultrasonic imaging
Ultrasonics in medicine
Periodicals
616.075430 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2205-0140 ↗
http://www.minnisjournals.com.au/ajum ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ajum.12218 ↗
- Languages:
- English
- ISSNs:
- 1836-6864
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13937.xml