A versatile X‐ray phase retarder for lock‐in XMCD measurements. (6th August 2020)
- Record Type:
- Journal Article
- Title:
- A versatile X‐ray phase retarder for lock‐in XMCD measurements. (6th August 2020)
- Main Title:
- A versatile X‐ray phase retarder for lock‐in XMCD measurements
- Authors:
- Poldi, Eduardo H. T.
Escanhoela Jr, Carlos A.
Fonseca Jr, Jairo
Eleotério, Marcos A. S.
dos Reis, Ricardo D.
Lang, Jonathan C.
Haskel, Daniel
Souza-Neto, Narcizo M. - Abstract:
- Abstract : A versatile strategy to perform efficient X‐ray magnetic circular dichroism experiments with a quarter‐wave plate using a setup that combines non‐conventional dispersive optics with locked‐in acquisition, also compatible with monochromatic X‐ray beamlines and large magnets, is reported. Abstract : X‐ray magnetic circular dichroism (XMCD) is a technique commonly used to probe magnetic properties of materials with element and orbital selectivity, which requires the use of circularly polarized (CP) X‐rays. It is possible to accomplish XMCD experiments with fixed CP and alternating the magnetic field orientation, but most reliable data are obtained when alternating the magnetization orientation and the polarization between right and left helicities. A versatile strategy has been developed to perform XMCD experiments using a hard X‐ray quarter‐wave plate, at both polychromatic dispersive and conventional monochromatic optics, in combination with synchronous data acquisition. The switching frequency waveform is fed into a lock‐in amplifier to detect and amplify the XMCD signal. The results on a reference sample demonstrate an improvement in data quality and acquisition time. The instrumentation successfully generated 98% of CP X‐rays switching the beam helicity at 13 Hz, with the possibility of faster helicity switching once it is installed at the new Brazilian fourth‐generation source, SIRIUS.
- Is Part Of:
- Journal of synchrotron radiation. Volume 27:Part 5(2020)
- Journal:
- Journal of synchrotron radiation
- Issue:
- Volume 27:Part 5(2020)
- Issue Display:
- Volume 27, Issue 5, Part 5 (2020)
- Year:
- 2020
- Volume:
- 27
- Issue:
- 5
- Part:
- 5
- Issue Sort Value:
- 2020-0027-0005-0005
- Page Start:
- 1240
- Page End:
- 1246
- Publication Date:
- 2020-08-06
- Subjects:
- XMCD -- phase retarder -- lock‐in -- dichroism -- XAS -- instrumentation -- X‐ray spectroscopy -- magnetism
Synchrotron radiation -- Periodicals
Free electron lasers -- Periodicals
539.73505 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1107/S16005775 ↗
http://journals.iucr.org/s/journalhomepage.html ↗
http://www.blackwell-synergy.com/openurl?genre=journal&issn=0909-0495 ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1107/S1600577520009558 ↗
- Languages:
- English
- ISSNs:
- 0909-0495
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5068.035000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13935.xml