Enhanced predictive capacity using dual-parameter chip model that simulates physiological skin irritation. (October 2020)
- Record Type:
- Journal Article
- Title:
- Enhanced predictive capacity using dual-parameter chip model that simulates physiological skin irritation. (October 2020)
- Main Title:
- Enhanced predictive capacity using dual-parameter chip model that simulates physiological skin irritation
- Authors:
- Jeon, Byoungjun
Lee, GeonHui
Wufuer, Maierdanjiang
Huang, Yan
Choi, Yunhee
Kim, Sungwan
Choi, Tae Hyun - Abstract:
- Abstract: Current alternatives to animal testing methods for skin irritation evaluation such as reconstructed human epidermis models are not fully representing physiological response caused by skin irritants. Skin irritation is physiologically induced by the dilation and increased permeability of endothelial cells. Thus, our objectives were to mimic physiological skin irritation using a skin-on-a-chip model and compare predictive capacities with a reconstructed human epidermis model to evaluate its effectiveness. To achieve our goals, the skin-on-a-chip model, consisting of three layers representing the epidermal, dermal and endothelial components, was adapted. Cell viability was measured using the OECD TG 439 protocol for test substance evaluation. The tight junctions of endothelial cells were also observed and measured to assess physiological responses to test substances. These parameters were used to physiologically evaluate cell-to-cell interactions induced by test substances and quantify model accuracy, sensitivity, and specificity. Based on in vivo data, the classification accuracy of twenty test substances using a dual-parameter chip model was 80%, which is higher than other methods. Besides, the chip model was more suitable for simulating human skin irritation. Therefore, it is important to note that the dual-parameter chip model possesses an enhanced predictive capacity and could serve as an alternative to animal testing for skin irritation. Highlights: In vitroAbstract: Current alternatives to animal testing methods for skin irritation evaluation such as reconstructed human epidermis models are not fully representing physiological response caused by skin irritants. Skin irritation is physiologically induced by the dilation and increased permeability of endothelial cells. Thus, our objectives were to mimic physiological skin irritation using a skin-on-a-chip model and compare predictive capacities with a reconstructed human epidermis model to evaluate its effectiveness. To achieve our goals, the skin-on-a-chip model, consisting of three layers representing the epidermal, dermal and endothelial components, was adapted. Cell viability was measured using the OECD TG 439 protocol for test substance evaluation. The tight junctions of endothelial cells were also observed and measured to assess physiological responses to test substances. These parameters were used to physiologically evaluate cell-to-cell interactions induced by test substances and quantify model accuracy, sensitivity, and specificity. Based on in vivo data, the classification accuracy of twenty test substances using a dual-parameter chip model was 80%, which is higher than other methods. Besides, the chip model was more suitable for simulating human skin irritation. Therefore, it is important to note that the dual-parameter chip model possesses an enhanced predictive capacity and could serve as an alternative to animal testing for skin irritation. Highlights: In vitro skin irritation assessment method using a dual-parameter chip model has been developed and evaluated. Dual-parameter (cell viability and tight junction) can distinguish between irritants and nonirritants. Predictive values of 80% sensitivity, 80% specificity, and 80% accuracy are achieved. Skin on a chip based model can mimic physiological skin irritation, including endothelial components. Statistical logistic regression models can help improve in vitro alternatives to animal testing. … (more)
- Is Part Of:
- Toxicology in vitro. Volume 68(2020)
- Journal:
- Toxicology in vitro
- Issue:
- Volume 68(2020)
- Issue Display:
- Volume 68, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 68
- Issue:
- 2020
- Issue Sort Value:
- 2020-0068-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-10
- Subjects:
- Organ on a chip -- Skin on a chip -- Skin irritation -- Toxicity -- Reconstructed human epidermis -- Alternative to animal testing
Toxicity testing -- In vitro -- Periodicals
Toxicology -- Periodicals
615.9 - Journal URLs:
- http://www.sciencedirect.com/science/journal/08872333 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.tiv.2020.104955 ↗
- Languages:
- English
- ISSNs:
- 0887-2333
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8873.043400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13916.xml