Simultaneous multislice diffusion-weighted imaging with short tau inversion recovery fat suppression in bone-metastasizing breast cancer. Issue 130 (September 2020)
- Record Type:
- Journal Article
- Title:
- Simultaneous multislice diffusion-weighted imaging with short tau inversion recovery fat suppression in bone-metastasizing breast cancer. Issue 130 (September 2020)
- Main Title:
- Simultaneous multislice diffusion-weighted imaging with short tau inversion recovery fat suppression in bone-metastasizing breast cancer
- Authors:
- Buus, Thomas Winther
Sivesgaard, Kim
Jensen, Anders Bonde
Pedersen, Erik Morre - Abstract:
- Highlights: Multiband DWI reduces scan time of whole-body DWI in bone-metastatic breast cancer. Multiband DWI provides image quality similar to conventional DWI. ADC values from multiband DWI are slightly lower than conventional DWI. Abstract: Purpose: To compare image quality and ADC values of simultaneous multislice diffusion-weighted imaging (mb-DWI) with that of conventional DWI (c-DWI) using short tau inversion recovery fat saturation (STIR) in women with bone-metastasizing breast cancer. Method: c-DWI and mb-DWI were acquired at 1.5 T in 23 breast cancer patients from skull base to mid thighs. mb-DWI was compared to c-DWI in terms of subjective image quality, artefacts and bone metastasis lesion conspicuity assessed on a 5-point Likert scale. ADC values of different organs as well as bone metastasis ADC values were compared between c-DWI and mb-DWI. Results: mb-DWI reduced scan time by 48 % compared with c-DWI (1 min 58 s vs. 3 min 45 s per station). mb-DWI provided similar subjective image quality (3.8 vs. 3.7, p = 0.70), number of artefacts (50 vs. 56), severity of these (4.6 vs. 4.7, p = 0.11), and lesion conspicuity (4.2 vs. 4.4, p = 0.31) compared to c-DWI. mb-DWI showed lower mean ADC values in liver (0.5 × 10 −3 mm 2 /s vs. 0.7 × 10 −3 mm 2 /s, p = 0.002) and erector spine muscle (1.3 × 10 −3 mm 2 /s vs. 1.5 × 10 −3 mm 2 /s, p < 0.001). Bone metastasis ADC values from mb-DWI were 6.4 % lower than c-DWI (95 % confidence interval: 5.4%–7.4%, p < 0.001).Highlights: Multiband DWI reduces scan time of whole-body DWI in bone-metastatic breast cancer. Multiband DWI provides image quality similar to conventional DWI. ADC values from multiband DWI are slightly lower than conventional DWI. Abstract: Purpose: To compare image quality and ADC values of simultaneous multislice diffusion-weighted imaging (mb-DWI) with that of conventional DWI (c-DWI) using short tau inversion recovery fat saturation (STIR) in women with bone-metastasizing breast cancer. Method: c-DWI and mb-DWI were acquired at 1.5 T in 23 breast cancer patients from skull base to mid thighs. mb-DWI was compared to c-DWI in terms of subjective image quality, artefacts and bone metastasis lesion conspicuity assessed on a 5-point Likert scale. ADC values of different organs as well as bone metastasis ADC values were compared between c-DWI and mb-DWI. Results: mb-DWI reduced scan time by 48 % compared with c-DWI (1 min 58 s vs. 3 min 45 s per station). mb-DWI provided similar subjective image quality (3.8 vs. 3.7, p = 0.70), number of artefacts (50 vs. 56), severity of these (4.6 vs. 4.7, p = 0.11), and lesion conspicuity (4.2 vs. 4.4, p = 0.31) compared to c-DWI. mb-DWI showed lower mean ADC values in liver (0.5 × 10 −3 mm 2 /s vs. 0.7 × 10 −3 mm 2 /s, p = 0.002) and erector spine muscle (1.3 × 10 −3 mm 2 /s vs. 1.5 × 10 −3 mm 2 /s, p < 0.001). Bone metastasis ADC values from mb-DWI were 6.4 % lower than c-DWI (95 % confidence interval: 5.4%–7.4%, p < 0.001). Conclusions: mb-DWI provides similar subjective image quality to c-DWI with the same level of artefacts. Although bone metastasis ADC values were lower, mb-DWI can substantially reduce scan times of whole-body DWI in women with bone-metastasizing breast cancer. … (more)
- Is Part Of:
- European journal of radiology. Issue 130(2020)
- Journal:
- European journal of radiology
- Issue:
- Issue 130(2020)
- Issue Display:
- Volume 130, Issue 130 (2020)
- Year:
- 2020
- Volume:
- 130
- Issue:
- 130
- Issue Sort Value:
- 2020-0130-0130-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-09
- Subjects:
- DWID iffusion-weighted imaging -- MB Multiband -- EPI Echo planar imaging -- DWIBS Diffusion-weighted imaging with background body signal suppression -- STIR Short tau inversion recovery -- SPAIR Spectral attenuated inversion recovery -- mb-DWI Multiband diffusion-weighted imaging -- c-DWI Conventional diffusion-weighted imaging -- TR Repetition Time -- TE Echo Time -- TII nversion time -- TSE Turbo spin echo -- ROI Region of interest -- SD Standard deviation -- CI Confidence interval
Diffusion magnetic resonance imaging -- Whole body imaging -- Breast neoplasms -- Bone marrow diseases
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2020.109142 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13908.xml