Carotid and cerebrovascular dual-energy computed tomography angiography: Optimization of window settings for virtual monoenergetic imaging reconstruction. Issue 130 (September 2020)
- Record Type:
- Journal Article
- Title:
- Carotid and cerebrovascular dual-energy computed tomography angiography: Optimization of window settings for virtual monoenergetic imaging reconstruction. Issue 130 (September 2020)
- Main Title:
- Carotid and cerebrovascular dual-energy computed tomography angiography: Optimization of window settings for virtual monoenergetic imaging reconstruction
- Authors:
- D'Angelo, Tommaso
Lenga, Lukas
Arendt, Christophe T.
Bucher, Andreas M.
Peterke, Julia L.
Caruso, Damiano
Mazziotti, Silvio
Ascenti, Giorgio
Blandino, Alfredo
Othman, Ahmed E.
Martin, Simon S.
Albrecht, Moritz H.
Bodelle, Boris
Vogl, Thomas J.
Wichmann, Julian L. - Abstract:
- Highlights: Virtual monoenergetic images (VMI) can be calculated from dual-energy CT angiography (DE-CTA). VMI reconstructions can drastically improve vessel contrast, but require dedicated windowing. Both subjectively best (B–W/L) and objectively best (O–W/L) window settings were assessed. Ideal window settings for VMI and novel VMI + were significantly higher than for standard DE-CTA. Readers subjectively prefered M40+ reconstructions regarding overall image quality. Abstract: Purpose: Dedicated post-processing of dual-energy computed tomography angiography (DE-CTA) datasets has been shown to allow for increased vascular contrast. The goal of our study was to define optimal window settings for displaying virtual monoenergetic images (VMI) reconstructed from dual-energy carotid and cerebrovascular DE-CTA. Methods: Fifty-seven patients who underwent clinically-indicated carotid and cerebrovascular third-generation dual-source DE-CTA were retrospectively evaluated. Standard linearly-blended (M_0.6), 70-keV traditional VMI (M70), and 40-keV noise-optimized VMI (M40+) reconstructions were analyzed. For M70 and M40+ datasets, the subjectively best window setting (width and level, B–W/L) was independently determined by two observers and subsequently related with aortic arch attenuation to calculate optimized values (O–W/L) using linear regression. Subjective evaluation of image quality (IQ) between W/L settings were assessed by two additional readers. Repeated measures analysisHighlights: Virtual monoenergetic images (VMI) can be calculated from dual-energy CT angiography (DE-CTA). VMI reconstructions can drastically improve vessel contrast, but require dedicated windowing. Both subjectively best (B–W/L) and objectively best (O–W/L) window settings were assessed. Ideal window settings for VMI and novel VMI + were significantly higher than for standard DE-CTA. Readers subjectively prefered M40+ reconstructions regarding overall image quality. Abstract: Purpose: Dedicated post-processing of dual-energy computed tomography angiography (DE-CTA) datasets has been shown to allow for increased vascular contrast. The goal of our study was to define optimal window settings for displaying virtual monoenergetic images (VMI) reconstructed from dual-energy carotid and cerebrovascular DE-CTA. Methods: Fifty-seven patients who underwent clinically-indicated carotid and cerebrovascular third-generation dual-source DE-CTA were retrospectively evaluated. Standard linearly-blended (M_0.6), 70-keV traditional VMI (M70), and 40-keV noise-optimized VMI (M40+) reconstructions were analyzed. For M70 and M40+ datasets, the subjectively best window setting (width and level, B–W/L) was independently determined by two observers and subsequently related with aortic arch attenuation to calculate optimized values (O–W/L) using linear regression. Subjective evaluation of image quality (IQ) between W/L settings were assessed by two additional readers. Repeated measures analysis of variance were performed to compare W/L settings and IQ indices between M_0.6, M70, and M40 + . Results: B–W/L and O–W/L for M70 were 580/210 and 560/200, and for M40+ were 1630/570 and 1560/550, respectively, higher than standard DE-CTA W/L settings (450/100). Highest subjective scores were observed for M40+ regarding overall IQ (all p < 0.001). Conclusion: Application of O–W/L settings is mandatory to optimize subjective IQ of VMI reconstructions of DE-CTA. … (more)
- Is Part Of:
- European journal of radiology. Issue 130(2020)
- Journal:
- European journal of radiology
- Issue:
- Issue 130(2020)
- Issue Display:
- Volume 130, Issue 130 (2020)
- Year:
- 2020
- Volume:
- 130
- Issue:
- 130
- Issue Sort Value:
- 2020-0130-0130-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-09
- Subjects:
- Carotid disease -- Dual-energy -- Computed tomography -- Computed tomography angiography -- Image postprocessing
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2020.109166 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13908.xml