Validation of MRI‐VLFF for the non‐invasive measurement of steatosis in children. Issue 4 (26th July 2020)
- Record Type:
- Journal Article
- Title:
- Validation of MRI‐VLFF for the non‐invasive measurement of steatosis in children. Issue 4 (26th July 2020)
- Main Title:
- Validation of MRI‐VLFF for the non‐invasive measurement of steatosis in children
- Authors:
- Vos, Miriam B.
Castillo‐Leon, Eduardo
Knight‐Scott, Jack
Cleeton, Rebecca
Freeman, Alvin Jay
Frediani, Jennifer K.
Hernandez, Albert
Simoneaux, Stephen F.
Kong, Jun
Farris, Alton Brad
House, Michael J
St. Pierre, Tim - Abstract:
- Summary: Background & Aims: Magnetic resonance‐based steatosis measurement of the liver has become the non‐invasive gold standard; however very few diagnostic thresholds have been independently validated and none in children. This study was designed to validate diagnostic thresholds, assess repeatability and the relationship to histology of a proprietary MRI volumetric liver fat fraction (VLFF) method (HepaFat‐Scan ® ) and magnetic resonance spectroscopy (MRS) proton density fat fraction (PDFF) method. Methods: This cross‐sectional study assesses the diagnostic accuracy of MRI‐VLFF and MRS‐PDFF of 50 children who had a clinically indicated liver biopsy. Twenty‐five children were randomly selected for intra‐examination repeatability. The positive pixel count (PPC) algorithm was used to quantify the area of fat vesicles in the histology. The area under the receiver operating characteristic curve (AUROC) was used to assess the diagnostic accuracy. Bland‐Altman plots were used to compare the methods and examine the repeatability. Results: The MRI‐VLFF ranged from 0.3% to 35.4% and the MRS‐PDFF ranged from 0.5% to 36.9%. Based on histopathological analysis, the diagnostic accuracy of MRI‐VLFF for steatosis detection (grade 0 vs 1‐3) showed an AUROC of 0.95 (95% confidence interval [CI]: 0.89‐1.00), whereas MRI‐PDFF classified grade 0 vs 1‐3 showed an AUROC of 0.96 (95% CI: 0.91‐1.00). The repeatability coefficients were 1.8 (±0.5) % for MRI‐VLFF and 2.1 (±0.6) % for MRS‐PDFF.Summary: Background & Aims: Magnetic resonance‐based steatosis measurement of the liver has become the non‐invasive gold standard; however very few diagnostic thresholds have been independently validated and none in children. This study was designed to validate diagnostic thresholds, assess repeatability and the relationship to histology of a proprietary MRI volumetric liver fat fraction (VLFF) method (HepaFat‐Scan ® ) and magnetic resonance spectroscopy (MRS) proton density fat fraction (PDFF) method. Methods: This cross‐sectional study assesses the diagnostic accuracy of MRI‐VLFF and MRS‐PDFF of 50 children who had a clinically indicated liver biopsy. Twenty‐five children were randomly selected for intra‐examination repeatability. The positive pixel count (PPC) algorithm was used to quantify the area of fat vesicles in the histology. The area under the receiver operating characteristic curve (AUROC) was used to assess the diagnostic accuracy. Bland‐Altman plots were used to compare the methods and examine the repeatability. Results: The MRI‐VLFF ranged from 0.3% to 35.4% and the MRS‐PDFF ranged from 0.5% to 36.9%. Based on histopathological analysis, the diagnostic accuracy of MRI‐VLFF for steatosis detection (grade 0 vs 1‐3) showed an AUROC of 0.95 (95% confidence interval [CI]: 0.89‐1.00), whereas MRI‐PDFF classified grade 0 vs 1‐3 showed an AUROC of 0.96 (95% CI: 0.91‐1.00). The repeatability coefficients were 1.8 (±0.5) % for MRI‐VLFF and 2.1 (±0.6) % for MRS‐PDFF. There was no bias between MRI‐VLFF and PPC steatosis. To allow direct comparison, MRS‐PDFF was converted to MRS‐VLFF. Small, but significant biases were measured between PPC steatosis and MRS‐VLFF (−1.38%) and between MRI‐VLFF and MRS‐VLFF (−1.39%). Conclusions: Both MRI‐VLFF and MRS‐PDFF accurately estimated hepatic steatosis in children with excellent agreement with the histological assessment. … (more)
- Is Part Of:
- GastroHep. Volume 2:Issue 4(2020)
- Journal:
- GastroHep
- Issue:
- Volume 2:Issue 4(2020)
- Issue Display:
- Volume 2, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 2
- Issue:
- 4
- Issue Sort Value:
- 2020-0002-0004-0000
- Page Start:
- 171
- Page End:
- 180
- Publication Date:
- 2020-07-26
- Subjects:
- Gastroenterology -- Periodicals
Hepatology -- Periodicals
616.33 - Journal URLs:
- https://onlinelibrary.wiley.com/loi/14781239 ↗
https://www.hindawi.com/journals/ghep/ ↗ - DOI:
- 10.1002/ygh2.410 ↗
- Languages:
- English
- ISSNs:
- 2689-3711
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4089.036000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13894.xml