An optimized protocol for high precision measurement of 87Sr/86Sr using a Neptune Plus multi-collector inductively coupled plasma mass spectrometer: evaluation of different cone combinations for Sr isotope determination. Issue 32 (5th August 2020)
- Record Type:
- Journal Article
- Title:
- An optimized protocol for high precision measurement of 87Sr/86Sr using a Neptune Plus multi-collector inductively coupled plasma mass spectrometer: evaluation of different cone combinations for Sr isotope determination. Issue 32 (5th August 2020)
- Main Title:
- An optimized protocol for high precision measurement of 87Sr/86Sr using a Neptune Plus multi-collector inductively coupled plasma mass spectrometer: evaluation of different cone combinations for Sr isotope determination
- Authors:
- Zhou, Ting
Qi, Liang
Fan, Haifeng
Yin, Runsheng - Abstract:
- Abstract : The effect of sample gas flow rate on the β 88 Sr/ 86 Sr of the two cone combinations. Abstract : Measuring 87 Sr/ 86 Sr ratios with MC-ICP-MS is a straightforward technique due to its fast sample introduction. However, excellent accuracy and precision cannot be easily achieved unless careful optimization of plasma running conditions and evaluation of instrumental mass bias are conducted. Here, we developed an optimized protocol for measuring 87 Sr/ 86 Sr ratios using a modified cone arrangement (H skimmer cone + Jet sample cone) by carefully examining the effects of plasma working conditions on the performance of Sr isotope analysis with a Neptune Plus™ MC-ICP-MS. The modified cone arrangement significantly enhanced the Sr signal sensitivities by a factor of 2, compared to the standard cone arrangement (H skimmer cone + standard sample cone). For both cone arrangements, the mass bias of Sr isotopes fits the standard exponential law under optimal conditions. However, at non-optimum sample gas flow rates, the corrected 87 Sr/ 86 Sr ratios deviated from the reference value, and thus non-linear mass bias was observed. Such mass bias could not be corrected using the standard exponential law. This observation cautioned researchers analyzing Sr ratios at optimized sample gas flow rates when using MC-ICP-MS. With further evaluation of the sample concentration, integration time and interference element correction, 87 Sr/ 86 Sr ratio analysis with high accuracy andAbstract : The effect of sample gas flow rate on the β 88 Sr/ 86 Sr of the two cone combinations. Abstract : Measuring 87 Sr/ 86 Sr ratios with MC-ICP-MS is a straightforward technique due to its fast sample introduction. However, excellent accuracy and precision cannot be easily achieved unless careful optimization of plasma running conditions and evaluation of instrumental mass bias are conducted. Here, we developed an optimized protocol for measuring 87 Sr/ 86 Sr ratios using a modified cone arrangement (H skimmer cone + Jet sample cone) by carefully examining the effects of plasma working conditions on the performance of Sr isotope analysis with a Neptune Plus™ MC-ICP-MS. The modified cone arrangement significantly enhanced the Sr signal sensitivities by a factor of 2, compared to the standard cone arrangement (H skimmer cone + standard sample cone). For both cone arrangements, the mass bias of Sr isotopes fits the standard exponential law under optimal conditions. However, at non-optimum sample gas flow rates, the corrected 87 Sr/ 86 Sr ratios deviated from the reference value, and thus non-linear mass bias was observed. Such mass bias could not be corrected using the standard exponential law. This observation cautioned researchers analyzing Sr ratios at optimized sample gas flow rates when using MC-ICP-MS. With further evaluation of the sample concentration, integration time and interference element correction, 87 Sr/ 86 Sr ratio analysis with high accuracy and precision was achieved. Excellent results of the reference materials were obtained using the optimized protocol. Compared to the classical TIMS technique, our method is comparable in precision (∼8 × 10 −6, 2SE) but much faster in operation (14 minutes per analysis), and therefore is a technical advance in Sr isotope geochemistry. … (more)
- Is Part Of:
- Analytical methods. Volume 12:Issue 32(2020)
- Journal:
- Analytical methods
- Issue:
- Volume 12:Issue 32(2020)
- Issue Display:
- Volume 12, Issue 32 (2020)
- Year:
- 2020
- Volume:
- 12
- Issue:
- 32
- Issue Sort Value:
- 2020-0012-0032-0000
- Page Start:
- 4089
- Page End:
- 4096
- Publication Date:
- 2020-08-05
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d0ay00845a ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13887.xml