Repeatability of ultrasound examination of the optic nerve sheath diameter in the adult cat: comparison between healthy cats and cats suffering from presumed intracranial hypertension. Issue 10 (October 2020)
- Record Type:
- Journal Article
- Title:
- Repeatability of ultrasound examination of the optic nerve sheath diameter in the adult cat: comparison between healthy cats and cats suffering from presumed intracranial hypertension. Issue 10 (October 2020)
- Main Title:
- Repeatability of ultrasound examination of the optic nerve sheath diameter in the adult cat: comparison between healthy cats and cats suffering from presumed intracranial hypertension
- Authors:
- Evangelisti, Maria Antonietta
Carta, Giovanni
Burrai, Giovanni P
Pinna Parpaglia, Maria Luisa
Cubeddu, Francesca
Ballocco, Isabella
Puggioni, Antonella
Manunta, Maria Lucia - Abstract:
- Objectives: The objectives of this study were to test: (1) the repeatability of ultrasonographic examination of the optic nerve sheath diameter (ONSD) in the cat; (2) the association between the ONSD and age, sex and body weight in healthy cats; and (3) the difference in the ONSD between healthy cats and those suffering from presumed intracranial hypertension (ICH). Methods: This study had a prospective, blinded, observational cross-sectional study design. Two groups of animals were considered: healthy cats (group A) and cats with a diagnosis of presumed ICH (group B). The ONSD was evaluated, measured and compared between the two groups via an ultrasonographic transpalpebral approach. Repeatability of the procedure was evaluated through the intraclass correlation coefficient (ICC). Data were statistically compared using the Student's t -test and linear regression analysis. Results: A strong inter- and intraobserver ICC indicating good repeatability was observed. The interobserver ICC was 0.965 ( P <0.05) for the right eye and 0.956 ( P <0.05) for the left eye. The intraobserver ICC was 0.988 ( P <0.05) and 0.984 ( P <0.05) for the right and left eyes, respectively. In healthy cats the mean ± SD ONSD was 1.23 ± 0.11 mm (range 1–1.47 mm) and 1.23 ± 0.10 (range 1–1.4 mm) for right and left eyes, respectively. The ONSD was not related to sex or weight; a weak relationship was observed with age. In group B, the mean ONSD was 1.68 ± 0.13 mm (range 1.5–1.9 mm) andObjectives: The objectives of this study were to test: (1) the repeatability of ultrasonographic examination of the optic nerve sheath diameter (ONSD) in the cat; (2) the association between the ONSD and age, sex and body weight in healthy cats; and (3) the difference in the ONSD between healthy cats and those suffering from presumed intracranial hypertension (ICH). Methods: This study had a prospective, blinded, observational cross-sectional study design. Two groups of animals were considered: healthy cats (group A) and cats with a diagnosis of presumed ICH (group B). The ONSD was evaluated, measured and compared between the two groups via an ultrasonographic transpalpebral approach. Repeatability of the procedure was evaluated through the intraclass correlation coefficient (ICC). Data were statistically compared using the Student's t -test and linear regression analysis. Results: A strong inter- and intraobserver ICC indicating good repeatability was observed. The interobserver ICC was 0.965 ( P <0.05) for the right eye and 0.956 ( P <0.05) for the left eye. The intraobserver ICC was 0.988 ( P <0.05) and 0.984 ( P <0.05) for the right and left eyes, respectively. In healthy cats the mean ± SD ONSD was 1.23 ± 0.11 mm (range 1–1.47 mm) and 1.23 ± 0.10 (range 1–1.4 mm) for right and left eyes, respectively. The ONSD was not related to sex or weight; a weak relationship was observed with age. In group B, the mean ONSD was 1.68 ± 0.13 mm (range 1.5–1.9 mm) and 1.61 ± 0.15 mm (range 1.4–1.9 mm) for the right and left eyes, respectively. In group B, the ONSD was statistically significantly larger than in group A, the healthy cats ( P <0.001). Conclusions and relevance: The transpalpebral ultrasonographic technique is a non-invasive, feasible and reproducible method to measure ONSD both in healthy cats and in cats suffering from suspected ICH. … (more)
- Is Part Of:
- Journal of feline medicine and surgery. Volume 22:Issue 10(2020)
- Journal:
- Journal of feline medicine and surgery
- Issue:
- Volume 22:Issue 10(2020)
- Issue Display:
- Volume 22, Issue 10 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 10
- Issue Sort Value:
- 2020-0022-0010-0000
- Page Start:
- 959
- Page End:
- 965
- Publication Date:
- 2020-10
- Subjects:
- Intracranial hypertension -- optic nerve sheath diameter -- ultrasound -- emergency
Cats -- Diseases -- Periodicals
Cats -- Surgery -- Periodicals
636.8089 - Journal URLs:
- http://jfm.sagepub.com/ ↗
http://www.sciencedirect.com/science/journal/1098612X ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1098612X19898006 ↗
- Languages:
- English
- ISSNs:
- 1098-612X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4983.933000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13887.xml