A motion prediction confidence estimation framework for prediction‐based radiotherapy gating. Issue 8 (4th June 2020)
- Record Type:
- Journal Article
- Title:
- A motion prediction confidence estimation framework for prediction‐based radiotherapy gating. Issue 8 (4th June 2020)
- Main Title:
- A motion prediction confidence estimation framework for prediction‐based radiotherapy gating
- Authors:
- Ginn, John S.
Low, Daniel A.
Lamb, James M.
Ruan, Dan - Abstract:
- Abstract : Purpose: Motion prediction can compensate for latency in image‐guided radiotherapy and has been an active area of research. However, motion predictions are subject to error and variations. We have developed and evaluated a novel motion prediction confidence estimation framework to improve the efficacy and robustness of prediction‐based radiotherapy gating decision‐making. The specific scenario of adaptive gating in magnetic resonance imaging (MRI)‐guided radiotherapy is studied as an example, but the method generalizes to other modalities and motion management setups. Methods: The proposed prediction confidence estimator is based on a generic training/testing paradigm and consists of a weighted combination of three components: the prediction model's goodness of fit, variation in the prediction using a leave‐one‐out process and the velocity of the tracked target. Roughly, these terms quantify respectively the consistency between prediction and the training data, the robustness of model inference, and the stability due to target speed. The weight parameters and the action level in triggering beam‐off decision are optimized. The method is assessed and validated in 8 healthy volunteer and 13 patient studies using a 0.35T MRI‐guided radiotherapy system predicting 0.25–0.33 s ahead. The effect of the action level on the predicted gating decision accuracy, beam‐on positive predictive value (PPV) and median distance between the predicted and ground‐truth target centroidsAbstract : Purpose: Motion prediction can compensate for latency in image‐guided radiotherapy and has been an active area of research. However, motion predictions are subject to error and variations. We have developed and evaluated a novel motion prediction confidence estimation framework to improve the efficacy and robustness of prediction‐based radiotherapy gating decision‐making. The specific scenario of adaptive gating in magnetic resonance imaging (MRI)‐guided radiotherapy is studied as an example, but the method generalizes to other modalities and motion management setups. Methods: The proposed prediction confidence estimator is based on a generic training/testing paradigm and consists of a weighted combination of three components: the prediction model's goodness of fit, variation in the prediction using a leave‐one‐out process and the velocity of the tracked target. Roughly, these terms quantify respectively the consistency between prediction and the training data, the robustness of model inference, and the stability due to target speed. The weight parameters and the action level in triggering beam‐off decision are optimized. The method is assessed and validated in 8 healthy volunteer and 13 patient studies using a 0.35T MRI‐guided radiotherapy system predicting 0.25–0.33 s ahead. The effect of the action level on the predicted gating decision accuracy, beam‐on positive predictive value (PPV) and median distance between the predicted and ground‐truth target centroids were evaluated. Statistical significance was evaluated using a paired t ‐test. The tradeoff between these performance metrics and gating duty cycle was assessed. Results: Use of the confidence estimator threshold increased gating accuracy by up to 2.42%, increased PPV by up to 3.00%, and reduced the median centroid distance up to 0.28 mm. The confidence estimator threshold on average increased gating accuracy to 96.5% ( P = 2.08 × 10 −4 ), increased PPV to 96.7% ( P = 1.46 × 10 −5 ), reduced the median centroid distance to 0.54 mm ( P = 1.71 × 10 −5 ) at the cost of reducing the gating duty cycle by 14.3% to 48.5%. Hyperparameter tuning revealed that contrary to intuition, the velocity term offered only minimal performance improvement in some cases but also introduced potential stability issues. The combination of goodness of fit and leave‐one‐out prediction variation provided the most effective confidence estimator, yielding universally better performance in gating decisions. Conclusion: Confidence estimation utilizing prediction model fitness criterion and validation principles can complement prediction methods to guide MRI‐guided radiotherapy gating. Results from both volunteer and patient studies showed improved gating quality. … (more)
- Is Part Of:
- Medical physics. Volume 47:Issue 8(2020)
- Journal:
- Medical physics
- Issue:
- Volume 47:Issue 8(2020)
- Issue Display:
- Volume 47, Issue 8 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 8
- Issue Sort Value:
- 2020-0047-0008-0000
- Page Start:
- 3297
- Page End:
- 3304
- Publication Date:
- 2020-06-04
- Subjects:
- motion prediction -- MRI -- radiotherapy
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.14236 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13889.xml