Development of a stereoscopic CT metal artifact management algorithm using gantry angle tilts for head and neck patients. Issue 8 (7th June 2020)
- Record Type:
- Journal Article
- Title:
- Development of a stereoscopic CT metal artifact management algorithm using gantry angle tilts for head and neck patients. Issue 8 (7th June 2020)
- Main Title:
- Development of a stereoscopic CT metal artifact management algorithm using gantry angle tilts for head and neck patients
- Authors:
- Branco, Daniela
Kry, Stephen
Taylor, Paige
Rong, John
Zhang, Xiaodong
Peterson, Christine
Frank, Steven
Followill, David - Abstract:
- Abstract: Dental amalgams are a common source of artifacts in head and neck (HN) images. Commercial artifact reduction techniques have been offered, but are substantially ineffectual at reducing artifacts from dental amalgams, can produce additional artifacts, provide inaccurate HU information, or require extensive computation time, and thus offer limited clinically utility. The goal of this work was to define and validate a novel algorithm and provide a phantom‐based testing as proof of principle. An initial clinical comparison to a vendor's current solution was also performed. The algorithm uses two‐angled CT scans in order to generate a single image set with minimal artifacts posterior to the metal implants. The algorithm was evaluated using a phantom simulating a HN patient with dental fillings. Baseline (no artifacts) geometrical measurements of the phantom were taken in the anterior–posterior, left–right, and superior–inferior directions and compared to the metal‐corrected images using our algorithm to evaluate possible distortion from application of the algorithm. Mean HU numbers were also compared between the baseline scan and corrected image sets. A similar analysis was performed on the vendor's algorithm for comparison. The algorithm developed in this work successfully preserved the image geometry and HU and corrected the CT metal artifacts in the region posterior to the metal. The average total distortion for all gantry angles in the AP, LR, and SI directions wasAbstract: Dental amalgams are a common source of artifacts in head and neck (HN) images. Commercial artifact reduction techniques have been offered, but are substantially ineffectual at reducing artifacts from dental amalgams, can produce additional artifacts, provide inaccurate HU information, or require extensive computation time, and thus offer limited clinically utility. The goal of this work was to define and validate a novel algorithm and provide a phantom‐based testing as proof of principle. An initial clinical comparison to a vendor's current solution was also performed. The algorithm uses two‐angled CT scans in order to generate a single image set with minimal artifacts posterior to the metal implants. The algorithm was evaluated using a phantom simulating a HN patient with dental fillings. Baseline (no artifacts) geometrical measurements of the phantom were taken in the anterior–posterior, left–right, and superior–inferior directions and compared to the metal‐corrected images using our algorithm to evaluate possible distortion from application of the algorithm. Mean HU numbers were also compared between the baseline scan and corrected image sets. A similar analysis was performed on the vendor's algorithm for comparison. The algorithm developed in this work successfully preserved the image geometry and HU and corrected the CT metal artifacts in the region posterior to the metal. The average total distortion for all gantry angles in the AP, LR, and SI directions was 0.17, 0.12, and 0.14 mm, respectively. The HU measurements showed significant consistency throughout the different reconstructed images when compared to the baseline image sets. The vendor's algorithm also showed no geometrical distortion but performed inferiorly in the HU number analysis compared to our technique. Our novel metal artifact management algorithm, using CT gantry angle tilts, provides a promising technique for clinical management of metal artifacts from dental amalgam. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 21:Issue 8(2020)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 21:Issue 8(2020)
- Issue Display:
- Volume 21, Issue 8 (2020)
- Year:
- 2020
- Volume:
- 21
- Issue:
- 8
- Issue Sort Value:
- 2020-0021-0008-0000
- Page Start:
- 120
- Page End:
- 130
- Publication Date:
- 2020-06-07
- Subjects:
- algorithm -- head and neck -- CT -- metal artifact reduction -- gantry angle
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12922 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13878.xml