Locking Screws With a Threaded Degradable Polymer Collar Reduce Construct Stiffness Over Time. Issue 3 (March 2020)
- Record Type:
- Journal Article
- Title:
- Locking Screws With a Threaded Degradable Polymer Collar Reduce Construct Stiffness Over Time. Issue 3 (March 2020)
- Main Title:
- Locking Screws With a Threaded Degradable Polymer Collar Reduce Construct Stiffness Over Time
- Authors:
- Schultz, Blake J.
Amin, Nirav H.
Mattison, Braden J.
Mir, Hassan R.
Shah, Anjan R.
Cerynik, Douglas L. - Abstract:
- Abstract : Objectives: The stiffness of locking plates provide increased stability for early fracture healing but may limit late interfragmentary motion (IFM) necessary for secondary bone healing. An ideal plating construct would provide early rigidity and late flexibility to optimize bone healing. A novel screw plate construct utilizing locking screws with a degradable polymer locking mechanism is a dynamic option. Methods: Conventional locked plating constructs (group A) were compared with locking screws with a threaded degradable polymer collar before (group B) and after polymer dissolution (group C). Monotonic axial compression, monotonic torsion, cyclic axial load to failure, and IFM at the near and far cortices were tested on synthetic bone models. Results: One-way analysis of variance and post hoc Tukey–Kramer testing demonstrated similar axial stiffness in group A (873 ± 146 N/mm) and B (694 ± 314 N/mm) but significantly less stiffness in group C (379 ± 59 N/mm; F (2, 15) = 9.12, P = 0.003). Groups A and B also had similar IFM, but group C had significantly increased IFM at both the near ( F (2, 15) = 48.66, P = 2.76E-07) and far ( F (2, 15) = 11.78, P = 0.0008) cortices. In cyclic axial load to failure, group A (1593 ± 233 N) and B (1277 ± 141 N) were again similar, but group C was significantly less (912 ± 256 N; F (2, 15) = 15.00, P = 0.0003). All failures were above the 500-N threshold seen in typical weight-bearing restrictions for fracture care. TorsionalAbstract : Objectives: The stiffness of locking plates provide increased stability for early fracture healing but may limit late interfragmentary motion (IFM) necessary for secondary bone healing. An ideal plating construct would provide early rigidity and late flexibility to optimize bone healing. A novel screw plate construct utilizing locking screws with a degradable polymer locking mechanism is a dynamic option. Methods: Conventional locked plating constructs (group A) were compared with locking screws with a threaded degradable polymer collar before (group B) and after polymer dissolution (group C). Monotonic axial compression, monotonic torsion, cyclic axial load to failure, and IFM at the near and far cortices were tested on synthetic bone models. Results: One-way analysis of variance and post hoc Tukey–Kramer testing demonstrated similar axial stiffness in group A (873 ± 146 N/mm) and B (694 ± 314 N/mm) but significantly less stiffness in group C (379 ± 59 N/mm; F (2, 15) = 9.12, P = 0.003). Groups A and B also had similar IFM, but group C had significantly increased IFM at both the near ( F (2, 15) = 48.66, P = 2.76E-07) and far ( F (2, 15) = 11.78, P = 0.0008) cortices. In cyclic axial load to failure, group A (1593 ± 233 N) and B (1277 ± 141 N) were again similar, but group C was significantly less (912 ± 256 N; F (2, 15) = 15.00, P = 0.0003). All failures were above the 500-N threshold seen in typical weight-bearing restrictions for fracture care. Torsional stiffness demonstrated significant differences between all groups ( F (2, 15) = 106.64, P = 1.4E-09). Conclusions: Use of locking plates with a degradable polymer collar show potential for in vitro construct dynamization. Future in vivo studies are warranted to assess performance under combined loading and the effects of decreasing construct stiffness during the course of bony healing. Abstract : Supplemental Digital Content is Available in the Text. … (more)
- Is Part Of:
- Journal of orthopaedic trauma. Volume 34:Issue 3(2020)
- Journal:
- Journal of orthopaedic trauma
- Issue:
- Volume 34:Issue 3(2020)
- Issue Display:
- Volume 34, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 34
- Issue:
- 3
- Issue Sort Value:
- 2020-0034-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-03
- Subjects:
- locking screws -- degradable polymer collar -- construct stiffness -- interfragmentary motion -- micromotion
Orthopedics -- Periodicals
Wounds and injuries -- Periodicals
Orthopedics -- Periodicals
Wounds and Injuries -- therapy -- Periodicals
Periodicals
617.47044 - Journal URLs:
- http://journals.lww.com/jorthotrauma/pages/default.aspx ↗
http://www.jorthotrauma.com ↗
http://cufts2.lib.sfu.ca/CJDB/BVAS/journal/149202 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00005131-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BOT.0000000000001664 ↗
- Languages:
- English
- ISSNs:
- 0890-5339
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.675000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13881.xml