Feasibility of real‐time motion tracking using cine MRI during MR‐guided radiation therapy for abdominal targets. Issue 8 (3rd June 2020)
- Record Type:
- Journal Article
- Title:
- Feasibility of real‐time motion tracking using cine MRI during MR‐guided radiation therapy for abdominal targets. Issue 8 (3rd June 2020)
- Main Title:
- Feasibility of real‐time motion tracking using cine MRI during MR‐guided radiation therapy for abdominal targets
- Authors:
- Keiper, Timothy D.
Tai, An
Chen, Xinfeng
Paulson, Eric
Lathuilière, Fabienne
Bériault, Silvain
Hébert, François
Cooper, David T.
Lachaine, Martin
Li, X. Allen - Abstract:
- Abstract : Purpose: Real‐time high soft‐tissue contrast magnetic resonance imaging (MRI) from the MR‐Linac offers the best opportunity for accurate motion tracking during radiation therapy delivery via high‐frequency two‐dimensional (2D) cine imaging. This work investigates the efficacy of real‐time organ motion tracking based on the registration of MRI acquired on MR‐Linac. Methods: Algorithms based on image intensity were developed to determine the three‐dimensional (3D) translation of abdominal targets. 2D and 3D abdominal MRIs were acquired for 10 healthy volunteers using a high‐field MR‐Linac. For each volunteer, 3D respiration‐gated T2 and 2D T2/T1‐weighted cine in sagittal, coronal, and axial planes with a planar temporal resolution of 0.6 for 60 s was captured. Datasets were also collected on MR‐compatible physical and virtual four‐dimensional (4D) motion phantoms. Target contours for the liver and pancreas from the 3D T2 were populated to the cine and assumed as the ground‐truth motion. We performed image registration using a research software to track the target 3D motion. Standard deviations of the error (SDE) between the ground‐truth and tracking were analyzed. Results: Algorithms using a research software were demonstrated to be capable of tracking arbitrary targets in the abdomen at 5 Hz with an overall accuracy of 0.6 mm in phantom studies and 2.1 mm in volunteers. However, this value is subject to patient‐specific considerations, namely motion amplitude.Abstract : Purpose: Real‐time high soft‐tissue contrast magnetic resonance imaging (MRI) from the MR‐Linac offers the best opportunity for accurate motion tracking during radiation therapy delivery via high‐frequency two‐dimensional (2D) cine imaging. This work investigates the efficacy of real‐time organ motion tracking based on the registration of MRI acquired on MR‐Linac. Methods: Algorithms based on image intensity were developed to determine the three‐dimensional (3D) translation of abdominal targets. 2D and 3D abdominal MRIs were acquired for 10 healthy volunteers using a high‐field MR‐Linac. For each volunteer, 3D respiration‐gated T2 and 2D T2/T1‐weighted cine in sagittal, coronal, and axial planes with a planar temporal resolution of 0.6 for 60 s was captured. Datasets were also collected on MR‐compatible physical and virtual four‐dimensional (4D) motion phantoms. Target contours for the liver and pancreas from the 3D T2 were populated to the cine and assumed as the ground‐truth motion. We performed image registration using a research software to track the target 3D motion. Standard deviations of the error (SDE) between the ground‐truth and tracking were analyzed. Results: Algorithms using a research software were demonstrated to be capable of tracking arbitrary targets in the abdomen at 5 Hz with an overall accuracy of 0.6 mm in phantom studies and 2.1 mm in volunteers. However, this value is subject to patient‐specific considerations, namely motion amplitude. Calculation times of < 50 ms provide a pathway of real‐time motion tracking integration. A major challenge in using 2D cine MRI to track the target is handling the full 3D motion of the target. Conclusions: Feasibility to track organ motion using intensity‐based registration of MRIs was demonstrated for abdominal targets. Tracking accuracy of about 2 mm was achieved for the motion of the liver and pancreatic head for typical patient motion. Further development is ongoing to improve the tracking algorithm for large and complex motions. … (more)
- Is Part Of:
- Medical physics. Volume 47:Issue 8(2020)
- Journal:
- Medical physics
- Issue:
- Volume 47:Issue 8(2020)
- Issue Display:
- Volume 47, Issue 8 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 8
- Issue Sort Value:
- 2020-0047-0008-0000
- Page Start:
- 3554
- Page End:
- 3566
- Publication Date:
- 2020-06-03
- Subjects:
- abdominal organ motion -- motion tracking with cine MRI -- MRI‐guided radiation therapy
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.14230 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13880.xml