A collision prediction framework for noncoplanar radiotherapy planning and delivery. Issue 8 (19th June 2020)
- Record Type:
- Journal Article
- Title:
- A collision prediction framework for noncoplanar radiotherapy planning and delivery. Issue 8 (19th June 2020)
- Main Title:
- A collision prediction framework for noncoplanar radiotherapy planning and delivery
- Authors:
- Islam, Naveed
Kilian‐Meneghin, Josh
deBoer, Steven
Podgorsak, Matthew - Abstract:
- Abstract: Purpose: Noncoplanar radiotherapy can provide significant dosimetric benefits. However, clinical implementation of such techniques is not fully realized, partially due to the absence of a collision prediction tool integrated into the clinical workflow. In this work, the feasibility of developing a collision prediction system (CPS) suitable for integration into clinical practice has been investigated. Methods: The CPS is based on a geometric model of the Linear Accelerator (Linac), and patient morphology acquired at the simulator using a combination of the planning CT scan and 3‐D vision camera (Microsoft, Kinect) data. Physical dimensions of Linac components were taken to construct a geometric model. The Linac components include the treatment couch, gantry, and imaging devices. The treatment couch coordinates were determined based on a correspondence among the CT couch top, Linac couch, and the treatment isocenter location. A collision is predicted based on dot products between vectors denoting points in Linac components and patient morphology. Collision test cases were simulated with the CPS and experimentally verified using ArcCheck and Rando phantoms to simulate a patient. Results: For 111 collision test cases, the sensitivity and specificity of the CPS model were calculated to be 0.95 and 1.00, respectively. The CPS predicted collision states that left conservative margins, as designed, relative to actual collision locations. The average difference between theAbstract: Purpose: Noncoplanar radiotherapy can provide significant dosimetric benefits. However, clinical implementation of such techniques is not fully realized, partially due to the absence of a collision prediction tool integrated into the clinical workflow. In this work, the feasibility of developing a collision prediction system (CPS) suitable for integration into clinical practice has been investigated. Methods: The CPS is based on a geometric model of the Linear Accelerator (Linac), and patient morphology acquired at the simulator using a combination of the planning CT scan and 3‐D vision camera (Microsoft, Kinect) data. Physical dimensions of Linac components were taken to construct a geometric model. The Linac components include the treatment couch, gantry, and imaging devices. The treatment couch coordinates were determined based on a correspondence among the CT couch top, Linac couch, and the treatment isocenter location. A collision is predicted based on dot products between vectors denoting points in Linac components and patient morphology. Collision test cases were simulated with the CPS and experimentally verified using ArcCheck and Rando phantoms to simulate a patient. Results: For 111 collision test cases, the sensitivity and specificity of the CPS model were calculated to be 0.95 and 1.00, respectively. The CPS predicted collision states that left conservative margins, as designed, relative to actual collision locations. The average difference between the predicted and measured collision states was 2.3 cm for lateral couch movements. The predicted couch rotational position for a collision between the gantry and a patient analog differed from actual values on average by 3.8°. The magnitude of these differences is sufficient to account for interfractional patient positioning variations during treatment. Conclusion: The feasibility of developing a CPS using geometric models and standard vector algebra has been investigated. This study outlines a framework for potential clinical implementation of a CPS for noncoplanar radiotherapy. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 21:Issue 8(2020)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 21:Issue 8(2020)
- Issue Display:
- Volume 21, Issue 8 (2020)
- Year:
- 2020
- Volume:
- 21
- Issue:
- 8
- Issue Sort Value:
- 2020-0021-0008-0000
- Page Start:
- 92
- Page End:
- 106
- Publication Date:
- 2020-06-19
- Subjects:
- collision prediction -- noncoplanar radiation therapy -- patient safety -- treatment planning
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12920 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13878.xml