Dosimetry evaluation of the GammaPod stereotactic radiosurgery device based on established AAPM and IAEA protocols. Issue 8 (15th June 2020)
- Record Type:
- Journal Article
- Title:
- Dosimetry evaluation of the GammaPod stereotactic radiosurgery device based on established AAPM and IAEA protocols. Issue 8 (15th June 2020)
- Main Title:
- Dosimetry evaluation of the GammaPod stereotactic radiosurgery device based on established AAPM and IAEA protocols
- Authors:
- Becker, Stewart J.
Culberson, Wesley S.
Poirier, Yannick
Mutaf, Yildirim
Niu, Ying
Nichols, Elizabeth M.
Yi, Byongyong - Abstract:
- Abstract : Purpose: The GammaPod is a novel dedicated prone breast stereotactic radiosurgery (SRS) device recently developed at the University of Maryland Medical Center. This device utilizes multiple rotating Co‐60 sources to create highly conformal dose distributions for breast treatments, including boosts, partial breast irradiation, or presurgery SRS. However, due to its small field sizes and nonstandard geometry, existing calibration protocols cannot be directly applied. In this study, we adapt and implement the American Association of Physicists in Medicine Task Group 21 (TG‐21) and International Atomic Energy Agency (IAEA) Technical Report Series 483 (TRS 483) protocols for reference dose measurements for the GammaPod. This represents the first published dosimetric investigation GammaPod and is meant to serve as a reference to future users commissioning and calibrating these devices. Methods: Reference dose measurements were performed following the TG‐21/IAEA TRS 483 protocols using an ADCL‐calibrated Exradin A1SL thimble chamber in a polymethyl methacrylate (PMMA) breast‐mimicking phantom. Monte Carlo calculations and measurements were also performed in water to determine chamber‐specific k PMMA Q m s r, Q 0 f msr, f ref quality conversion factor converting reference field size (fref ) to machine‐specific field sizes (fmsr ) (25‐mm) as well as k PMMA f clin, f msr, the conversion factor from the (fmsr ) to the clinical field size (fclin ) (15mm). Verification wasAbstract : Purpose: The GammaPod is a novel dedicated prone breast stereotactic radiosurgery (SRS) device recently developed at the University of Maryland Medical Center. This device utilizes multiple rotating Co‐60 sources to create highly conformal dose distributions for breast treatments, including boosts, partial breast irradiation, or presurgery SRS. However, due to its small field sizes and nonstandard geometry, existing calibration protocols cannot be directly applied. In this study, we adapt and implement the American Association of Physicists in Medicine Task Group 21 (TG‐21) and International Atomic Energy Agency (IAEA) Technical Report Series 483 (TRS 483) protocols for reference dose measurements for the GammaPod. This represents the first published dosimetric investigation GammaPod and is meant to serve as a reference to future users commissioning and calibrating these devices. Methods: Reference dose measurements were performed following the TG‐21/IAEA TRS 483 protocols using an ADCL‐calibrated Exradin A1SL thimble chamber in a polymethyl methacrylate (PMMA) breast‐mimicking phantom. Monte Carlo calculations and measurements were also performed in water to determine chamber‐specific k PMMA Q m s r, Q 0 f msr, f ref quality conversion factor converting reference field size (fref ) to machine‐specific field sizes (fmsr ) (25‐mm) as well as k PMMA f clin, f msr, the conversion factor from the (fmsr ) to the clinical field size (fclin ) (15mm). Verification was performed using the thermoluminescent dosimeter remote monitoring service from the Imaging and Radiation Oncology Core (IROC) in Houston, TX. Results: The (fref ) to (fmsr ) chamber‐specific factor k PMMA Q m s r, Q 0 f msr, f ref was 0.992 while the (fmsr ) to (fclin ) chamber‐specific k PMMA f clin, f msr factor was 1.014. The radiation absorbed dose to water measured in the PMMA phantom based on the TG‐21/IAEA TRS 483 formalism agreed with IROC values to within 1% and 2% for the 25‐ and 15‐mm collimators, respectively. Conclusion: We successfully implemented the TG‐21 and TRS 483 reference dosimetry protocols for the GammaPod. These results show agreement between measurements performed with different reference dosimetry protocols and independent thermoluminescent measurements. … (more)
- Is Part Of:
- Medical physics. Volume 47:Issue 8(2020)
- Journal:
- Medical physics
- Issue:
- Volume 47:Issue 8(2020)
- Issue Display:
- Volume 47, Issue 8 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 8
- Issue Sort Value:
- 2020-0047-0008-0000
- Page Start:
- 3614
- Page End:
- 3620
- Publication Date:
- 2020-06-15
- Subjects:
- breast -- cancer -- IAEA TRS 483 -- stereotactic radiosurgery -- TG‐21
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.14197 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13880.xml