Thermal evaluation of a hermetic transcutaneous energy transfer system to power mechanical circulatory support devices in destination therapy. Issue 9 (8th April 2020)
- Record Type:
- Journal Article
- Title:
- Thermal evaluation of a hermetic transcutaneous energy transfer system to power mechanical circulatory support devices in destination therapy. Issue 9 (8th April 2020)
- Main Title:
- Thermal evaluation of a hermetic transcutaneous energy transfer system to power mechanical circulatory support devices in destination therapy
- Authors:
- Au, Shun Long Cyril
McCormick, Daniel
Lever, Nigel
Budgett, David - Abstract:
- Abstract: Current generation left ventricular assist devices (LVADs) are powered by a percutaneous driveline. The high prevalence of driveline infections has motivated the development of transcutaneous energy transfer (TET) systems which eliminate driveline associated complications by wirelessly delivering power across the skin. Destination therapy (DT) requires long‐term reliable operation of the TET electronics suggesting the use of hermetic packaging techniques as used in all other chronically implanted devices. TET coils dissipate heat during operation and in order for the technology to be suitable for patient use, sufficient power must be delivered while maintaining temperatures at levels deemed safe. The heating of a TET system designed for DT which uses hermetic packaging technology was evaluated in silico and in vivo. A numerical model was used to evaluate the temperature of the TET coils. The TET system was fabricated and assessed in vivo using an ovine model. The receiving coil was implanted subcutaneously in a sheep and the transmission coil placed in contact with the skin and concentric to the implanted coil. Temperatures of the system were measured using sensors fixed to the surface of the coils. Numerical modeling indicated that the maximum temperatures of the primary and secondary coil surfaces were 38.13°C and 38.41°C, respectively, when delivering 10 W continuously. Stable temperatures were observed in vivo after 70 minutes and the maximum skin and implantAbstract: Current generation left ventricular assist devices (LVADs) are powered by a percutaneous driveline. The high prevalence of driveline infections has motivated the development of transcutaneous energy transfer (TET) systems which eliminate driveline associated complications by wirelessly delivering power across the skin. Destination therapy (DT) requires long‐term reliable operation of the TET electronics suggesting the use of hermetic packaging techniques as used in all other chronically implanted devices. TET coils dissipate heat during operation and in order for the technology to be suitable for patient use, sufficient power must be delivered while maintaining temperatures at levels deemed safe. The heating of a TET system designed for DT which uses hermetic packaging technology was evaluated in silico and in vivo. A numerical model was used to evaluate the temperature of the TET coils. The TET system was fabricated and assessed in vivo using an ovine model. The receiving coil was implanted subcutaneously in a sheep and the transmission coil placed in contact with the skin and concentric to the implanted coil. Temperatures of the system were measured using sensors fixed to the surface of the coils. Numerical modeling indicated that the maximum temperatures of the primary and secondary coil surfaces were 38.13°C and 38.41°C, respectively, when delivering 10 W continuously. Stable temperatures were observed in vivo after 70 minutes and the maximum skin and implant surface temperatures were 37.73°C and 38.31°C, respectively. This study showed that a hermetic, chronically implantable TET system is thermally safe when continuously delivering 10 W of power, sufficient to power modern LVADs. … (more)
- Is Part Of:
- Artificial organs. Volume 44:Issue 9(2020)
- Journal:
- Artificial organs
- Issue:
- Volume 44:Issue 9(2020)
- Issue Display:
- Volume 44, Issue 9 (2020)
- Year:
- 2020
- Volume:
- 44
- Issue:
- 9
- Issue Sort Value:
- 2020-0044-0009-0000
- Page Start:
- 955
- Page End:
- 967
- Publication Date:
- 2020-04-08
- Subjects:
- chronic implantation -- destination therapy -- hermeticity -- thermal safety -- transcutaneous energy transfer
Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1525-1594 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=aor ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/aor.13679 ↗
- Languages:
- English
- ISSNs:
- 0160-564X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1735.052000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13882.xml