Quantitative determination of leukocyte esterase with a paper-based device. Issue 45 (21st July 2020)
- Record Type:
- Journal Article
- Title:
- Quantitative determination of leukocyte esterase with a paper-based device. Issue 45 (21st July 2020)
- Main Title:
- Quantitative determination of leukocyte esterase with a paper-based device
- Authors:
- Ho, Mei-Lin
Liu, Wei-Fang
Tseng, Hsin-Yi
Yeh, Yu-Tzu
Tseng, Wei-Ting
Chou, Yin-Yu
Huang, Xin-Ru
Hsu, Hung-Cheng
Ho, Li-Ing
Pan, Sheng-Wei - Abstract:
- Abstract : A novel chemiresistive method for quantitative determination of leukocyte esterase. Abstract : The commercially-available colorimetric urine dipstic for the early detection of urinary tract infection (UTI) has several limitations. The quantitative determination of urinary leukocyte esterase (LE) for predicting UTI remains uncertain. This study presents a paper-based analytical device to detect LE (LE-PAD) as a point-of-care quantitative test for UTI. The LE-PAD is composed of a coating of mixed 3-( N -tosyl-L-alaninyloxy)-5-phenylpyrrole (PE) and 1-diazo-2-naphthol-4-sulfonic acid (DAS) deposited onto a silver conducting film (Ag film). The LE/urine reacts with the PE and DAS, and the resulting products in turn react with the silver coating, causing a change in resistivity. The quantitative calibration curve was established in this study and has been used to analyse urine samples from inpatients with urinary catheters ( n = 21). The results revealed that the level of LE determined by LE-PADs was predictive of UTI diagnosis with an area under the receiver operating characteristic curve of 0.875 (95% confidence interval, 0.704–1.000). Using an appropriate cut-off value, the sensitivity and specificity of UTI diagnosis by LE-PAD were 87.5% and 92.3%, while the LE-positivities of urine dipstics were 62.5% and 76.9%, respectively. For UTI diagnosis, the LE-PAD demonstrated positive and negative likelihood ratios of 11.38 and 0.14, suggesting that the novel LE-PAD is aAbstract : A novel chemiresistive method for quantitative determination of leukocyte esterase. Abstract : The commercially-available colorimetric urine dipstic for the early detection of urinary tract infection (UTI) has several limitations. The quantitative determination of urinary leukocyte esterase (LE) for predicting UTI remains uncertain. This study presents a paper-based analytical device to detect LE (LE-PAD) as a point-of-care quantitative test for UTI. The LE-PAD is composed of a coating of mixed 3-( N -tosyl-L-alaninyloxy)-5-phenylpyrrole (PE) and 1-diazo-2-naphthol-4-sulfonic acid (DAS) deposited onto a silver conducting film (Ag film). The LE/urine reacts with the PE and DAS, and the resulting products in turn react with the silver coating, causing a change in resistivity. The quantitative calibration curve was established in this study and has been used to analyse urine samples from inpatients with urinary catheters ( n = 21). The results revealed that the level of LE determined by LE-PADs was predictive of UTI diagnosis with an area under the receiver operating characteristic curve of 0.875 (95% confidence interval, 0.704–1.000). Using an appropriate cut-off value, the sensitivity and specificity of UTI diagnosis by LE-PAD were 87.5% and 92.3%, while the LE-positivities of urine dipstics were 62.5% and 76.9%, respectively. For UTI diagnosis, the LE-PAD demonstrated positive and negative likelihood ratios of 11.38 and 0.14, suggesting that the novel LE-PAD is a reliable test. … (more)
- Is Part Of:
- RSC advances. Volume 10:Issue 45(2020)
- Journal:
- RSC advances
- Issue:
- Volume 10:Issue 45(2020)
- Issue Display:
- Volume 10, Issue 45 (2020)
- Year:
- 2020
- Volume:
- 10
- Issue:
- 45
- Issue Sort Value:
- 2020-0010-0045-0000
- Page Start:
- 27042
- Page End:
- 27049
- Publication Date:
- 2020-07-21
- Subjects:
- Chemistry -- Periodicals
540.5 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/RA ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d0ra03306e ↗
- Languages:
- English
- ISSNs:
- 2046-2069
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8036.750300
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13867.xml