The high-accuracy prediction of carbon content in semi-coke by laser-induced breakdown spectroscopy. Issue 5 (16th April 2020)
- Record Type:
- Journal Article
- Title:
- The high-accuracy prediction of carbon content in semi-coke by laser-induced breakdown spectroscopy. Issue 5 (16th April 2020)
- Main Title:
- The high-accuracy prediction of carbon content in semi-coke by laser-induced breakdown spectroscopy
- Authors:
- Xu, Xiangjun
Li, Angze
Wang, Xianshuang
Ding, Chunjie
Qiu, Suling
He, Yage
Lu, Tianqi
He, Feng
Zou, Bingsuo
Liu, Ruibin - Abstract:
- Abstract : LIBS technology is used in the realization process of semi-coke detection. Abstract : Semi-coke, as a kind of special coal resource with a relatively high concentration of carbon and low volatility, plays an important role in the coal chemical industry and in creating clean cities. Laser-induced breakdown spectroscopy (LIBS) has been proved to be an effective way to conduct online analysis of coal products. However, the lower volatility of semi-coke makes it hard to press into a slice to obtain a smooth surface for uniform laser-irradiation. Therefore, it is necessary to find an effective way to realize high-accuracy LIBS detection for semi-coke applications. Herein, two feasible methods of sample preparation are attempted, one easy way involves directly painting semi-coke powder onto tape that is suitable for online fast monitoring, and the other more complicated way is to mix a binder into the semi-coke powder so that uniform and tight coal slices are obtained, to improve the repeatability of the measurements. Moreover, a totally new algorithm, a support vector machine (SVM) combined with partial least square (PLS) regression (SVM-PLS), was utilized to establish an effective prediction model to give a high predictive accuracy. The coefficient of determination ( R 2 ), root mean square error of prediction (RMSEP), and average relative error (ARE) are 0.944, 0.90%, and 0.80%, respectively. In comparison with the results from the traditional PLS model, SVM residualAbstract : LIBS technology is used in the realization process of semi-coke detection. Abstract : Semi-coke, as a kind of special coal resource with a relatively high concentration of carbon and low volatility, plays an important role in the coal chemical industry and in creating clean cities. Laser-induced breakdown spectroscopy (LIBS) has been proved to be an effective way to conduct online analysis of coal products. However, the lower volatility of semi-coke makes it hard to press into a slice to obtain a smooth surface for uniform laser-irradiation. Therefore, it is necessary to find an effective way to realize high-accuracy LIBS detection for semi-coke applications. Herein, two feasible methods of sample preparation are attempted, one easy way involves directly painting semi-coke powder onto tape that is suitable for online fast monitoring, and the other more complicated way is to mix a binder into the semi-coke powder so that uniform and tight coal slices are obtained, to improve the repeatability of the measurements. Moreover, a totally new algorithm, a support vector machine (SVM) combined with partial least square (PLS) regression (SVM-PLS), was utilized to establish an effective prediction model to give a high predictive accuracy. The coefficient of determination ( R 2 ), root mean square error of prediction (RMSEP), and average relative error (ARE) are 0.944, 0.90%, and 0.80%, respectively. In comparison with the results from the traditional PLS model, SVM residual correction greatly improves the quality of the calibration curve and the RMSEP and ARE values are reduced to 0.17%, thus improving the prediction accuracy, which is much better than the basic PLS regression. Meanwhile, the prediction error from the binder mixed semi-coke slice is significantly reduced compared to that of the directly painted samples on tape. The maximum relative errors (MREs) are 2.71% and 5.19%, and the average RSD values of the characteristic peaks are 12.1% and 16.2%, respectively, indicating that the easy way of painting a sample on tape has some prediction uncertainties. Finally, in a three-day random test, the average RMSEP was found to be 1.89% and the average ARE was 1.74%, which also proves that the binder additive can effectively reduce the matrix effect and enhance the stability of the spectrum for semi-coke measurements. The results indicate that appropriate LIBS analysis on semi-coke is a feasible and promising approach for online predictions using this kind of coal sample. … (more)
- Is Part Of:
- Journal of analytical atomic spectrometry. Volume 35:Issue 5(2020)
- Journal:
- Journal of analytical atomic spectrometry
- Issue:
- Volume 35:Issue 5(2020)
- Issue Display:
- Volume 35, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 35
- Issue:
- 5
- Issue Sort Value:
- 2020-0035-0005-0000
- Page Start:
- 984
- Page End:
- 992
- Publication Date:
- 2020-04-16
- Subjects:
- Atomic spectra -- Periodicals
Atomic absorption spectroscopy -- Periodicals
543.0858 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/ja#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c9ja00443b ↗
- Languages:
- English
- ISSNs:
- 0267-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4928.200000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13863.xml