Multicentre clinical evaluation of the safety and performance of a simple transperineal access system for prostate biopsies for suspected prostate cancer: The CAMbridge PROstate Biopsy DevicE (CamPROBE) study. (September 2020)
- Record Type:
- Journal Article
- Title:
- Multicentre clinical evaluation of the safety and performance of a simple transperineal access system for prostate biopsies for suspected prostate cancer: The CAMbridge PROstate Biopsy DevicE (CamPROBE) study. (September 2020)
- Main Title:
- Multicentre clinical evaluation of the safety and performance of a simple transperineal access system for prostate biopsies for suspected prostate cancer: The CAMbridge PROstate Biopsy DevicE (CamPROBE) study
- Authors:
- Gnanapragasam, Vincent J
Leonard, Kelly
Sut, Michal
Ilie, Cristian
Ord, Jonathan
Roux, Jacques
Prieto, Maria Consuelo Hart
Warren, Anne
Tamer, Priya - Abstract:
- Objectives: To report the prospective multicentre clinical evaluation of a first-in-man disposable device, Cambridge Prostate Biopsy Device, to undertake local anaesthetic outpatient transperineal prostate biopsies. Material and methods: Disposable single-use Cambridge Prostate Biopsy devices were manufactured based on a previous prototype. The lead site developed a user training course and disseminated the method to other sites. The Cambridge Prostate Biopsy Device (CamPROBE) was offered as an alternative to transrectal ultrasound guided biopsy to men due for a biopsy as part of their clinical management. Data on safety (infections and device performance), clinical utility, patient reported experience, biopsy quality and cancer detection were collected. Procedure time and local anaesthetic use was recorded in the lead site. The study was funded by a United Kingdom National Institute for Health Research (NIHR) i4i product development award. Results: A total of 40 patients were recruited (median age 69 y) across six sites; five sites were new to the procedure. Overall, 19/40 were first prostate biopsies and 21/40 repeat procedures. Both image-targeted and systematic biopsy cores taken. There were no infections, device deficiencies or safety issues reported. The procedure was well tolerated with excellent patient-reported perception and low pain scores (median of 3, scale 0–10). Histopathology quality was good and the overall cancer diagnosis rate (first diagnostic procedures)Objectives: To report the prospective multicentre clinical evaluation of a first-in-man disposable device, Cambridge Prostate Biopsy Device, to undertake local anaesthetic outpatient transperineal prostate biopsies. Material and methods: Disposable single-use Cambridge Prostate Biopsy devices were manufactured based on a previous prototype. The lead site developed a user training course and disseminated the method to other sites. The Cambridge Prostate Biopsy Device (CamPROBE) was offered as an alternative to transrectal ultrasound guided biopsy to men due for a biopsy as part of their clinical management. Data on safety (infections and device performance), clinical utility, patient reported experience, biopsy quality and cancer detection were collected. Procedure time and local anaesthetic use was recorded in the lead site. The study was funded by a United Kingdom National Institute for Health Research (NIHR) i4i product development award. Results: A total of 40 patients were recruited (median age 69 y) across six sites; five sites were new to the procedure. Overall, 19/40 were first prostate biopsies and 21/40 repeat procedures. Both image-targeted and systematic biopsy cores taken. There were no infections, device deficiencies or safety issues reported. The procedure was well tolerated with excellent patient-reported perception and low pain scores (median of 3, scale 0–10). Histopathology quality was good and the overall cancer diagnosis rate (first diagnostic procedures) was 68% (13/19) and for significant cancers (⩾ histological Grade Group 2), 47% (9/19). In the lead centre (most experienced), median procedure time was 25 minutes, and median local anaesthetic use 11 ml ( n =17). Conclusions: Data from this device evaluation study demonstrate that the United Kingdom-developed Cambridge Prostate Biopsy Device/method for transperineal biopsies is safe, transferable and maintains high diagnostic yields. The procedure is well tolerated by patients, suited to the local anaesthetic outpatient setting and could directly replace transrectal ultrasound guided biopsy. Level of evidence: Level III … (more)
- Is Part Of:
- Journal of clinical urology. Volume 13:Number 5(2020)
- Journal:
- Journal of clinical urology
- Issue:
- Volume 13:Number 5(2020)
- Issue Display:
- Volume 13, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 13
- Issue:
- 5
- Issue Sort Value:
- 2020-0013-0005-0000
- Page Start:
- 364
- Page End:
- 370
- Publication Date:
- 2020-09
- Subjects:
- CamPROBE -- local anaesthetic -- prostate cancer -- transrectal biopsy -- transperineal biopsy -- safety -- infection -- clinical evaluation -- first in man -- NIHR
Genitourinary organs -- Surgery -- Periodicals
Genitourinary organs -- Diseases -- Periodicals
Urology -- Periodicals
616.6005 - Journal URLs:
- http://uro.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗
http://www.uk.sagepub.com/journals/Journal202162 ↗ - DOI:
- 10.1177/2051415820932773 ↗
- Languages:
- English
- ISSNs:
- 2051-4158
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13853.xml