Depth profiling by pulsed glow discharge time-of-flight mass spectrometry with a combined hollow cathode cell. Issue 8 (10th July 2020)
- Record Type:
- Journal Article
- Title:
- Depth profiling by pulsed glow discharge time-of-flight mass spectrometry with a combined hollow cathode cell. Issue 8 (10th July 2020)
- Main Title:
- Depth profiling by pulsed glow discharge time-of-flight mass spectrometry with a combined hollow cathode cell
- Authors:
- Gubal, Anna
Chuchina, Victoria
Lyalkin, Yegor
Mikhailovskii, Vladimir
Yakobson, Viktor
Solovyev, Nikolay
Ganeev, Alexander - Abstract:
- Abstract : A combined hollow cathode microsecond direct current pulsed glow discharge time-of-flight mass spectrometry system has proved its efficiency for quantification; however, it has not been properly tested for the purpose of depth analysis. Abstract : A combined hollow cathode microsecond direct current pulsed glow discharge time-of-flight mass spectrometry (CHC μs-DC-PGD TOFMS) system has proved its efficiency for quantification; however, it has not been properly tested for the purpose of depth analysis until now, to the best of the authors' knowledge. The aim of the current study was to investigate the capabilities of this glow discharge source type for depth profiling. Special attention was paid to the alteration of depth resolution during the sputtering and the effect of discharge parameters on the crater shape in different types of solid samples. Both dielectric and conductive samples were tested, including: a Ni film on silicon, a Si film on borosilicate glass, and IR-reflective dielectric multilayer (mirror) coatings. Crater shapes were investigated after combined hollow cathode cell sputtering to ensure reliable profiling. For dielectric materials, including multilayer coatings, the deposition of a thin conducting layer (Ag or Ta) on the sample surface was demonstrated to result in reliable sputtering with adequate depth resolution of the profiling. This preliminary sample coating provided both the formation of required surface conductivity and reduction ofAbstract : A combined hollow cathode microsecond direct current pulsed glow discharge time-of-flight mass spectrometry system has proved its efficiency for quantification; however, it has not been properly tested for the purpose of depth analysis. Abstract : A combined hollow cathode microsecond direct current pulsed glow discharge time-of-flight mass spectrometry (CHC μs-DC-PGD TOFMS) system has proved its efficiency for quantification; however, it has not been properly tested for the purpose of depth analysis until now, to the best of the authors' knowledge. The aim of the current study was to investigate the capabilities of this glow discharge source type for depth profiling. Special attention was paid to the alteration of depth resolution during the sputtering and the effect of discharge parameters on the crater shape in different types of solid samples. Both dielectric and conductive samples were tested, including: a Ni film on silicon, a Si film on borosilicate glass, and IR-reflective dielectric multilayer (mirror) coatings. Crater shapes were investigated after combined hollow cathode cell sputtering to ensure reliable profiling. For dielectric materials, including multilayer coatings, the deposition of a thin conducting layer (Ag or Ta) on the sample surface was demonstrated to result in reliable sputtering with adequate depth resolution of the profiling. This preliminary sample coating provided both the formation of required surface conductivity and reduction of the negative effect of atmospheric gases and water surface contamination at the beginning of sample sputtering. A silicon-coated borosilicate glass specimen was tested for potential quantitative profiling, showing promising results. The CHC μs-DC-PGD TOFMS system used was capable of analyzing the layers of varied thickness in the range from tens of nanometers to several micrometers. The depth resolution was 5 nm and 25 nm for conducting and dielectric layers, respectively. … (more)
- Is Part Of:
- Journal of analytical atomic spectrometry. Volume 35:Issue 8(2020)
- Journal:
- Journal of analytical atomic spectrometry
- Issue:
- Volume 35:Issue 8(2020)
- Issue Display:
- Volume 35, Issue 8 (2020)
- Year:
- 2020
- Volume:
- 35
- Issue:
- 8
- Issue Sort Value:
- 2020-0035-0008-0000
- Page Start:
- 1587
- Page End:
- 1596
- Publication Date:
- 2020-07-10
- Subjects:
- Atomic spectra -- Periodicals
Atomic absorption spectroscopy -- Periodicals
543.0858 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/ja#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d0ja00088d ↗
- Languages:
- English
- ISSNs:
- 0267-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4928.200000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13830.xml