A poly(N, N-dimethylaminoethyl methacrylate-co-ethylene glycol dimethacrylate) monolith for direct solid-phase extraction of benzodiazepines from undiluted human urine. Issue 31 (28th July 2020)
- Record Type:
- Journal Article
- Title:
- A poly(N, N-dimethylaminoethyl methacrylate-co-ethylene glycol dimethacrylate) monolith for direct solid-phase extraction of benzodiazepines from undiluted human urine. Issue 31 (28th July 2020)
- Main Title:
- A poly(N, N-dimethylaminoethyl methacrylate-co-ethylene glycol dimethacrylate) monolith for direct solid-phase extraction of benzodiazepines from undiluted human urine
- Authors:
- Zhao, Tengwen
Du, Li
Zhang, Ziyang
Li, Na
Wang, Manman
Ren, Qi - Abstract:
- Abstract : A poly( N, N -dimethylaminoethyl methacrylate- co -ethylene glycol dimethacrylate) monolith was successfully synthesized and applied for direct solid-phase extraction of benzodiazepines from undiluted urine samples. Abstract : A novel polymeric monolith using N, N -dimethylaminoethyl methacrylate as the monomer and ethylene glycol dimethacrylate as the crosslinker was successfully synthesized in a syringe and applied for direct solid-phase extraction of four benzodiazepines (bromazepam, triazolam, midazolam and diazepam) from undiluted urine samples prior to high performance liquid chromatography. The monolith was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy and nitrogen adsorption–desorption experiments. Moreover, extraction parameters, including loading, washing and eluting conditions were optimized. Under the optimized conditions, the proposed method obtained linear ranges of 2.0–500 ng mL −1 with correlation coefficients ( r ) higher than 0.9997. The limits of detection (S/N = 3) and limits of quantification (S/N = 10) were 0.4–0.6 ng mL −1 and 1.4–2.0 ng mL −1, respectively. The recoveries at three spiked levels ranged from 83.7% to 103% with the intra- and inter-day precisions from 0.6–7.6% to 2.7–9.8%. The present monolith allowed direct loading of crude urine samples without any filtration or dilution step. Besides, the sorbent offered an enhancement factor of 16.7–20.6 and was stable enough for ten replicateAbstract : A poly( N, N -dimethylaminoethyl methacrylate- co -ethylene glycol dimethacrylate) monolith was successfully synthesized and applied for direct solid-phase extraction of benzodiazepines from undiluted urine samples. Abstract : A novel polymeric monolith using N, N -dimethylaminoethyl methacrylate as the monomer and ethylene glycol dimethacrylate as the crosslinker was successfully synthesized in a syringe and applied for direct solid-phase extraction of four benzodiazepines (bromazepam, triazolam, midazolam and diazepam) from undiluted urine samples prior to high performance liquid chromatography. The monolith was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy and nitrogen adsorption–desorption experiments. Moreover, extraction parameters, including loading, washing and eluting conditions were optimized. Under the optimized conditions, the proposed method obtained linear ranges of 2.0–500 ng mL −1 with correlation coefficients ( r ) higher than 0.9997. The limits of detection (S/N = 3) and limits of quantification (S/N = 10) were 0.4–0.6 ng mL −1 and 1.4–2.0 ng mL −1, respectively. The recoveries at three spiked levels ranged from 83.7% to 103% with the intra- and inter-day precisions from 0.6–7.6% to 2.7–9.8%. The present monolith allowed direct loading of crude urine samples without any filtration or dilution step. Besides, the sorbent offered an enhancement factor of 16.7–20.6 and was stable enough for ten replicate cycles of extraction/desorption of urine samples. The developed method presented an alternative strategy for the accurate and convenient determination of benzodiazepines in urine samples. … (more)
- Is Part Of:
- Analytical methods. Volume 12:Issue 31(2020)
- Journal:
- Analytical methods
- Issue:
- Volume 12:Issue 31(2020)
- Issue Display:
- Volume 12, Issue 31 (2020)
- Year:
- 2020
- Volume:
- 12
- Issue:
- 31
- Issue Sort Value:
- 2020-0012-0031-0000
- Page Start:
- 3924
- Page End:
- 3932
- Publication Date:
- 2020-07-28
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d0ay01025a ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13828.xml