X-ray tube with artificial neural network model as a promising alternative for radioisotope source in radiation based two phase flowmeters. (October 2020)
- Record Type:
- Journal Article
- Title:
- X-ray tube with artificial neural network model as a promising alternative for radioisotope source in radiation based two phase flowmeters. (October 2020)
- Main Title:
- X-ray tube with artificial neural network model as a promising alternative for radioisotope source in radiation based two phase flowmeters
- Authors:
- Roshani, Mohammadmehdi
Muhammad Ali, Peshawa Jammal
Roshani, Gholam Hossein
Nazemi, Behrooz
Corniani, Enrico
Phan, Nhut-Huan
Tran, Hoai-Nam
Nazemi, Ehsan - Abstract:
- Abstract: In this paper, X-ray tube is introduced as a potential alternative for radioisotope sources used in radiation based liquid-gas two-phase flowmeters. X-ray tubes have lots of advantages over the radioisotope sources such as having an adjustable emitting photon's energy, being safer from point of view of radiation health physics during the transportation of the source, having ability to generate a high flux photon beam, and etc. The proposed radiation based system in this study composes an X-ray tube with a tube voltage of 150 kV and a 2.5 mm aluminum filter as the radiation source and one sodium iodide crystal as the photon detector. A pipe was positioned between the X-ray tube and the detector. Two main flow regimes of annular and stratified with different void fractions were modelled inside the pipe. Artificial neural network model of multi-layer perceptron (MLP) was also used in this study for analyzing the obtained data. The output spectrum of sodium iodide detector with 150 samples was applied as the input of multi-layer perceptron network and void fraction was considered as its output. The root mean squared error of proposed measuring system was 4.13 which shows the X-ray tube can be implemented as a promising alternative for radioisotope in radiation based two phase flow meters. Highlights: X-ray tube with ANN was introduced as a potential alternative for radioisotope sources. The proposed system composes an X-ray tube and one NaI detector. Two flow regimesAbstract: In this paper, X-ray tube is introduced as a potential alternative for radioisotope sources used in radiation based liquid-gas two-phase flowmeters. X-ray tubes have lots of advantages over the radioisotope sources such as having an adjustable emitting photon's energy, being safer from point of view of radiation health physics during the transportation of the source, having ability to generate a high flux photon beam, and etc. The proposed radiation based system in this study composes an X-ray tube with a tube voltage of 150 kV and a 2.5 mm aluminum filter as the radiation source and one sodium iodide crystal as the photon detector. A pipe was positioned between the X-ray tube and the detector. Two main flow regimes of annular and stratified with different void fractions were modelled inside the pipe. Artificial neural network model of multi-layer perceptron (MLP) was also used in this study for analyzing the obtained data. The output spectrum of sodium iodide detector with 150 samples was applied as the input of multi-layer perceptron network and void fraction was considered as its output. The root mean squared error of proposed measuring system was 4.13 which shows the X-ray tube can be implemented as a promising alternative for radioisotope in radiation based two phase flow meters. Highlights: X-ray tube with ANN was introduced as a potential alternative for radioisotope sources. The proposed system composes an X-ray tube and one NaI detector. Two flow regimes of annular and stratified with different void fractions were modelled. ANN model of multi-layer perceptron (MLP) was used. The detector's output with 150 samples was applied as the input of MLP-LM network. … (more)
- Is Part Of:
- Applied radiation and isotopes. Volume 164(2020:Oct.)
- Journal:
- Applied radiation and isotopes
- Issue:
- Volume 164(2020:Oct.)
- Issue Display:
- Volume 164 (2020)
- Year:
- 2020
- Volume:
- 164
- Issue Sort Value:
- 2020-0164-0000-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-10
- Subjects:
- Two phase flow -- X-ray tube -- Void fraction -- Neural network
Radiology -- Periodicals
Radiation -- Industrial applications -- Periodicals
Nuclear chemistry -- Periodicals
Internet resource
Periodical
660.298 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09698043 ↗
http://catalog.hathitrust.org/api/volumes/oclc/27456684.html ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apradiso.2020.109255 ↗
- Languages:
- English
- ISSNs:
- 0969-8043
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1576.565000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13810.xml