Dual directions to address the problem of aseptic loosening via electrospun PLGA @ aspirin nanofiber coatings on titanium. (October 2020)
- Record Type:
- Journal Article
- Title:
- Dual directions to address the problem of aseptic loosening via electrospun PLGA @ aspirin nanofiber coatings on titanium. (October 2020)
- Main Title:
- Dual directions to address the problem of aseptic loosening via electrospun PLGA @ aspirin nanofiber coatings on titanium
- Authors:
- Wei, Yaojie
Liu, Zhongqun
Zhu, Xu
Jiang, Le
Shi, Weidong
Wang, Yingjin
Xu, Nan
Gang, Fangli
Wang, Xiumei
Zhao, Lingyun
Lin, Jun
Sun, Xiaodan - Abstract:
- Abstract: Peri-implant aseptic inflammation and osteolysis can cause aseptic loosening, leading to the failure of implants. Therefore, aseptic loosening of orthopedic implants remains an imminent problem for the development of durable and effective implants. In this work, a common anti-inflammatory drug (aspirin, ASA) was loaded in poly(lactic-co-glycolic acid) (PLGA) to construct nanofiber coatings on titanium (Ti) via electrospinning. The adhesion of the nanofiber coatings to Ti was ensured by polydopamine (PDA) modification. A stable and sustainable release of aspirin from the nanofiber coatings could last up to 60 days. Such electrospun PLGA@ASA nanofiber coatings could promote proliferation and osteogenic differentiation of bone mesenchymal stem cells (BMSCs) as well as inhibit M1 polarization and RANKL-induced osteoclast differentiation of macrophages in vitro . These results indicated that this facile formulation of the PLGA@ASA nanofiber coatings for long-term drug release could be expected to address the problem of aseptic loosening effectively in dual directions of both anti-inflammation and improving osseointegration simultaneously. Notably, the in vivo experiments demonstrated that PLGA@ASA nanofiber coatings did promote osseointegration ability of Ti implants significantly, even in challenging condition with wear particles, and also effectively inhibited Ti particle induced osteolysis around the implants. This work indicates a promising way for the developmentAbstract: Peri-implant aseptic inflammation and osteolysis can cause aseptic loosening, leading to the failure of implants. Therefore, aseptic loosening of orthopedic implants remains an imminent problem for the development of durable and effective implants. In this work, a common anti-inflammatory drug (aspirin, ASA) was loaded in poly(lactic-co-glycolic acid) (PLGA) to construct nanofiber coatings on titanium (Ti) via electrospinning. The adhesion of the nanofiber coatings to Ti was ensured by polydopamine (PDA) modification. A stable and sustainable release of aspirin from the nanofiber coatings could last up to 60 days. Such electrospun PLGA@ASA nanofiber coatings could promote proliferation and osteogenic differentiation of bone mesenchymal stem cells (BMSCs) as well as inhibit M1 polarization and RANKL-induced osteoclast differentiation of macrophages in vitro . These results indicated that this facile formulation of the PLGA@ASA nanofiber coatings for long-term drug release could be expected to address the problem of aseptic loosening effectively in dual directions of both anti-inflammation and improving osseointegration simultaneously. Notably, the in vivo experiments demonstrated that PLGA@ASA nanofiber coatings did promote osseointegration ability of Ti implants significantly, even in challenging condition with wear particles, and also effectively inhibited Ti particle induced osteolysis around the implants. This work indicates a promising way for the development of durable and effective implants by using PLGA@ASA-PDA-Ti to address the problem of aseptic loosening in dual directions. … (more)
- Is Part Of:
- Biomaterials. Volume 257(2020)
- Journal:
- Biomaterials
- Issue:
- Volume 257(2020)
- Issue Display:
- Volume 257, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 257
- Issue:
- 2020
- Issue Sort Value:
- 2020-0257-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-10
- Subjects:
- Electrospun nanofiber coating -- Aseptic loosening -- Aspirin -- Anti-inflammation -- Osseointegration
Biomedical materials -- Periodicals
Biocompatible Materials -- Periodicals
Biomatériaux -- Périodiques
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01429612 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01429612 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01429612 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.biomaterials.2020.120237 ↗
- Languages:
- English
- ISSNs:
- 0142-9612
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.715000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13815.xml