Is the Vectra 3D Imaging System a Reliable Tool for Predicting Breast Mass?. (July 2020)
- Record Type:
- Journal Article
- Title:
- Is the Vectra 3D Imaging System a Reliable Tool for Predicting Breast Mass?. (July 2020)
- Main Title:
- Is the Vectra 3D Imaging System a Reliable Tool for Predicting Breast Mass?
- Authors:
- Wood, Kasey Leigh
Zoghbi, Yasmina
Margulies, Ilana G.
Ashikari, Andrew Y.
Jacobs, Jordan
Salzberg, Charles Andrew - Abstract:
- Abstract : Background: In selecting breast implants for breast reconstruction, current preoperative planning largely relies on 2-dimensional measurements, which are often limited in suboptimal accuracy and objectivity. Although the introduction of 3-dimensional imaging modalities has further improved preoperative planning, they require in-depth analysis of accuracy if they are to be considered as a standardized part of preoperative planning. Thus, the present study analyzes the reliability of the Vectra 3D Imaging System in predicting breast mass and explores potential confounding variables that may limit its accuracy. Methods: A retrospective review of 202 breasts that received direct-to-implant reconstruction by a single surgeon between February 2015 and February 2019 was conducted. Variables recorded included Vectra predicted mass (VPM; in grams), mastectomy mass (MM; in grams), ptosis grade, and body mass index (BMI). Body mass index was classified as follows: underweight (BMI < 20 kg/m 2 ), normal (20 kg/m 2 ⩽ BMI < 25 kg/m 2 ), overweight (25 kg/m 2 ⩽ BMI < 30 kg/m 2 ), and obese (BMI ≥ 30 kg/m 2 ). Cup size was approximated as follows: A and smaller (MM ⩽250 g), B (250 g < MM ⩽ 450 g), C (450 g < MM ⩽ 600 g), and D and larger (MM ≥ 600 g). Correlation between MM and VPM was evaluated using 2-tailed Pearson correlation coefficients ( r ), and associated formula was derived from a linear model. Equality of variances was assessed with the Bartlett test. CorrelationAbstract : Background: In selecting breast implants for breast reconstruction, current preoperative planning largely relies on 2-dimensional measurements, which are often limited in suboptimal accuracy and objectivity. Although the introduction of 3-dimensional imaging modalities has further improved preoperative planning, they require in-depth analysis of accuracy if they are to be considered as a standardized part of preoperative planning. Thus, the present study analyzes the reliability of the Vectra 3D Imaging System in predicting breast mass and explores potential confounding variables that may limit its accuracy. Methods: A retrospective review of 202 breasts that received direct-to-implant reconstruction by a single surgeon between February 2015 and February 2019 was conducted. Variables recorded included Vectra predicted mass (VPM; in grams), mastectomy mass (MM; in grams), ptosis grade, and body mass index (BMI). Body mass index was classified as follows: underweight (BMI < 20 kg/m 2 ), normal (20 kg/m 2 ⩽ BMI < 25 kg/m 2 ), overweight (25 kg/m 2 ⩽ BMI < 30 kg/m 2 ), and obese (BMI ≥ 30 kg/m 2 ). Cup size was approximated as follows: A and smaller (MM ⩽250 g), B (250 g < MM ⩽ 450 g), C (450 g < MM ⩽ 600 g), and D and larger (MM ≥ 600 g). Correlation between MM and VPM was evaluated using 2-tailed Pearson correlation coefficients ( r ), and associated formula was derived from a linear model. Equality of variances was assessed with the Bartlett test. Correlation coefficients calculated for ptosis and BMI categories were then compared with the overall correlation coefficient. Significance was set at α = 0.05, and analyses were conducted in R 3.6.0, version 1.70. Results: There was a strong correlation between MM and VPM ( R = 0.90, P < 0.0001). The following equation was derived to predict MM: [MM] = 0.8 × [VPM] + 32 (adjusted r 2 = 0.81). The Bartlett test indicated that VPM varies significantly across cup sizes ( P < 0.0001). Comparison of correlation coefficients for ptosis and BMI categories revealed a significantly reduced correlation coefficient for pseudoptosis (0.90 vs 0.75, P = 0.0425). Conclusions: The present study suggests that the reliability of Vectra in predicting breast mass varies across cup sizes and that there exists a significantly decreased association between VPM and MM among pseudoptotic breasts. These are important considerations when using this technology in surgical planning. … (more)
- Is Part Of:
- Annals of plastic surgery. Volume 85(2020)Supplement 1 1S
- Journal:
- Annals of plastic surgery
- Issue:
- Volume 85(2020)Supplement 1 1S
- Issue Display:
- Volume 85, Issue 1, Part 1 (2020)
- Year:
- 2020
- Volume:
- 85
- Issue:
- 1
- Part:
- 1
- Issue Sort Value:
- 2020-0085-0001-0001
- Page Start:
- Page End:
- Publication Date:
- 2020-07
- Subjects:
- breast -- mammaplasty -- preoperative care -- correlation of data -- observational study
Surgery, Plastic -- Periodicals
617.95205 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00000637-000000000-00000 ↗
http://www.annalsplasticsurgery.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/SAP.0000000000002333 ↗
- Languages:
- English
- ISSNs:
- 0148-7043
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1043.525000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13807.xml