Atrial premature depolarisations five days post electrical cardioversion are related to atrial fibrillation recurrence risk in horses. (24th October 2019)
- Record Type:
- Journal Article
- Title:
- Atrial premature depolarisations five days post electrical cardioversion are related to atrial fibrillation recurrence risk in horses. (24th October 2019)
- Main Title:
- Atrial premature depolarisations five days post electrical cardioversion are related to atrial fibrillation recurrence risk in horses
- Authors:
- Vernemmen, I.
De Clercq, D.
Decloedt, A.
Vera, L.
Van Steenkiste, G.
van Loon, G. - Abstract:
- Summary: Background: The number of atrial premature depolarisations (APDs) is a known risk factor for atrial fibrillation (AF) recurrence in humans. Objectives: To evaluate if the number of APDs over a 24‐h period 5 days post cardioversion predicts AF recurrence within 1 year in horses, taking the multifactorial nature of AF into account. Study design: Retrospective case series. Methods: Eighty horses met these inclusion criteria: first AF episode, no AF recurrence within 5 days post cardioversion, cardioversion by transvenous electrical cardioversion (TVEC), 24‐h ECG recording and echocardiographic examination 5 days post cardioversion, no antiarrhythmic treatment during the ECG recording and follow‐up of minimum 1 year. To compare the APD burden between the recurrence and non‐recurrence group a Mann–Whitney U test was used. A multivariable survival model was built to identify additional risk factors for AF recurrence. Results: The patient population mainly consisted of Warmbloods (93%). Twenty‐six horses (33%) experienced AF recurrence within 1 year. The number of APDs (median [range]) was significantly higher (P = 0.01) in the recurrence group (15 [1–152]) compared with the non‐recurrence group (7 [0–304]). In the multivariable survival model, APDs ≥25/24 h (hazard ratio [HR] 2.9, 95% confidence interval [CI] 1.2–6.8, P = 0.02), mitral regurgitation (HR 8.6, 95% CI 2.6–28.9, P<0.001), left atrial active fractional area change ≤9.6% (HR 2.6, 95% CI 1.0–6.5, P = 0.04) andSummary: Background: The number of atrial premature depolarisations (APDs) is a known risk factor for atrial fibrillation (AF) recurrence in humans. Objectives: To evaluate if the number of APDs over a 24‐h period 5 days post cardioversion predicts AF recurrence within 1 year in horses, taking the multifactorial nature of AF into account. Study design: Retrospective case series. Methods: Eighty horses met these inclusion criteria: first AF episode, no AF recurrence within 5 days post cardioversion, cardioversion by transvenous electrical cardioversion (TVEC), 24‐h ECG recording and echocardiographic examination 5 days post cardioversion, no antiarrhythmic treatment during the ECG recording and follow‐up of minimum 1 year. To compare the APD burden between the recurrence and non‐recurrence group a Mann–Whitney U test was used. A multivariable survival model was built to identify additional risk factors for AF recurrence. Results: The patient population mainly consisted of Warmbloods (93%). Twenty‐six horses (33%) experienced AF recurrence within 1 year. The number of APDs (median [range]) was significantly higher (P = 0.01) in the recurrence group (15 [1–152]) compared with the non‐recurrence group (7 [0–304]). In the multivariable survival model, APDs ≥25/24 h (hazard ratio [HR] 2.9, 95% confidence interval [CI] 1.2–6.8, P = 0.02), mitral regurgitation (HR 8.6, 95% CI 2.6–28.9, P<0.001), left atrial active fractional area change ≤9.6% (HR 2.6, 95% CI 1.0–6.5, P = 0.04) and lower body weight (HR 0.99, 95% CI 0.98–0.99, P = 0.001) were significantly associated with AF recurrence. Main limitations: This study did not evaluate early AF recurrence within 5 days. The results cannot necessarily be extrapolated to other treatment methods, as only horses converted by TVEC were included. Conclusions: The APD burden 5 days post cardioversion could be a useful predictive value for AF recurrence within 1 year in horses. However, other factors such as mitral regurgitation and atrial contractile function must also be taken into account. … (more)
- Is Part Of:
- Equine veterinary journal. Volume 52:Number 3(2020)
- Journal:
- Equine veterinary journal
- Issue:
- Volume 52:Number 3(2020)
- Issue Display:
- Volume 52, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 52
- Issue:
- 3
- Issue Sort Value:
- 2020-0052-0003-0000
- Page Start:
- 374
- Page End:
- 378
- Publication Date:
- 2019-10-24
- Subjects:
- horse -- transvenous electrical cardioversion -- atrial ectopy -- arrhythmias -- electrocardiogram
Horses -- Diseases -- Periodicals
636.108905 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1001/(ISSN)2042-3306 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.ingentaconnect.com/content/evj/evj ↗ - DOI:
- 10.1111/evj.13186 ↗
- Languages:
- English
- ISSNs:
- 0425-1644
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3794.520000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13798.xml