AAPM Task Group 329: Reference dose specification for dose calculations: Dose‐to‐water or dose‐to‐muscle?. Issue 3 (28th January 2020)
- Record Type:
- Journal Article
- Title:
- AAPM Task Group 329: Reference dose specification for dose calculations: Dose‐to‐water or dose‐to‐muscle?. Issue 3 (28th January 2020)
- Main Title:
- AAPM Task Group 329: Reference dose specification for dose calculations: Dose‐to‐water or dose‐to‐muscle?
- Authors:
- Kry, Stephen F.
Feygelman, Vladimir
Balter, Peter
Knöös, Tommy
Charlie Ma, C.‐M.
Snyder, Michael
Tonner, Brian
Vassiliev, Oleg N. - Abstract:
- Abstract : Linac calibration is done in water, but patients are comprised primarily of soft tissue. Conceptually, and specified in NRG/RTOG trials, dose should be reported as dose‐to‐muscle to describe the dose to the patient. Historically, the dose‐to‐water of the linac calibration was often converted to dose‐to‐muscle for patient calculations through manual application of a 0.99 dose‐to‐water to dose‐to‐muscle correction factor, applied during the linac clinical reference calibration. However, many current treatment planning system (TPS) dose calculation algorithms approximately provide dose‐to‐muscle (tissue), making application of a manual scaling unnecessary. There is little guidance on when application of a scaling factor is appropriate, resulting in highly inconsistent application of this scaling by the community. In this report we provide guidance on the steps necessary to go from the linac absorbed dose‐to‐water calibration to dose‐to‐muscle in patient, for various commercial TPS algorithms. If the TPS does not account for the difference between dose‐to‐water and dose‐to‐muscle, then TPS reference dose scaling is warranted. We have tabulated the major vendors' TPS in terms of whether they approximate dose‐to‐muscle or calculate dose‐to‐water and recommend the correction factor required to report dose‐to‐muscle directly from the TPS algorithm. Physicists should use this report to determine the applicable correction required for specifying the reference dose in theirAbstract : Linac calibration is done in water, but patients are comprised primarily of soft tissue. Conceptually, and specified in NRG/RTOG trials, dose should be reported as dose‐to‐muscle to describe the dose to the patient. Historically, the dose‐to‐water of the linac calibration was often converted to dose‐to‐muscle for patient calculations through manual application of a 0.99 dose‐to‐water to dose‐to‐muscle correction factor, applied during the linac clinical reference calibration. However, many current treatment planning system (TPS) dose calculation algorithms approximately provide dose‐to‐muscle (tissue), making application of a manual scaling unnecessary. There is little guidance on when application of a scaling factor is appropriate, resulting in highly inconsistent application of this scaling by the community. In this report we provide guidance on the steps necessary to go from the linac absorbed dose‐to‐water calibration to dose‐to‐muscle in patient, for various commercial TPS algorithms. If the TPS does not account for the difference between dose‐to‐water and dose‐to‐muscle, then TPS reference dose scaling is warranted. We have tabulated the major vendors' TPS in terms of whether they approximate dose‐to‐muscle or calculate dose‐to‐water and recommend the correction factor required to report dose‐to‐muscle directly from the TPS algorithm. Physicists should use this report to determine the applicable correction required for specifying the reference dose in their TPS to achieve this goal and should remain attentive to possible changes to their dose calculation algorithm in the future. … (more)
- Is Part Of:
- Medical physics. Volume 47:Issue 3(2020)
- Journal:
- Medical physics
- Issue:
- Volume 47:Issue 3(2020)
- Issue Display:
- Volume 47, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 3
- Issue Sort Value:
- 2020-0047-0003-0000
- Page Start:
- e52
- Page End:
- e64
- Publication Date:
- 2020-01-28
- Subjects:
- calibration -- medium -- muscle -- reference -- water
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13995 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13794.xml