Comparison of 1-Year Effectiveness of Trabecular Microbypass Stent implantation (iStent) in Conjunction With Phacoemulsification Among Mild, Moderate, and Severe Primary Open-angle Glaucoma Patients. Issue 7 (July 2020)
- Record Type:
- Journal Article
- Title:
- Comparison of 1-Year Effectiveness of Trabecular Microbypass Stent implantation (iStent) in Conjunction With Phacoemulsification Among Mild, Moderate, and Severe Primary Open-angle Glaucoma Patients. Issue 7 (July 2020)
- Main Title:
- Comparison of 1-Year Effectiveness of Trabecular Microbypass Stent implantation (iStent) in Conjunction With Phacoemulsification Among Mild, Moderate, and Severe Primary Open-angle Glaucoma Patients
- Authors:
- Chansangpetch, Sunee
Ittarat, Mantapond
Yang, Shuo
Fisher, Ann C.
Singh, Kuldev
Lin, Shan C.
Chang, Robert T. - Abstract:
- Abstract : Precis: The study compared 1-year effectiveness of single trabecular microbypass stent (iStent) implantation with phacoemulsification among glaucoma severities in primary open-angle glaucoma. The study found that mild glaucoma had greater success rate and lower number of medications compared with moderate and severe glaucoma. Purpose: To evaluate the effectiveness of iStent implantation in combination with cataract surgery in moderate to severe glaucoma compared with mild glaucoma. Methods: Medical charts of primary open-angle glaucoma subjects undergoing 1 iStent implantation were retrospectively reviewed. Glaucoma was classified on the basis of mean deviation (MD) of the preoperative standard automated perimetry into mild (MD>−6 dB), moderate (MD −6 to −12 dB), and severe (MD<−12 dB). Mixed effect regression models were performed to determine the effect of iStent at 1 year. The outcomes included as follows: (1) intraocular pressure (IOP) and the number of medications, (2) eyes with IOP ⩽ severity-based target (18 mm Hg for mild, 15 mm Hg for moderate, 12 mm Hg for severe) (2A) without medication, and (2B) with medication reduction. Results: In total, 104 eyes from 89 subjects were analyzed. Cataract combined with iStent surgery significantly lowered the number of medications in all groups and significantly decreased IOP in moderate and severe glaucoma ( P <0.05). There was significantly higher number of medications in moderate (β: 0.58, P =0.002) and severe (β:Abstract : Precis: The study compared 1-year effectiveness of single trabecular microbypass stent (iStent) implantation with phacoemulsification among glaucoma severities in primary open-angle glaucoma. The study found that mild glaucoma had greater success rate and lower number of medications compared with moderate and severe glaucoma. Purpose: To evaluate the effectiveness of iStent implantation in combination with cataract surgery in moderate to severe glaucoma compared with mild glaucoma. Methods: Medical charts of primary open-angle glaucoma subjects undergoing 1 iStent implantation were retrospectively reviewed. Glaucoma was classified on the basis of mean deviation (MD) of the preoperative standard automated perimetry into mild (MD>−6 dB), moderate (MD −6 to −12 dB), and severe (MD<−12 dB). Mixed effect regression models were performed to determine the effect of iStent at 1 year. The outcomes included as follows: (1) intraocular pressure (IOP) and the number of medications, (2) eyes with IOP ⩽ severity-based target (18 mm Hg for mild, 15 mm Hg for moderate, 12 mm Hg for severe) (2A) without medication, and (2B) with medication reduction. Results: In total, 104 eyes from 89 subjects were analyzed. Cataract combined with iStent surgery significantly lowered the number of medications in all groups and significantly decreased IOP in moderate and severe glaucoma ( P <0.05). There was significantly higher number of medications in moderate (β: 0.58, P =0.002) and severe (β: 1.20, P <0.001) compared with mild glaucoma. Eyes with moderate glaucoma had significantly lower rate of success (criterion 2A) compared with mild glaucoma [odds ratio (OR): 0.008, P =0.047]. Eyes with moderate and severe glaucoma had significantly lower rates of success (criterion 2B) (moderate vs. mild OR: 0.002, P =0.028; severe vs. mild OR: 0.026, P =0.026). Conclusions: Combined phacoemulsification with iStent seems to have a better IOP-lowering and medication-lowering effect in mild glaucoma cases versus those with moderate and severe glaucoma. This difference was found in real-world data over one-year follow-up period. Long-term studies with defined IOP goals and medication removal protocols are warranted. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Journal of glaucoma. Volume 29:Issue 7(2020)
- Journal:
- Journal of glaucoma
- Issue:
- Volume 29:Issue 7(2020)
- Issue Display:
- Volume 29, Issue 7 (2020)
- Year:
- 2020
- Volume:
- 29
- Issue:
- 7
- Issue Sort Value:
- 2020-0029-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-07
- Subjects:
- trabecular microbypass stent -- primary open-angle glaucoma -- iStent -- glaucoma severities
Glaucoma -- Periodicals
617.741005 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00061198-000000000-00000 ↗
http://www.glaucomajournal.com ↗
http://journals.lww.com/glaucomajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IJG.0000000000001542 ↗
- Languages:
- English
- ISSNs:
- 1057-0829
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4996.230000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13771.xml