High-intensity Focused Ultrasound Treatment in Moderate Glaucoma Patients: Results of a 2-Year Prospective Clinical Trial. Issue 7 (July 2020)
- Record Type:
- Journal Article
- Title:
- High-intensity Focused Ultrasound Treatment in Moderate Glaucoma Patients: Results of a 2-Year Prospective Clinical Trial. Issue 7 (July 2020)
- Main Title:
- High-intensity Focused Ultrasound Treatment in Moderate Glaucoma Patients
- Authors:
- Leshno, Ari
Rubinstein, Yair
Singer, Reut
Sher, Ifat
Rotenstreich, Ygal
Melamed, Shlomo
Skaat, Alon - Abstract:
- Abstract : Precis: Ultrasound Cyclo Plasty (UCP) treatment using high-intensity focused ultrasound (HIFU) is an effective and safe therapy to reduce intraocular pressure (IOP) in moderate glaucoma patients as was measured during a 2-year follow-up period. Purpose: The purpose of this study was to evaluate the long-term safety and efficacy of the UCP procedure using HIFU in moderate glaucoma patients. Patients and Methods: A prospective interventional noncomparative study was carried out. Fifteen patients (15 eyes) with moderate open-angle glaucoma were enrolled. All eyes were treated with UCP-HIFU. A thorough ophthalmic examination and IOP measurements were performed before the UCP-HIFU procedure and at 1 day, 1 week, 4 weeks, 3 months, 6 months, 1 year, and 2 years after the procedure. The primary outcome was defined as a surgical success (IOP reduction of 20% or ≥5 mm Hg) at the last follow-up visit. The secondary outcomes were the mean IOP at each follow-up visit, number of medications used, complications profile, and reinterventions. Results: The mean preoperative IOP at baseline was 26.8±5.0 mm Hg. All patients had a positive response and a lower IOP after treatment, with a relatively stable 31% reduction in IOP during the follow-up period. A significant reduction in IOP was observed at all postprocedure examination points ( P <0.01), with a mean 17.6±4.4 mm Hg at 2 years after the procedure ( P =0.005). Surgical success was achieved in 87% of the patients at their lastAbstract : Precis: Ultrasound Cyclo Plasty (UCP) treatment using high-intensity focused ultrasound (HIFU) is an effective and safe therapy to reduce intraocular pressure (IOP) in moderate glaucoma patients as was measured during a 2-year follow-up period. Purpose: The purpose of this study was to evaluate the long-term safety and efficacy of the UCP procedure using HIFU in moderate glaucoma patients. Patients and Methods: A prospective interventional noncomparative study was carried out. Fifteen patients (15 eyes) with moderate open-angle glaucoma were enrolled. All eyes were treated with UCP-HIFU. A thorough ophthalmic examination and IOP measurements were performed before the UCP-HIFU procedure and at 1 day, 1 week, 4 weeks, 3 months, 6 months, 1 year, and 2 years after the procedure. The primary outcome was defined as a surgical success (IOP reduction of 20% or ≥5 mm Hg) at the last follow-up visit. The secondary outcomes were the mean IOP at each follow-up visit, number of medications used, complications profile, and reinterventions. Results: The mean preoperative IOP at baseline was 26.8±5.0 mm Hg. All patients had a positive response and a lower IOP after treatment, with a relatively stable 31% reduction in IOP during the follow-up period. A significant reduction in IOP was observed at all postprocedure examination points ( P <0.01), with a mean 17.6±4.4 mm Hg at 2 years after the procedure ( P =0.005). Surgical success was achieved in 87% of the patients at their last follow-up visit. There was a nonsignificant decrease in the mean number of glaucoma medications from 2.5±0.8 to 2.0±1.0 at 2 years ( P =0.48). No major intraoperative or postoperative complications were noted. Conclusion: UCP-HIFU treatment is an effective, safe, and well-tolerated method to reduce IOP in patients with moderate glaucoma. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Journal of glaucoma. Volume 29:Issue 7(2020)
- Journal:
- Journal of glaucoma
- Issue:
- Volume 29:Issue 7(2020)
- Issue Display:
- Volume 29, Issue 7 (2020)
- Year:
- 2020
- Volume:
- 29
- Issue:
- 7
- Issue Sort Value:
- 2020-0029-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-07
- Subjects:
- glaucoma -- high-intensity focused ultrasound -- intraocular pressure -- ciliary body
Glaucoma -- Periodicals
617.741005 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00061198-000000000-00000 ↗
http://www.glaucomajournal.com ↗
http://journals.lww.com/glaucomajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IJG.0000000000001497 ↗
- Languages:
- English
- ISSNs:
- 1057-0829
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4996.230000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13771.xml