Diagnostic Accuracy of Diaphragm Ultrasound in Detecting and Characterizing Patient–Ventilator Asynchronies during Noninvasive Ventilation. (June 2020)
- Record Type:
- Journal Article
- Title:
- Diagnostic Accuracy of Diaphragm Ultrasound in Detecting and Characterizing Patient–Ventilator Asynchronies during Noninvasive Ventilation. (June 2020)
- Main Title:
- Diagnostic Accuracy of Diaphragm Ultrasound in Detecting and Characterizing Patient–Ventilator Asynchronies during Noninvasive Ventilation
- Authors:
- Vivier, Emmanuel
Haudebourg, Anne Fleur
Le Corvoisier, Philippe
Mekontso Dessap, Armand
Carteaux, Guillaume - Abstract:
- Abstract : Background: Management of acute respiratory failure by noninvasive ventilation is often associated with asynchronies, like autotriggering or delayed cycling, incurred by leaks from the interface. These events are likely to impair patient's tolerance and to compromise noninvasive ventilation. The development of methods for easy detection and monitoring of asynchronies is therefore necessary. The authors describe two new methods to detect patient–ventilator asynchronies, based on ultrasound analysis of diaphragm excursion or thickening combined with airway pressure. The authors tested these methods in a diagnostic accuracy study. Methods: Fifteen healthy subjects were placed under noninvasive ventilation and subjected to artificially induced leaks in order to generate the main asynchronies (autotriggering or delayed cycling) at event-appropriate times of the respiratory cycle. Asynchronies were identified and characterized by conjoint assessment of ultrasound records and airway pressure waveforms; both were visualized on the ultrasound screen. The performance and accuracy of diaphragm excursion and thickening to detect each asynchrony were compared with a "control method" of flow/pressure tracings alone, and a "working standard method" combining flow, airway pressure, and diaphragm electromyography signals analyses. Results: Ultrasound recordings were performed for the 15 volunteers, unlike electromyography recordings which could be collected in only 9 of 15Abstract : Background: Management of acute respiratory failure by noninvasive ventilation is often associated with asynchronies, like autotriggering or delayed cycling, incurred by leaks from the interface. These events are likely to impair patient's tolerance and to compromise noninvasive ventilation. The development of methods for easy detection and monitoring of asynchronies is therefore necessary. The authors describe two new methods to detect patient–ventilator asynchronies, based on ultrasound analysis of diaphragm excursion or thickening combined with airway pressure. The authors tested these methods in a diagnostic accuracy study. Methods: Fifteen healthy subjects were placed under noninvasive ventilation and subjected to artificially induced leaks in order to generate the main asynchronies (autotriggering or delayed cycling) at event-appropriate times of the respiratory cycle. Asynchronies were identified and characterized by conjoint assessment of ultrasound records and airway pressure waveforms; both were visualized on the ultrasound screen. The performance and accuracy of diaphragm excursion and thickening to detect each asynchrony were compared with a "control method" of flow/pressure tracings alone, and a "working standard method" combining flow, airway pressure, and diaphragm electromyography signals analyses. Results: Ultrasound recordings were performed for the 15 volunteers, unlike electromyography recordings which could be collected in only 9 of 15 patients (60%). Autotriggering was correctly identified by continuous recording of electromyography, excursion, thickening, and flow/pressure tracings with sensitivity of 93% (95% CI, 89–97%), 94% (95% CI, 91–98%), 91% (95% CI, 87–96%), and 79% (95% CI, 75–84%), respectively. Delayed cycling was detected by electromyography, excursion, thickening, and flow/pressure tracings with sensitivity of 84% (95% CI, 77–90%), 86% (95% CI, 80–93%), 89% (95% CI, 83–94%), and 67% (95% CI, 61–73%), respectively. Conclusions: Ultrasound is a simple, bedside adjustable, clinical tool to detect the majority of patient–ventilator asynchronies associated with noninvasive ventilation leaks, provided that it is possible to visualize the airway pressure curve on the ultrasound machine screen. Ultrasound detection of autotriggering and delayed cycling is more accurate than isolated observation of pressure and flow tracings, and more feasible than electromyogram. Abstract : In 15 healthy volunteers ultrasound assessment of diaphragm excursion and thickening detected noninvasive ventilator asynchronies with high sensitivity and specificity when compared with assessment of respiratory flow/pressure tracings. Surface diaphragm electromyography also had significantly higher sensitivity and specificity for detecting noninvasive ventilator asynchronies, but was only able to be successfully implemented in 60% of the study patients, suggesting that ultrasound assessment of diaphragm excursion and thickening is a more feasible technique for detecting ventilator asynchrony.Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Anesthesiology. Volume 132:Number 6(2020)
- Journal:
- Anesthesiology
- Issue:
- Volume 132:Number 6(2020)
- Issue Display:
- Volume 132, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 132
- Issue:
- 6
- Issue Sort Value:
- 2020-0132-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-06
- Subjects:
- Anesthesiology -- Periodicals
Anesthetics -- Periodicals
Anesthesia -- Periodicals
617.9605 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00000542-000000000-00000 ↗
http://www.mdconsult.com/public/search?search_type=journal&j_sort=pub_date&j_issn=0003-3022 ↗
http://www.anesthesiology.org ↗
http://journals.lww.com ↗
http://journals.lww.com/anesthesiology/pages/default.aspx ↗ - DOI:
- 10.1097/ALN.0000000000003239 ↗
- Languages:
- English
- ISSNs:
- 0003-3022
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0900.600000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13763.xml