- Shikano, Kohei
Ishii, Daisuke
Umimura, Tomotaka
Rakuman, Shintaro
Maki, Satoshi
Kasai, Hajime
Orita, Sumihisa
Iwasawa, Shunichiro
Sugiura, Toshihiko
Ohtori, Seiji
Tatsumi, Koichiro - Abstract:
- Abstract : A 70‐year‐old male was referred to our hospital with lower limb muscle weakness and numbness of the left hand. The patient had previously been diagnosed seven years ago with lung cancer accompanied by central airway obstruction and had received chemoradiotherapy following placement of a metallic stent. Computed tomography (CT) scan revealed an osteolytic lesion which was adjacent to the fractured stent. T2‐weighted magnetic resonance imaging (MRI) demonstrated high signal intensity in the disc space. The patient was diagnosed with spondylodiscitis and spinal epidural abscess related to the airway stent. Despite hemilaminectomy, laminectomy and long‐term antibiotic therapy, the infection was uncontrolled. Moreover, osteolytic destruction and kyphotic deformity progressed. Removal of the airway stent was necessary; however, it was impossible because bronchial resection was required and the risk of mediastinal injury was considered to be high. The patient subsequently received palliative care. Long‐term airway stenting can cause spondylodiscitis and spinal epidural abscess. Indications for the placement of metallic stents for malignant central airway obstruction should be carefully evaluated after considering the difficulty in removal and the long‐term risk of severe complications. Key points: Significant findings of the study Long‐term placement and fracture of the airway stent can cause spondylodiscitis and spinal epidural abscess. What this study adds TheAbstract : A 70‐year‐old male was referred to our hospital with lower limb muscle weakness and numbness of the left hand. The patient had previously been diagnosed seven years ago with lung cancer accompanied by central airway obstruction and had received chemoradiotherapy following placement of a metallic stent. Computed tomography (CT) scan revealed an osteolytic lesion which was adjacent to the fractured stent. T2‐weighted magnetic resonance imaging (MRI) demonstrated high signal intensity in the disc space. The patient was diagnosed with spondylodiscitis and spinal epidural abscess related to the airway stent. Despite hemilaminectomy, laminectomy and long‐term antibiotic therapy, the infection was uncontrolled. Moreover, osteolytic destruction and kyphotic deformity progressed. Removal of the airway stent was necessary; however, it was impossible because bronchial resection was required and the risk of mediastinal injury was considered to be high. The patient subsequently received palliative care. Long‐term airway stenting can cause spondylodiscitis and spinal epidural abscess. Indications for the placement of metallic stents for malignant central airway obstruction should be carefully evaluated after considering the difficulty in removal and the long‐term risk of severe complications. Key points: Significant findings of the study Long‐term placement and fracture of the airway stent can cause spondylodiscitis and spinal epidural abscess. What this study adds The indication of placement of a metallic stent for malignant central airway obstruction should be considered with caution, especially if long‐term survival can be expected. … (more)
- Is Part Of:
- Thoracic cancer. Volume 11:Issue 8(2020)
- Journal:
- Thoracic cancer
- Issue:
- Volume 11:Issue 8(2020)
- Issue Display:
- Volume 11, Issue 8 (2020)
- Year:
- 2020
- Volume:
- 11
- Issue:
- 8
- Issue Sort Value:
- 2020-0011-0008-0000
- Page Start:
- 2343
- Page End:
- 2346
- Publication Date:
- 2020-06-24
- Subjects:
- Airway obstruction -- epidural abscess -- lung cancer -- self expandable metal stent
Chest -- Cancer -- Periodicals
Chest -- Cancer -- Treatment -- Periodicals
Chest -- Surgery -- Periodicals
616.99494005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/%28ISSN%291759-7714;jsessionid=9202029487E02D838DF722140677202D.d04t01 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1759-7714 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.wiley.com/bw/journal.asp?ref=1759-7706&site=1 ↗ - DOI:
- 10.1111/1759-7714.13530 ↗
- Languages:
- English
- ISSNs:
- 1759-7706
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8820.242500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13754.xml