Metal artifact reduction of orthopedics metal artifact reduction algorithm in total hip and knee arthroplasty. Issue 11 (March 2020)
- Record Type:
- Journal Article
- Title:
- Metal artifact reduction of orthopedics metal artifact reduction algorithm in total hip and knee arthroplasty. Issue 11 (March 2020)
- Main Title:
- Metal artifact reduction of orthopedics metal artifact reduction algorithm in total hip and knee arthroplasty
- Authors:
- Zhang, Kesong
Han, Qing
Xu, Xiaolin
Jiang, Hao
Ma, Lin
Zhang, Yong
Yang, Kerong
Chen, Bingpeng
Wang, Jincheng - Other Names:
- Lalwani. Neeraj section editor.
- Abstract:
- Abstract : Abstract: The purpose of this study was to investigate metal artifact reduction effect of orthopedics metal artifact reduction (O-Mar) algorithm in computer tomography (CT) image of patients who have undergone total hip arthroplasty (THA) or total knee arthroplasty (TKA). 35 cases of patients who underwent TKA or THA have been recruited in this study. CT image of hip or knee joint was obtained with Philips 256-row CT scanner. Tube voltages of 120 and 140 kilovolt peak (KVP) were set. Afterwards, CT image was reconstructed by O-Mar algorithm to reduce metal artifact. Grade of image quality and severity of metal artifact would be taken into qualitative evaluation. While, quantitative evaluation mainly included measurement of metal artifact volume and 2D measurement of average CT value in region of interest (ROI). The visibility of interface between bone–prostheses was also estimated. Result of qualitative analysis indicated that score of CT quality was improved and grade of metal artifact was decreased significantly with O-Mar. Quantitative analysis illustrated that volume of beam-hardening (B-H) metal artifact decreased remarkably after reconstruction of O-Mar ( P < .001). In addition, O-Mar algorithm reduced 83.3% to 83.7% volume of photon-starvation (P-S) metal artifact. As for result of 2D measurement, CT value in ROI was closer to standard value in O-Mar group CT image ( P < .001). Meanwhile, error of CT value also decreased significantly after reconstructionAbstract : Abstract: The purpose of this study was to investigate metal artifact reduction effect of orthopedics metal artifact reduction (O-Mar) algorithm in computer tomography (CT) image of patients who have undergone total hip arthroplasty (THA) or total knee arthroplasty (TKA). 35 cases of patients who underwent TKA or THA have been recruited in this study. CT image of hip or knee joint was obtained with Philips 256-row CT scanner. Tube voltages of 120 and 140 kilovolt peak (KVP) were set. Afterwards, CT image was reconstructed by O-Mar algorithm to reduce metal artifact. Grade of image quality and severity of metal artifact would be taken into qualitative evaluation. While, quantitative evaluation mainly included measurement of metal artifact volume and 2D measurement of average CT value in region of interest (ROI). The visibility of interface between bone–prostheses was also estimated. Result of qualitative analysis indicated that score of CT quality was improved and grade of metal artifact was decreased significantly with O-Mar. Quantitative analysis illustrated that volume of beam-hardening (B-H) metal artifact decreased remarkably after reconstruction of O-Mar ( P < .001). In addition, O-Mar algorithm reduced 83.3% to 83.7% volume of photon-starvation (P-S) metal artifact. As for result of 2D measurement, CT value in ROI was closer to standard value in O-Mar group CT image ( P < .001). Meanwhile, error of CT value also decreased significantly after reconstruction of O-Mar algorithm. Visibility rate of bone–prosthesis interface improved from 34.3% (Non-O-Mar) to 66.7% (O-Mar). O-Mar algorithm could significantly reduce metal artifact in CT image of THA and TKA in both 2D and three-dimensional (3D) level. Therefore, better image quality and visibility of bone–prostheses interface could be presented. In this study, O-Mar was proved as an efficient metal artifact reduction method in CT image of THA and TKA. … (more)
- Is Part Of:
- Medicine. Volume 99:Issue 11(2020)
- Journal:
- Medicine
- Issue:
- Volume 99:Issue 11(2020)
- Issue Display:
- Volume 99, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 99
- Issue:
- 11
- Issue Sort Value:
- 2020-0099-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-03
- Subjects:
- arthroplasty -- computer tomography -- diagnostic accuracy -- metal artifact -- O-Mar
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000019268 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13753.xml