Reliability of Point-of-Care International Normalized Ratio Measurements in Various Patient Populations. Issue 1 (March 2020)
- Record Type:
- Journal Article
- Title:
- Reliability of Point-of-Care International Normalized Ratio Measurements in Various Patient Populations. Issue 1 (March 2020)
- Main Title:
- Reliability of Point-of-Care International Normalized Ratio Measurements in Various Patient Populations
- Authors:
- Arline, Kim
Rodriguez, Cesar
Sanchez, Krista - Abstract:
- Abstract : Purpose: The aim of this study was to determine if the Coagsense point-of-care (POC) instrument provides more reliable international normalized ratio (INR) measurements than Coagucheck XS POC in comparison to the Stago laboratory instrument in different disease states. Methods: This was a prospective study of outpatient warfarin patients comparing venous Stago INR to fingerstick INR on the Coagsense and Coagucheck XS POC meters. Patients were invited to study if they had an of INR 2.0 to 5.0 and had a medical history of antiphospholipid syndrome, hypercoagulable disorder, autoimmune condition, peripheral vascular disease, mechanical heart valve, atrial fibrillation, or deep vein thrombosis/pulmonary embolism/cerebrovascular accident history. Results: Seventy-seven patients were enrolled. Coagsense correlated well (92% of INRs within 20% of Stago, 64% of INRs within 0.2 of Stago, overall INR bias of 0.1 or 4%). Six patients had greater than 20% POC INR bias, which could have resulted in 4 warfarin dosing errors. Coagucheck XS INRs correlated poorly (49% within 20% of Stago, 10% of INRs were within 0.2 of Stago, overall INR bias of 0.66 or 25.7%). Forty-one patients had greater than 20% POC INR bias in all diseases, which could have resulted in 28 warfarin dosing errors. The average Coagucheck XS INR bias (0.46–1.3 INR) increased with each 0.5 increase in laboratory INR, whereas Coagsense bias remained stable (0.1–0.25) as INR increased up to 4.3. Two patientsAbstract : Purpose: The aim of this study was to determine if the Coagsense point-of-care (POC) instrument provides more reliable international normalized ratio (INR) measurements than Coagucheck XS POC in comparison to the Stago laboratory instrument in different disease states. Methods: This was a prospective study of outpatient warfarin patients comparing venous Stago INR to fingerstick INR on the Coagsense and Coagucheck XS POC meters. Patients were invited to study if they had an of INR 2.0 to 5.0 and had a medical history of antiphospholipid syndrome, hypercoagulable disorder, autoimmune condition, peripheral vascular disease, mechanical heart valve, atrial fibrillation, or deep vein thrombosis/pulmonary embolism/cerebrovascular accident history. Results: Seventy-seven patients were enrolled. Coagsense correlated well (92% of INRs within 20% of Stago, 64% of INRs within 0.2 of Stago, overall INR bias of 0.1 or 4%). Six patients had greater than 20% POC INR bias, which could have resulted in 4 warfarin dosing errors. Coagucheck XS INRs correlated poorly (49% within 20% of Stago, 10% of INRs were within 0.2 of Stago, overall INR bias of 0.66 or 25.7%). Forty-one patients had greater than 20% POC INR bias in all diseases, which could have resulted in 28 warfarin dosing errors. The average Coagucheck XS INR bias (0.46–1.3 INR) increased with each 0.5 increase in laboratory INR, whereas Coagsense bias remained stable (0.1–0.25) as INR increased up to 4.3. Two patients correlated well on Coagucheck XS but not Coagsense. Conclusion: Coagsense correlated better than Coagucheck XS and did not show increasing bias as INR increased. Both POC instruments had higher INR variability in 4 disease states (antiphospholipid syndrome, autoimmune, peripheral vascular disease, and hypercoagulable). Patient-specific laboratory correlations may be needed on each POC device. … (more)
- Is Part Of:
- Point of care. Volume 19:Issue 1(2020)
- Journal:
- Point of care
- Issue:
- Volume 19:Issue 1(2020)
- Issue Display:
- Volume 19, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 19
- Issue:
- 1
- Issue Sort Value:
- 2020-0019-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-03
- Subjects:
- anticoagulation -- international normalized ratio reliability -- point-of-care -- Coagsense -- Coagucheck XS -- Stago -- warfarin -- antiphospholipid syndrome -- Hypercoagulable disorders
Point-of-care testing -- Periodicals
Point-of-Care Systems -- standards -- Periodicals
616.075 - Journal URLs:
- http://www.poctjournal.com ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00134384-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/POC.0000000000000197 ↗
- Languages:
- English
- ISSNs:
- 1533-029X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6541.842900
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13748.xml