Automated Noncontact Ultrasound Imaging and Ablation System for the Treatment of Atrial Fibrillation: Outcomes of the First-in-Human VALUE Trial. (March 2020)
- Record Type:
- Journal Article
- Title:
- Automated Noncontact Ultrasound Imaging and Ablation System for the Treatment of Atrial Fibrillation: Outcomes of the First-in-Human VALUE Trial. (March 2020)
- Main Title:
- Automated Noncontact Ultrasound Imaging and Ablation System for the Treatment of Atrial Fibrillation
- Authors:
- Turagam, Mohit K.
Petru, Jan
Neuzil, Petr
Kakita, Ken
Kralovec, Stepan
Harari, David
Phillips, Patrick
Piazza, Danielo
Whang, William
Dukkipati, Srinivas R.
Reddy, Vivek Y. - Abstract:
- Abstract : Background: Catheter ablation for atrial fibrillation (AF) using point-by-point radiofrequency energy or single-application one-shot balloons is either technically challenging or have limited ability to accommodate variable patient anatomy to achieve acute and durable pulmonary vein (PV) isolation. A novel ablation system employs low intensity collimated ultrasound (LICU)-guided anatomic mapping and robotic ablation to isolate PVs. In this first-in-human, single-center, multioperator trial, VALUE trial (VytronUS Ablation System for Treatment of Paroxysmal Atrial Fibrillation; NCT03639597) in patients with paroxysmal atrial fibrillation, this LICU system was evaluated to determine its safety, effectiveness in PV isolation, and freedom from recurrent atrial arrhythmias. Methods: In the enrolled 52 patients with paroxysmal atrial fibrillation, ultrasound M-mode–based left atrial anatomies were successfully created, and ablation was performed under robotic control along an operator-defined lesion path. The LICU system software advanced over the course of the study: the last 13 patients were ablated with enhanced software. Results: Acute PV isolation was achieved in 98% of PVs—using LICU-only in 77.3% (153/198) of PVs and requiring touch-up with a standard radiofrequency ablation catheter in 22.7% (45/198) PVs. The touch-up rate decreased to 5.8% (3/52) in patients undergoing LICU-ablation with enhanced software. Freedom from atrial arrhythmia recurrence was 79.6%Abstract : Background: Catheter ablation for atrial fibrillation (AF) using point-by-point radiofrequency energy or single-application one-shot balloons is either technically challenging or have limited ability to accommodate variable patient anatomy to achieve acute and durable pulmonary vein (PV) isolation. A novel ablation system employs low intensity collimated ultrasound (LICU)-guided anatomic mapping and robotic ablation to isolate PVs. In this first-in-human, single-center, multioperator trial, VALUE trial (VytronUS Ablation System for Treatment of Paroxysmal Atrial Fibrillation; NCT03639597) in patients with paroxysmal atrial fibrillation, this LICU system was evaluated to determine its safety, effectiveness in PV isolation, and freedom from recurrent atrial arrhythmias. Methods: In the enrolled 52 patients with paroxysmal atrial fibrillation, ultrasound M-mode–based left atrial anatomies were successfully created, and ablation was performed under robotic control along an operator-defined lesion path. The LICU system software advanced over the course of the study: the last 13 patients were ablated with enhanced software. Results: Acute PV isolation was achieved in 98% of PVs—using LICU-only in 77.3% (153/198) of PVs and requiring touch-up with a standard radiofrequency ablation catheter in 22.7% (45/198) PVs. The touch-up rate decreased to 5.8% (3/52) in patients undergoing LICU-ablation with enhanced software. Freedom from atrial arrhythmia recurrence was 79.6% (39/49 patients) at 12 months or 92.3% (12/13 patients) with the enhanced software. Major adverse events occurred in 3 patients (5.8%): one had transient diaphragmatic paralysis, one vascular access complication, and one had transient ST-segment elevation from air-embolism, without sequelae. Conclusions: In this first-in-human study, low- intensity collimated ultrasound-guided anatomic mapping and robotic ablation allows PV isolation with good chronic safety; PV isolation success is improving with device enhancements. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03639597. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 13:Number 3(2020)
- Journal:
- Circulation
- Issue:
- Volume 13:Number 3(2020)
- Issue Display:
- Volume 13, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 13
- Issue:
- 3
- Issue Sort Value:
- 2020-0013-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-03
- Subjects:
- atrial fibrillation -- catheter -- catheter ablation -- pulmonary veins -- software
Arrhythmia -- Periodicals
Heart -- Electric properties -- Periodicals
616.128 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01337493-000000000-00000 ↗
http://circep.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCEP.119.007917 ↗
- Languages:
- English
- ISSNs:
- 1941-3149
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13754.xml