Non-randomized safety and performance evaluation of the av-Guardian vascular access system. Issue 5 (September 2020)
- Record Type:
- Journal Article
- Title:
- Non-randomized safety and performance evaluation of the av-Guardian vascular access system. Issue 5 (September 2020)
- Main Title:
- Non-randomized safety and performance evaluation of the av-Guardian vascular access system
- Authors:
- Tan, Chieh Suai
Tan, Seck Guan
Wong, Chi Leung Julian
Wee, Bernard
Wong, Weng Kin
Choke, Edward Tieng Chek
Tan, Ru Yu
Liu, Peiyun
Homer-Vanniasinkam, Shervanthi
Lau, Titus
Choong, Lina Hui Lin - Abstract:
- Introduction: The ability to successfully cannulate the arteriovenous fistula reliably is a critical step in the delivery of hemodialysis therapy. The av-Guardian vascular access system (Advent Access, Singapore) is designed to overcome the technical barrier to establishing reliable blunt needle access in patients with mature arteriovenous fistula. Methods: This was a first-in-man, prospective, non-randomized trial (registered on the Australian New Zealand Clinical Trial Registry (ACTRN12617000501347)) performed to assess the safety and feasibility of achieving repeatable successful cannulation via av-Guardian vascular access system to facilitate blunt needling in patients with mature arteriovenous fistula. The primary endpoints of the study included rate of successful hemodialysis sessions via av-Guardian vascular access system cannulation over 3 months and safety of the implants. Results: A total of six patients (four patients with brachiocephalic and two with radiocephalic arteriovenous fistula) were enrolled in the study. A pair of av-Guardian vascular access system were implanted, one each at the arterial and venous cannulation sites, under local anesthesia. Overall, the rate of successful cannulation through the av-Guardian vascular access system over 3 months in 216 hemodialysis sessions was 98.1% (212/216) at the arterial site and 94.4% (204/216) at the venous site. Significantly, 90% and 85.5% of the cannulations at the arterial and venous site, respectively, wereIntroduction: The ability to successfully cannulate the arteriovenous fistula reliably is a critical step in the delivery of hemodialysis therapy. The av-Guardian vascular access system (Advent Access, Singapore) is designed to overcome the technical barrier to establishing reliable blunt needle access in patients with mature arteriovenous fistula. Methods: This was a first-in-man, prospective, non-randomized trial (registered on the Australian New Zealand Clinical Trial Registry (ACTRN12617000501347)) performed to assess the safety and feasibility of achieving repeatable successful cannulation via av-Guardian vascular access system to facilitate blunt needling in patients with mature arteriovenous fistula. The primary endpoints of the study included rate of successful hemodialysis sessions via av-Guardian vascular access system cannulation over 3 months and safety of the implants. Results: A total of six patients (four patients with brachiocephalic and two with radiocephalic arteriovenous fistula) were enrolled in the study. A pair of av-Guardian vascular access system were implanted, one each at the arterial and venous cannulation sites, under local anesthesia. Overall, the rate of successful cannulation through the av-Guardian vascular access system over 3 months in 216 hemodialysis sessions was 98.1% (212/216) at the arterial site and 94.4% (204/216) at the venous site. Significantly, 90% and 85.5% of the cannulations at the arterial and venous site, respectively, were successful at first attempt. Blood flow rates within the arteriovenous fistula were unaffected by the devices. Conclusion: The results demonstrated the safety and feasibility of a subcutaneously implanted, extravascular device in achieving repeatable successful cannulation via a constant site, to facilitate blunt needling in matured arteriovenous fistula in limited number of patients. … (more)
- Is Part Of:
- Journal of vascular access. Volume 21:Issue 5(2020)
- Journal:
- Journal of vascular access
- Issue:
- Volume 21:Issue 5(2020)
- Issue Display:
- Volume 21, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 21
- Issue:
- 5
- Issue Sort Value:
- 2020-0021-0005-0000
- Page Start:
- 665
- Page End:
- 672
- Publication Date:
- 2020-09
- Subjects:
- Hemodialysis -- arteriovenous fistula -- cannulation techniques -- novel device
Arterial catheterization -- Periodicals
Intravenous catheterization -- Periodicals
612.13 - Journal URLs:
- http://journals.sagepub.com/home/jva ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1129729819898306 ↗
- Languages:
- English
- ISSNs:
- 1129-7298
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13745.xml