Dual Versus Single-Plate Fixation of Midshaft Clavicular Fractures: A Retrospective Comparative Study. Issue 2 (April 2020)
- Record Type:
- Journal Article
- Title:
- Dual Versus Single-Plate Fixation of Midshaft Clavicular Fractures: A Retrospective Comparative Study. Issue 2 (April 2020)
- Main Title:
- Dual Versus Single-Plate Fixation of Midshaft Clavicular Fractures
- Authors:
- Allis, J. Benjamin
Cheung, Edward C.
Farrell, Eric D.
Johnson, Eric E.
Jeffcoat, Devon M. - Abstract:
- Abstract : Background: Implant-related symptoms are the most common reason for reoperation after open reduction and internal fixation (ORIF) of midshaft clavicular fractures. Dual mini-fragment plate fixation is a relatively new solution that may decrease implant prominence while maintaining fixation strength and function. There are minimal published data comparing reoperation rates and clinical outcomes between single, superior-plate constructs and dual mini-fragment plate constructs in the fixation of midshaft clavicular fractures. We hypothesized that reducing plate size with the use of dual mini-fragment plating compared with standard, 3.5-mm, superior plating would minimize implant symptoms and the corresponding need for reoperation while still providing sufficient fixation to allow fracture-healing and return to function. Methods: We retrospectively reviewed the cases of 44 consecutive patients who underwent ORIF of displaced midshaft clavicular fractures utilizing either a single, 3.5-mm, superior plate construct (21 patients) or a dual, 2.7-mm and 2.4-mm, plate construct (23 patients). Outcomes at a minimum of 2 years were assessed. Primary outcome measures included reoperation for any reason and the American Shoulder and Elbow Surgeons (ASES) Standardized Shoulder Assessment Form, patient self-report section. Results: There was a 100% union rate in both groups. None (0%) of the 23 patients who received the dual (2.7-mm and 2.4-mm) plate construct and 6 (29%) of theAbstract : Background: Implant-related symptoms are the most common reason for reoperation after open reduction and internal fixation (ORIF) of midshaft clavicular fractures. Dual mini-fragment plate fixation is a relatively new solution that may decrease implant prominence while maintaining fixation strength and function. There are minimal published data comparing reoperation rates and clinical outcomes between single, superior-plate constructs and dual mini-fragment plate constructs in the fixation of midshaft clavicular fractures. We hypothesized that reducing plate size with the use of dual mini-fragment plating compared with standard, 3.5-mm, superior plating would minimize implant symptoms and the corresponding need for reoperation while still providing sufficient fixation to allow fracture-healing and return to function. Methods: We retrospectively reviewed the cases of 44 consecutive patients who underwent ORIF of displaced midshaft clavicular fractures utilizing either a single, 3.5-mm, superior plate construct (21 patients) or a dual, 2.7-mm and 2.4-mm, plate construct (23 patients). Outcomes at a minimum of 2 years were assessed. Primary outcome measures included reoperation for any reason and the American Shoulder and Elbow Surgeons (ASES) Standardized Shoulder Assessment Form, patient self-report section. Results: There was a 100% union rate in both groups. None (0%) of the 23 patients who received the dual (2.7-mm and 2.4-mm) plate construct and 6 (29%) of the 21 patients who received the single (3.5-mm) plate construct underwent reoperation for implant-related symptoms. Using a Fisher exact test, the rate of reoperation was compared between the groups, and the difference was found to be significant (p = 0.008). Using an unpaired t test, the difference in mean ASES scores was not significant (p = 0.138) between the dual-plate group (98 of 100) and the single superior plate group (96 of 100) with retained implants. Conclusions: In our comparative retrospective series, dual fixation utilizing a 2.7-mm superior plate and a 2.4-mm anterior plate for the treatment of displaced midshaft clavicular fractures was associated with a significantly lower rate of reoperation when compared with single, 3.5-mm, superior plate fixation. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence. … (more)
- Is Part Of:
- JB & JS open access. Volume 5:Issue 2(2020)
- Journal:
- JB & JS open access
- Issue:
- Volume 5:Issue 2(2020)
- Issue Display:
- Volume 5, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 5
- Issue:
- 2
- Issue Sort Value:
- 2020-0005-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-04
- Subjects:
- Orthopedic surgery -- Periodicals
Orthopedic surgery
Periodicals
617.4705 - Journal URLs:
- http://journals.lww.com/jbjsoa/Pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.2106/JBJS.OA.19.00043 ↗
- Languages:
- English
- ISSNs:
- 2472-7245
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13744.xml