Mechanism of Drug-Eluting Absorbable Metal Scaffold Restenosis: A Serial Optical Coherence Tomography Study. (March 2020)
- Record Type:
- Journal Article
- Title:
- Mechanism of Drug-Eluting Absorbable Metal Scaffold Restenosis: A Serial Optical Coherence Tomography Study. (March 2020)
- Main Title:
- Mechanism of Drug-Eluting Absorbable Metal Scaffold Restenosis
- Authors:
- Ueki, Yasushi
Räber, Lorenz
Otsuka, Tatsuhiko
Rai, Himanshu
Losdat, Sylvain
Windecker, Stephan
Garcia-Garcia, Hector M.
Landmesser, Ulf
Koolen, Jacques
Byrne, Robert
Haude, Michael
Joner, Michael - Abstract:
- Abstract : Background: The pathomechanisms underlying restenosis of the bioabsorbable sirolimus-eluting metallic scaffold (Magmaris) remain unknown. Using serial optical coherence tomography, we investigated causes of restenosis, including the contribution of late scaffold recoil versus neointimal hyperplasia. Methods: Patients enrolled in BIOSOLVE-II undergoing serial angiography and optical coherence tomography (post-intervention and follow-up: 6 months and/or 1 year) were analyzed. Patients were divided into 2 groups according to angiographic in-scaffold late lumen loss (LLL) <0.5 or ≥0.5 mm. End points were late absolute scaffold recoil and neointimal hyperplasia area as assessed by optical coherence tomography. Results: Serial data were available for analysis from 70 patients (LLL <0.5 mm: n=41; LLL ≥0.5 mm: n=29). Patient and lesion characteristics were comparable, and there was no significant difference in mean and minimal scaffold area between groups at post-intervention. Late absolute scaffold recoil was less among patients with LLL <0.5 mm (0.53±0.68 mm 2 ) compared with those with LLL ≥0.5 mm (1.48±1.20 mm 2 ; P <0.001). Neointimal hyperplasia area was smaller among patients with LLL <0.5 mm at follow-up (1.47±0.33 mm 2 ) compared with patients with LLL ≥0.5 mm (1.68±0.34 mm 2 ; P =0.013). In a matched-frame analysis (post-intervention and follow-up), late absolute scaffold recoil varied according to the underlying plaque type (lipid: 0.63±1.23 mm 2 ; calcified:Abstract : Background: The pathomechanisms underlying restenosis of the bioabsorbable sirolimus-eluting metallic scaffold (Magmaris) remain unknown. Using serial optical coherence tomography, we investigated causes of restenosis, including the contribution of late scaffold recoil versus neointimal hyperplasia. Methods: Patients enrolled in BIOSOLVE-II undergoing serial angiography and optical coherence tomography (post-intervention and follow-up: 6 months and/or 1 year) were analyzed. Patients were divided into 2 groups according to angiographic in-scaffold late lumen loss (LLL) <0.5 or ≥0.5 mm. End points were late absolute scaffold recoil and neointimal hyperplasia area as assessed by optical coherence tomography. Results: Serial data were available for analysis from 70 patients (LLL <0.5 mm: n=41; LLL ≥0.5 mm: n=29). Patient and lesion characteristics were comparable, and there was no significant difference in mean and minimal scaffold area between groups at post-intervention. Late absolute scaffold recoil was less among patients with LLL <0.5 mm (0.53±0.68 mm 2 ) compared with those with LLL ≥0.5 mm (1.48±1.20 mm 2 ; P <0.001). Neointimal hyperplasia area was smaller among patients with LLL <0.5 mm at follow-up (1.47±0.33 mm 2 ) compared with patients with LLL ≥0.5 mm (1.68±0.34 mm 2 ; P =0.013). In a matched-frame analysis (post-intervention and follow-up), late absolute scaffold recoil varied according to the underlying plaque type (lipid: 0.63±1.23 mm 2 ; calcified: 0.81±1.44 mm 2 ; and fibrous: 1.20±1.52 mm 2 ; P <0.001), while there was no difference with regards to neointimal hyperplasia area ( P =0.132). Conclusions: In addition to neointimal hyperplasia, late scaffold recoil contributed significantly to LLL of sirolimus-eluting absorbable metal scaffolds. The extent of late scaffold recoil was dependent on the underlying plaque morphology and was the highest among fibrotic lesions. Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT01960504. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 13:Number 3(2020)
- Journal:
- Circulation
- Issue:
- Volume 13:Number 3(2020)
- Issue Display:
- Volume 13, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 13
- Issue:
- 3
- Issue Sort Value:
- 2020-0013-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-03
- Subjects:
- angiography -- follow-up -- hyperplasia -- sirolimus -- tomography, optical coherence
Cardiovascular system -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Treatment -- Periodicals
616.105 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=01337495-000000000-00000 ↗
http://circinterventions.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCINTERVENTIONS.119.008657 ↗
- Languages:
- English
- ISSNs:
- 1941-7640
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262560
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13739.xml