The impact of echocardiographic parameter ratio of E/E' on the late recurrence paroxysmal atrial fibrillation in patients accepted radiofrequency catheter ablation: A retrospective clinical study. Issue 17 (April 2020)
- Record Type:
- Journal Article
- Title:
- The impact of echocardiographic parameter ratio of E/E' on the late recurrence paroxysmal atrial fibrillation in patients accepted radiofrequency catheter ablation: A retrospective clinical study. Issue 17 (April 2020)
- Main Title:
- The impact of echocardiographic parameter ratio of E/E' on the late recurrence paroxysmal atrial fibrillation in patients accepted radiofrequency catheter ablation
- Authors:
- Gong, Ke-Zeng
Yan, Qin-Dan
Huang, Rong-Da
Chen, Jian-Hua
Chen, Xue-Hai
Wang, Wei-Wei
Xu, Zhe
Chen, Liang-Long
Fan, Lin
Zhang, Fei-Long - Other Names:
- Gulletta. Simone section editor.
- Abstract:
- Abstract : Abstract: This study aimed to evaluate the impact of the echocardiographic parameter ratio E/E' on the late recurrence of paroxysmal atrial fibrillation in patients after receiving radiofrequency catheter ablation. We retrospectively examined total of 288 paroxysmal atrial fibrillation (PAF) patients that underwent a preliminary radiofrequency catheter ablation (RFCA) in our hospital. During the first phase in this study, the patients were divided into 2 groups upon AF recurrence after RFCA: Recurrent group, n = 67 patients with rapid trial arrhythmia that lasted for more than 30 seconds at 3 months after RFCA and the Nonrecurrent group, n = 221. The clinical conditions were compared between the 2 groups. During the second phase of this study, based on the results in the first phase, the patients were divided into another 2 groups according to whether the ratio of E/E' ≥13 .45: Higher ratio of E/E' group, n = 55 and Lower ratio of E/E' group n = 233. The late AF recurrent rates were also compared between the 2 groups. During the first phase, the univariate analysis indicated that the risk factors( P < .05)for PAF late recurrence included early recurrence, E', and the ratio E/E'. The Cox multivariate analysis showed that the ratio of E/E' and early recurrence were the independent predictors for late PAF recurrence. The ratio of E/E' that was cut off at 13.45 also predicted atrial tachyarrhythmia recurrence with 40.3% sensitivity and 87.3% specificity. In theAbstract : Abstract: This study aimed to evaluate the impact of the echocardiographic parameter ratio E/E' on the late recurrence of paroxysmal atrial fibrillation in patients after receiving radiofrequency catheter ablation. We retrospectively examined total of 288 paroxysmal atrial fibrillation (PAF) patients that underwent a preliminary radiofrequency catheter ablation (RFCA) in our hospital. During the first phase in this study, the patients were divided into 2 groups upon AF recurrence after RFCA: Recurrent group, n = 67 patients with rapid trial arrhythmia that lasted for more than 30 seconds at 3 months after RFCA and the Nonrecurrent group, n = 221. The clinical conditions were compared between the 2 groups. During the second phase of this study, based on the results in the first phase, the patients were divided into another 2 groups according to whether the ratio of E/E' ≥13 .45: Higher ratio of E/E' group, n = 55 and Lower ratio of E/E' group n = 233. The late AF recurrent rates were also compared between the 2 groups. During the first phase, the univariate analysis indicated that the risk factors( P < .05)for PAF late recurrence included early recurrence, E', and the ratio E/E'. The Cox multivariate analysis showed that the ratio of E/E' and early recurrence were the independent predictors for late PAF recurrence. The ratio of E/E' that was cut off at 13.45 also predicted atrial tachyarrhythmia recurrence with 40.3% sensitivity and 87.3% specificity. In the second phase, after completing the 1:1 matching, the Kaplan–Meier analysis indicated that the ratio of E/E' ≥ 13.45 was associated with further recurrences after RFCA (log-rank P = .009), compared to the patients with a ratio of E/E' < 13.45. The univariate Cox analysis indicated that an elevated ratio of E/E'(≥13.45) was the independent predictor for late PAF recurrence (HR = 3.322, 95%CI: 1.560–7.075, P = .002). However, the ratio of E/E' cut off at 13.25 predicted atrial tachyarrhythmia recurrence with 75% sensitivity and 62.2% specificity. The ratio of E/E' ≥ 13.25 is an important predictor of the late recurrence of paroxysmal atrial fibrillation (PAF) after radiofrequency catheter ablation (RFCA). … (more)
- Is Part Of:
- Medicine. Volume 99:Issue 17(2020)
- Journal:
- Medicine
- Issue:
- Volume 99:Issue 17(2020)
- Issue Display:
- Volume 99, Issue 17 (2020)
- Year:
- 2020
- Volume:
- 99
- Issue:
- 17
- Issue Sort Value:
- 2020-0099-0017-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-04
- Subjects:
- catheter ablation -- E/E' ratio -- late recurrence -- paroxysmal atrial fibrillation
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000019897 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13739.xml