Peristaltic Contrast Media Injection Improved Image Quality and Decreased Radiation and Contrast Dose When Compared With Direct Drive Injection During Liver Computed Tomography. Issue 2 (March 2020)
- Record Type:
- Journal Article
- Title:
- Peristaltic Contrast Media Injection Improved Image Quality and Decreased Radiation and Contrast Dose When Compared With Direct Drive Injection During Liver Computed Tomography. Issue 2 (March 2020)
- Main Title:
- Peristaltic Contrast Media Injection Improved Image Quality and Decreased Radiation and Contrast Dose When Compared With Direct Drive Injection During Liver Computed Tomography
- Authors:
- Saade, Charbel
Karout, Lina
Khalife, Sarah
Mayat, Ahmad
Pillay, Sugendran
Chan, Edward
Maroun, Gilbert
Alam, Raquelle
Shattal, Mohammad Abu
Naffaa, Lena - Abstract:
- Abstract : Purpose: The aim of this study was to compare hepatic vascular and parenchymal image quality between direct and peristaltic contrast injectors during hepatic computed tomography (HCT). Methods: Patients (n = 171) who underwent enhanced HCT and had both contrast media protocols and injector systems were included; group A: direct-drive injector with fixed 100 mL contrast volume (CV), and group B: peristaltic injector with weight-based CV. Opacification, contrast-to-noise ratio, signal-to-noise ratio, radiation dose, and CV for liver parenchyma and vessels in both groups were compared by paired t test and Pearson correlation. Receiver operating characteristic curve, visual grading characteristics, and Cohen κ were used. Results: Contrast-to-noise ratio: compared with hepatic vein for functional liver, contrast-to-noise ratio was higher in group B (2.17 ± 0.83) than group A (1.82 ± 0.63); portal vein: higher in group B (2.281 ± 0.96) than group A (2.00 ± 0.66). Signal-to-noise ratio for functional liver was higher in group B (5.79 ± 1.58 Hounsfield units) than group A (4.81 ± 1.53 Hounsfield units). Radiation dose and contrast media were lower in group B (1.98 ± 0.92 mSv) (89.51 ± 15.49 mL) compared with group A (2.77 ± 1.03 mSv) (100 ± 1.00 mL). Receiver operating characteristic curve demonstrated increased reader in group B (95% confidence interval, 0.524–1.0) than group A (95% confidence interval, 0.545–1.0). Group B had increased revenue up to 58% compared withAbstract : Purpose: The aim of this study was to compare hepatic vascular and parenchymal image quality between direct and peristaltic contrast injectors during hepatic computed tomography (HCT). Methods: Patients (n = 171) who underwent enhanced HCT and had both contrast media protocols and injector systems were included; group A: direct-drive injector with fixed 100 mL contrast volume (CV), and group B: peristaltic injector with weight-based CV. Opacification, contrast-to-noise ratio, signal-to-noise ratio, radiation dose, and CV for liver parenchyma and vessels in both groups were compared by paired t test and Pearson correlation. Receiver operating characteristic curve, visual grading characteristics, and Cohen κ were used. Results: Contrast-to-noise ratio: compared with hepatic vein for functional liver, contrast-to-noise ratio was higher in group B (2.17 ± 0.83) than group A (1.82 ± 0.63); portal vein: higher in group B (2.281 ± 0.96) than group A (2.00 ± 0.66). Signal-to-noise ratio for functional liver was higher in group B (5.79 ± 1.58 Hounsfield units) than group A (4.81 ± 1.53 Hounsfield units). Radiation dose and contrast media were lower in group B (1.98 ± 0.92 mSv) (89.51 ± 15.49 mL) compared with group A (2.77 ± 1.03 mSv) (100 ± 1.00 mL). Receiver operating characteristic curve demonstrated increased reader in group B (95% confidence interval, 0.524–1.0) than group A (95% confidence interval, 0.545–1.0). Group B had increased revenue up to 58% compared with group A. Conclusions: Image quality improvement is achieved with lower CV and radiation dose when using peristaltic injector with weight-based CV in HCT. … (more)
- Is Part Of:
- Journal of computer assisted tomography. Volume 44:Issue 2(2020)
- Journal:
- Journal of computer assisted tomography
- Issue:
- Volume 44:Issue 2(2020)
- Issue Display:
- Volume 44, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 44
- Issue:
- 2
- Issue Sort Value:
- 2020-0044-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-03
- Subjects:
- computed tomography -- contrast media -- injector -- liver
Tomography -- Periodicals
Tomography -- Periodicals
Tomography
Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/jcat/pages/default.aspx ↗
http://ovidsp.tx.ovid.com ↗
http://www.jcat.org ↗
http://www.rad.bqsm.edu/jcat ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0363-8715 ↗ - DOI:
- 10.1097/RCT.0000000000000994 ↗
- Languages:
- English
- ISSNs:
- 0363-8715
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4963.650000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13743.xml