Stability of 21 Antihypertensive Drugs in Serum Collected in Standard (Nongel) Serum Tubes Versus Tubes Containing a Gel Separator. Issue 2 (April 2020)
- Record Type:
- Journal Article
- Title:
- Stability of 21 Antihypertensive Drugs in Serum Collected in Standard (Nongel) Serum Tubes Versus Tubes Containing a Gel Separator. Issue 2 (April 2020)
- Main Title:
- Stability of 21 Antihypertensive Drugs in Serum Collected in Standard (Nongel) Serum Tubes Versus Tubes Containing a Gel Separator
- Authors:
- Hegstad, Solfrid
Spigset, Olav
Helland, Arne - Abstract:
- Abstract : Background: Therapeutic drug monitoring of antihypertensive drugs is being increasingly used to optimize treatment and to assess nonadherence. Separator gels are often used in blood collection tubes to facilitate serum or plasma separation from other blood constituents before analyses. Drug adsorption into the separator gel presents a possible pre-analytical cause of falsely low concentrations or false negative results. Methods: Drug-free blood from blood donors was spiked with therapeutic concentrations of 21 antihypertensive drugs, transferred to serum tubes with and without separator gel (Vacuette gel plastic tubes and plain serum plastic tubes, respectively), and centrifuged. Serum was collected immediately after centrifugation and after 24 and 72 hours of room temperature storage, samples were analyzed in triplicates using liquid chromatography–mass spectrometry. Results: Serum samples collected immediately after centrifugation or 24 hours later, had the same drug concentrations in the gel and nongel tubes. After 72 hours of room temperature storage, verapamil and lercanidipine serum concentrations were 43% and 29%, respectively, lower in gel tubes than nongel tubes. Canrenone, diltiazem, and bendroflumethiazide showed between 10% and 20% concentration loss in gel tubes, compared with nongel tubes, with the 2 latter observed as unstable also in nongel tubes. Conclusions: Except for verapamil, lercanidipine, and canrenone, which showed substantialAbstract : Background: Therapeutic drug monitoring of antihypertensive drugs is being increasingly used to optimize treatment and to assess nonadherence. Separator gels are often used in blood collection tubes to facilitate serum or plasma separation from other blood constituents before analyses. Drug adsorption into the separator gel presents a possible pre-analytical cause of falsely low concentrations or false negative results. Methods: Drug-free blood from blood donors was spiked with therapeutic concentrations of 21 antihypertensive drugs, transferred to serum tubes with and without separator gel (Vacuette gel plastic tubes and plain serum plastic tubes, respectively), and centrifuged. Serum was collected immediately after centrifugation and after 24 and 72 hours of room temperature storage, samples were analyzed in triplicates using liquid chromatography–mass spectrometry. Results: Serum samples collected immediately after centrifugation or 24 hours later, had the same drug concentrations in the gel and nongel tubes. After 72 hours of room temperature storage, verapamil and lercanidipine serum concentrations were 43% and 29%, respectively, lower in gel tubes than nongel tubes. Canrenone, diltiazem, and bendroflumethiazide showed between 10% and 20% concentration loss in gel tubes, compared with nongel tubes, with the 2 latter observed as unstable also in nongel tubes. Conclusions: Except for verapamil, lercanidipine, and canrenone, which showed substantial concentration loss in gel tubes, gel tubes may be used for therapeutic drug monitoring purposes for the most commonly used antihypertensive drugs. Transferring serum to gel-free containers immediately after centrifugation minimizes concentration loss; however, bendroflumethiazide and diltiazem are generally unstable at room temperature. … (more)
- Is Part Of:
- Therapeutic drug monitoring. Volume 42:Issue 2(2020:Apr.)
- Journal:
- Therapeutic drug monitoring
- Issue:
- Volume 42:Issue 2(2020:Apr.)
- Issue Display:
- Volume 42, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 42
- Issue:
- 2
- Issue Sort Value:
- 2020-0042-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-04
- Subjects:
- therapeutic drug monitoring -- antihypertensive drug -- pre-analytical storage -- serum tube -- gel separator
Pharmacokinetics -- Periodicals
Patient monitoring -- Periodicals
Drugs -- Analysis -- Periodicals
Body fluids -- Analysis -- Periodicals
Drug Therapy -- Periodicals
Monitoring, Physiologic -- Periodicals
Pharmacology -- Periodicals
615.7 - Journal URLs:
- http://journals.lww.com/drug-monitoring/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00007691-000000000-00000 ↗
http://www.drug-monitoring.com/ ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0163-4356 ↗ - DOI:
- 10.1097/FTD.0000000000000708 ↗
- Languages:
- English
- ISSNs:
- 0163-4356
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8814.643000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13740.xml