Use of CAD-based pre-bent implants reduces theatre time in orbital floor reconstruction: results of a prospective study. Issue 7 (September 2020)
- Record Type:
- Journal Article
- Title:
- Use of CAD-based pre-bent implants reduces theatre time in orbital floor reconstruction: results of a prospective study. Issue 7 (September 2020)
- Main Title:
- Use of CAD-based pre-bent implants reduces theatre time in orbital floor reconstruction: results of a prospective study
- Authors:
- von Wilmowsky, C.
Schwertner, M.G.
Nkenke, E.
Moest, T.
Adler, W.
Ebker, T. - Abstract:
- Abstract: In this prospective study we evaluated the duration of insertion and the accuracy of fitting of computer-aided design (CAD)-based pre-bent orbital floor plates compared with non-preformed orbital plates in reconstruction of the orbital floor. Thirty-six patients with unilateral fractures of the orbital floor were included; pre-bent plates were used in 25 and non-preformed plates in 11. Preoperative computed tomography (CT) scans were used for CAD of individualised implants. The anatomy of the affected orbit was virtually reconstructed "slice by slice". Individually pre-bent plates were generated using a stereolithographic model of the reconstructed orbit. The mean (SD) duration of insertion was significantly reduced when pre-bent orbital plates were used (5.5 (5.4) min) compared with non-preformed meshes (11.1 (7.7) min). The congruence of pre-bent plates to the infraorbital rim did not differ from that of non-preformed plates. The accuracy of fit was rated as "accurate" in 24 cases. CAD-based individualised titanium meshes reduce theatre time compared with non-preformed orbital plates. Our results confirm the efficacy of CAD-based pre-bent plates in reconstruction of the orbital floor.
- Is Part Of:
- British journal of oral and maxillofacial surgery. Volume 58:Issue 7(2020)
- Journal:
- British journal of oral and maxillofacial surgery
- Issue:
- Volume 58:Issue 7(2020)
- Issue Display:
- Volume 58, Issue 7 (2020)
- Year:
- 2020
- Volume:
- 58
- Issue:
- 7
- Issue Sort Value:
- 2020-0058-0007-0000
- Page Start:
- 753
- Page End:
- 758
- Publication Date:
- 2020-09
- Subjects:
- intraoperative time comparison -- individually pre-bent titanium mesh -- computer-aided design -- orbital floor fracture -- orbital floor reconstruction
Mouth -- Surgery -- Periodicals
Maxilla -- Surgery -- Periodicals
Face -- Surgery -- Periodicals
Surgery, Plastic -- Periodicals
Dentistry, Operative -- Periodicals
Face -- surgery -- Periodicals
Mouth -- surgery -- Periodicals
Maxilla -- surgery -- Periodicals
Surgery, Oral -- Periodicals
Oral Surgical Procedures -- Periodicals
Dentistry, Operative -- Periodicals
Bouche -- Chirurgie -- Périodiques
Maxillaire supérieur -- Chirurgie -- Périodiques
Face -- Chirurgie -- Périodiques
Chirurgie dentaire -- Périodiques
Dentistry, Operative
Face -- Surgery
Maxilla -- Surgery
Mouth -- Surgery
Surgery, Plastic
Electronic journals
Periodicals
617.52059 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02664356 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.bjoms.2019.11.020 ↗
- Languages:
- English
- ISSNs:
- 0266-4356
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2314.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13720.xml