Comparison of the Accuracy of Implant Position Using Surgical Guides Fabricated by Additive and Subtractive Techniques. Issue 6 (6th May 2020)
- Record Type:
- Journal Article
- Title:
- Comparison of the Accuracy of Implant Position Using Surgical Guides Fabricated by Additive and Subtractive Techniques. Issue 6 (6th May 2020)
- Main Title:
- Comparison of the Accuracy of Implant Position Using Surgical Guides Fabricated by Additive and Subtractive Techniques
- Authors:
- Henprasert, Pantip
Dawson, Deborah V.
El‐Kerdani, Tarek
Song, Xuan
Couso‐Queiruga, Emilio
Holloway, Julie A. - Abstract:
- Abstract: Purpose: To evaluate the accuracy of implant position using surgical guides fabricated by additive and subtractive techniques. Materials and Methods: A partially edentulous standardized mandibular implant model with different bone densities and soft tissue was duplicated and a diagnostic wax‐up was performed for the #30 area. A reference radiographic guide was fabricated and cone beam computed tomography (CBCT) was made with the reference radiographic guide in place. A surgical guide was designed using BlueSky Plan 4 software and a reference implant was placed in the #30 region. The STL file of the surgical guide was exported and specimens (n = 15) were fabricated by two different techniques: additive (3D printing) and subtractive (milling). The standardized mandibular model was surface‐scanned and duplicated with printed dental model resin (n = 30). Each surgical guide was used to place an implant in thirty duplicate printed models. Differences in implant position as compared to the reference were measured from digital scans with scan bodies in place. The angular deviations, differences in depth, coronal and apical deviations were measured using GeoMagic Control X software. Results were analyzed by Wilcoxon‐Mann‐Whitney test and PERMANOVA (Permutational Multivariate Analysis of Variance). Intraclass correlation was used to assess measurement reproducibility with Bonferroni adjustment for multiple testing as needed (α = 0.05). Results: There were no significantAbstract: Purpose: To evaluate the accuracy of implant position using surgical guides fabricated by additive and subtractive techniques. Materials and Methods: A partially edentulous standardized mandibular implant model with different bone densities and soft tissue was duplicated and a diagnostic wax‐up was performed for the #30 area. A reference radiographic guide was fabricated and cone beam computed tomography (CBCT) was made with the reference radiographic guide in place. A surgical guide was designed using BlueSky Plan 4 software and a reference implant was placed in the #30 region. The STL file of the surgical guide was exported and specimens (n = 15) were fabricated by two different techniques: additive (3D printing) and subtractive (milling). The standardized mandibular model was surface‐scanned and duplicated with printed dental model resin (n = 30). Each surgical guide was used to place an implant in thirty duplicate printed models. Differences in implant position as compared to the reference were measured from digital scans with scan bodies in place. The angular deviations, differences in depth, coronal and apical deviations were measured using GeoMagic Control X software. Results were analyzed by Wilcoxon‐Mann‐Whitney test and PERMANOVA (Permutational Multivariate Analysis of Variance). Intraclass correlation was used to assess measurement reproducibility with Bonferroni adjustment for multiple testing as needed (α = 0.05). Results: There were no significant differences in accuracy of implant placement using guides fabricated using additive vs subtractive techniques. The mean angular deviations between the reference and actual position of implant in mesio‐distal cross‐section were 0.780 ± 0.80° for printed group and 0.77 ± 0.72° for the milled group. The differences in bucco‐lingual cross‐section were 1.60 ± 1.22° in in printed group and 1.77 ± 0.76° in the milled group. The differences in depth (mm) were measured at the top of the scan body at four locations: mesial, distal, buccal and lingual. The mean differences in depth for the group that used printed surgical guides were (mesial) 0.37 ± 0.29 mm, (distal) 0.32 ± 0.23 mm, (buccal) 0.24 ± 0.23 mm, and (lingual) 0.25 ± 0.17 mm. The mean differences in depth for the group that used milled surgical guides were (mesial) 0.51 ± 0.33 mm, (distal) 0.40 ± 0.32 mm, (buccal) 0.22 ± 0.23 mm, and (lingual) 0.23 ± 0.12 mm in those four aspects, respectively. The mean coronal deviation showed 0.32 mm in the printed group and 0.27 mm in the milled group. For the apical deviation, the results of this study showed mean apical deviation 0.84 mm in the printed group and 0.80 mm in the milled group. Conclusions: Results indicate that 3D‐printed surgical guides are statistically as accurate as milled guides for guided‐implant surgery with the benefits of high accuracy, ease of fabrication, less waste compared to subtractive techniques, and reduction of laboratory time thereby increasing cost‐effectiveness. … (more)
- Is Part Of:
- Journal of prosthodontics. Volume 29:Issue 6(2020)
- Journal:
- Journal of prosthodontics
- Issue:
- Volume 29:Issue 6(2020)
- Issue Display:
- Volume 29, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 29
- Issue:
- 6
- Issue Sort Value:
- 2020-0029-0006-0000
- Page Start:
- 534
- Page End:
- 541
- Publication Date:
- 2020-05-06
- Subjects:
- 3D printing -- 3D milling -- accuracy of implant position -- surgical guide -- dental implant -- guided surgery
Prosthodontics -- Periodicals
Dental implants -- Periodicals
Dentistry -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1532-849X ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=jopr ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jopr.13161 ↗
- Languages:
- English
- ISSNs:
- 1059-941X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5042.920000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13714.xml