Fully Integrated, Stretchable, Wireless Skin‐Conformal Bioelectronics for Continuous Stress Monitoring in Daily Life. Issue 15 (15th June 2020)
- Record Type:
- Journal Article
- Title:
- Fully Integrated, Stretchable, Wireless Skin‐Conformal Bioelectronics for Continuous Stress Monitoring in Daily Life. Issue 15 (15th June 2020)
- Main Title:
- Fully Integrated, Stretchable, Wireless Skin‐Conformal Bioelectronics for Continuous Stress Monitoring in Daily Life
- Authors:
- Kim, Hojoong
Kim, Yun‐Soung
Mahmood, Musa
Kwon, Shinjae
Zavanelli, Nathan
Kim, Hee Seok
Rim, You Seung
Epps, Fayron
Yeo, Woon‐Hong - Abstract:
- Abstract: Stress is one of the main causes that increase the risk of serious health problems. Recent wearable devices have been used to monitor stress levels via electrodermal activities on the skin. Although many biosensors provide adequate sensing performance, they still rely on uncomfortable, partially flexible systems with rigid electronics. These devices are mounted on either fingers or palms, which hinders a continuous signal monitoring. A fully‐integrated, stretchable, wireless skin‐conformal bioelectronic (referred to as "SKINTRONICS") is introduced here that integrates soft, multi‐layered, nanomembrane sensors and electronics for continuous and portable stress monitoring in daily life. The all‐in‐one SKINTRONICS is ultrathin, highly soft, and lightweight, which overall offers an ergonomic and conformal lamination on the skin. Stretchable nanomembrane electrodes and a digital temperature sensor enable highly sensitive monitoring of galvanic skin response (GSR) and temperature. A set of comprehensive signal processing, computational modeling, and experimental study provides key aspects of device design, fabrication, and optimal placing location. Simultaneous comparison with two commercial stress monitors captures the enhanced performance of SKINTRONICS in long‐term wearability, minimal noise, and skin compatibility. In vivo demonstration of continuous stress monitoring in daily life reveals the unique capability of the soft device as a real‐world applicable stressAbstract: Stress is one of the main causes that increase the risk of serious health problems. Recent wearable devices have been used to monitor stress levels via electrodermal activities on the skin. Although many biosensors provide adequate sensing performance, they still rely on uncomfortable, partially flexible systems with rigid electronics. These devices are mounted on either fingers or palms, which hinders a continuous signal monitoring. A fully‐integrated, stretchable, wireless skin‐conformal bioelectronic (referred to as "SKINTRONICS") is introduced here that integrates soft, multi‐layered, nanomembrane sensors and electronics for continuous and portable stress monitoring in daily life. The all‐in‐one SKINTRONICS is ultrathin, highly soft, and lightweight, which overall offers an ergonomic and conformal lamination on the skin. Stretchable nanomembrane electrodes and a digital temperature sensor enable highly sensitive monitoring of galvanic skin response (GSR) and temperature. A set of comprehensive signal processing, computational modeling, and experimental study provides key aspects of device design, fabrication, and optimal placing location. Simultaneous comparison with two commercial stress monitors captures the enhanced performance of SKINTRONICS in long‐term wearability, minimal noise, and skin compatibility. In vivo demonstration of continuous stress monitoring in daily life reveals the unique capability of the soft device as a real‐world applicable stress monitor. Abstract : Continuous, wireless monitoring of stress in daily life is enabled by the development of a fully integrated, stretchable, skin‐conformal bioelectronic that includes nanomembrane sensors and stretchable circuits for a highly sensitive galvanic skin response and temperature monitoring with negligible motion artifacts. … (more)
- Is Part Of:
- Advanced science. Volume 7:Issue 15(2020)
- Journal:
- Advanced science
- Issue:
- Volume 7:Issue 15(2020)
- Issue Display:
- Volume 7, Issue 15 (2020)
- Year:
- 2020
- Volume:
- 7
- Issue:
- 15
- Issue Sort Value:
- 2020-0007-0015-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2020-06-15
- Subjects:
- continuous stress monitors -- galvanic skin response (GSR) -- stretchable bioelectronics -- temperature monitoring -- wireless soft electronics
Science -- Periodicals
505 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2198-3844 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/advs.202000810 ↗
- Languages:
- English
- ISSNs:
- 2198-3844
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13717.xml