Efficient Adsorptive Separation and Determination of Phenolic Acids from Orange Peels Using Hyper-Crosslinked Polymer Based Zeolitic Imidazolate Framework-8 (ZIF-8) Composites. (1st November 2020)
- Record Type:
- Journal Article
- Title:
- Efficient Adsorptive Separation and Determination of Phenolic Acids from Orange Peels Using Hyper-Crosslinked Polymer Based Zeolitic Imidazolate Framework-8 (ZIF-8) Composites. (1st November 2020)
- Main Title:
- Efficient Adsorptive Separation and Determination of Phenolic Acids from Orange Peels Using Hyper-Crosslinked Polymer Based Zeolitic Imidazolate Framework-8 (ZIF-8) Composites
- Authors:
- Sun, Liping
Tang, Weiyang
Zhu, Tao
Row, Kyung Ho - Abstract:
- Abstract: A new and efficient hypercrosslinked polymer-based zeolitic imidazolate framework-8 composite called ZIF-8-HCP was synthesized. The properties of the material including zeolitic imidazolate framework-8 and hypercrosslinked polymer were analyzed using seven characterization methods. In addition, the materials were used as adsorbents for the dispersion solid-phase extraction for the separation and determination of phenolic acids in orange peel samples. The adsorption capacities of the resulting materials were characterized. The selectivity of zeolitic imidazolate framework-8 was greatly enhanced after the introduction of a hyper-crosslinked polymer as the skeleton. The microstructure modification introduced a large number of mesoporous sites that allowed better adsorption of the caffeic acid and ferulic acid targets. The adsorption capacities of the composite ZIF-8-HCP were 31.72 mg/g for the former and 15.58 mg/g for the latter. In addition, the limits of detection and quantification were 0.0188 and 0.0627 μg/mL and 0.0177 and 0.0592 μg/mL, respectively. A feasible analytical method was established for the targets in orange peel samples using the ZIF-8-HCP with satisfactory extraction recoveries of 92.90% and 98.87%. The proposed method using the synthesized material was employed to the trace determination of the phenolic acids by high-performance liquid chromatography (HPLC).
- Is Part Of:
- Analytical letters. Volume 53:Number 16(2020)
- Journal:
- Analytical letters
- Issue:
- Volume 53:Number 16(2020)
- Issue Display:
- Volume 53, Issue 16 (2020)
- Year:
- 2020
- Volume:
- 53
- Issue:
- 16
- Issue Sort Value:
- 2020-0053-0016-0000
- Page Start:
- 2636
- Page End:
- 2655
- Publication Date:
- 2020-11-01
- Subjects:
- dispersion solid-phase extraction (DSPE) -- high-performance liquid chromatography (HPLC) -- hyper-crosslinked polymer -- phenolic acids -- zeolitic imidazolate framework-8 (ZIF-8)
Chemistry, Analytic -- Periodicals
Chemistry, Analytic -- Abstracts
543 - Journal URLs:
- http://www.tandfonline.com/toc/lanl20/current ↗
http://taylorandfrancis.metapress.com/link.asp?id=107818, ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/00032719.2020.1751180 ↗
- Languages:
- English
- ISSNs:
- 0003-2719
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.100000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13701.xml