A dual-intake-port technology as a design option for a Sliding Vane Rotary Expander of small-scale ORC-based power units. (1st April 2020)
- Record Type:
- Journal Article
- Title:
- A dual-intake-port technology as a design option for a Sliding Vane Rotary Expander of small-scale ORC-based power units. (1st April 2020)
- Main Title:
- A dual-intake-port technology as a design option for a Sliding Vane Rotary Expander of small-scale ORC-based power units
- Authors:
- Fatigati, Fabio
Di Bartolomeo, Marco
Di Battista, Davide
Cipollone, Roberto - Abstract:
- Graphical abstract: Highlights: Experimental comparison between single (SIP) and dual intake port (DIP) expander. Development of theoretical model for DIP SVRE design; The DIP allows the SVRE downsizing producing a comparable power than SIP expander. DIP introduction on SVRE allows to elaborate the same flow rate reducing pressure. DIP introduction increases mass flow rate aspirated with constant inlet pressure. Abstract: Volumetric machines are the most suitable candidates to be used as expander in power units based on the Organic Rankine Cycle (ORC) thermodynamic concept, for waste heat recovery of Internal Combustion Engine in the on-the-road transportation sector. In particular, the technology of the Sliding Rotary Vane Expander (SRVE) shows intrinsic advantages thanks to their lower cost, shaping features, easier manufacturing and reliability and, generally speaking, very suitable operative conditions. Nevertheless, they show some disadvantages which are typical of volumetric machines, such as low capacity, limited expansion ratio and power lost by friction. Among the different technologies available to reduce the effects of these aspects (revolution speed increase, elliptical stators or with more complex geometries, tip blade optimization, rolling stators, etc.), the Dual-Intake Port (DIP) was assessed as a promising solution to enhance SVREs performance and operability. However, dual-intake port was still not conceived as design option. In this paper, a novel SlidingGraphical abstract: Highlights: Experimental comparison between single (SIP) and dual intake port (DIP) expander. Development of theoretical model for DIP SVRE design; The DIP allows the SVRE downsizing producing a comparable power than SIP expander. DIP introduction on SVRE allows to elaborate the same flow rate reducing pressure. DIP introduction increases mass flow rate aspirated with constant inlet pressure. Abstract: Volumetric machines are the most suitable candidates to be used as expander in power units based on the Organic Rankine Cycle (ORC) thermodynamic concept, for waste heat recovery of Internal Combustion Engine in the on-the-road transportation sector. In particular, the technology of the Sliding Rotary Vane Expander (SRVE) shows intrinsic advantages thanks to their lower cost, shaping features, easier manufacturing and reliability and, generally speaking, very suitable operative conditions. Nevertheless, they show some disadvantages which are typical of volumetric machines, such as low capacity, limited expansion ratio and power lost by friction. Among the different technologies available to reduce the effects of these aspects (revolution speed increase, elliptical stators or with more complex geometries, tip blade optimization, rolling stators, etc.), the Dual-Intake Port (DIP) was assessed as a promising solution to enhance SVREs performance and operability. However, dual-intake port was still not conceived as design option. In this paper, a novel Sliding Vane Rotary Expander design concept involving a Dual Intake Port expander (DIP) option was developed and compared to the conventional Single Intake Port (SIP) one, under the same operating conditions. Thus, after an experimental comparison between SIP and DIP expanders, under the same conditions of mass flowrate, a theoretical expander model of the latter was validated on a set of experimental results. The model allows to outline the advantages of considering the dual port as a design option: for a specific flow rate and revolution speed, this option allows to reduce the friction losses, which represent a weak point of this volumetric machine. For a given mass flow rate of the working fluid, an additional feature is that it allows a sensible downsizing with respect to the SIP, with an axial dimension reduction up to 50%, ensuring additional weight and space saving. Despite the reduction of the dimensions, DIP produces a comparable mechanical power with respect to SIP, limiting the reduction to 8–10% of the SIP one with a 50% lower mechanical power loss due to friction. For the same flow rate, the added intake port determines a decrease of the intake pressure which is completely beneficial in terms of operating conditions of the overall recovery unit. … (more)
- Is Part Of:
- Energy conversion and management. Volume 209(2020)
- Journal:
- Energy conversion and management
- Issue:
- Volume 209(2020)
- Issue Display:
- Volume 209, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 209
- Issue:
- 2020
- Issue Sort Value:
- 2020-0209-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-04-01
- Subjects:
- Sliding Vane Rotary Expander Design -- Downsizing -- Dual Intake Port -- Organic Rankine Cycle -- Exhaust Gases Waste Heat Recovery -- Friction Power Loss Reduction
Direct energy conversion -- Periodicals
Energy storage -- Periodicals
Energy transfer -- Periodicals
Énergie -- Conversion directe -- Périodiques
Direct energy conversion
Periodicals
621.3105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01968904 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.enconman.2020.112646 ↗
- Languages:
- English
- ISSNs:
- 0196-8904
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3747.547000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13697.xml