Survey results of 3D‐CRT and IMRT quality assurance practice. Issue 7 (30th April 2020)
- Record Type:
- Journal Article
- Title:
- Survey results of 3D‐CRT and IMRT quality assurance practice. Issue 7 (30th April 2020)
- Main Title:
- Survey results of 3D‐CRT and IMRT quality assurance practice
- Authors:
- Mehrens, Hunter
Taylor, Paige
Followill, David S.
Kry, Stephen F. - Abstract:
- Abstract: Purpose: To create a snapshot of common practices for 3D‐CRT and intensity‐modulated radiation therapy (IMRT) QA through a large‐scale survey and compare to TG‐218 recommendations. Methods: A survey of 3D‐CRT and IMRT QA was constructed at and distributed by the IROC‐Houston QA center to all institutions monitored by IROC (n = 2, 861). The first part of the survey asked about methods to check dose delivery for 3D‐CRT. The bulk of the survey focused on IMRT QA, inquiring about treatment modalities, standard tools used to verify planned dose, how assessment of agreement is calculated and the comparison criteria used, and the strategies taken if QA fails. Results: The most common tools for dose verification were a 2D diode array (52.8%), point(s) measurement (39.0%), EPID (27.4%), and 2D ion chamber array (23.9%). When IMRT QA failed, the highest average rank strategy utilized was to remeasure with the same setup, which had an average position ranking of 1.1 with 90.4% of facilities employing this strategy. The second highest average ranked strategy was to move to a new calculation point and remeasure (54.9%); this had an average ranking of 2.1. Conclusion: The survey provided a snapshot of the current state of dose verification for IMRT radiotherapy. The results showed variability in approaches and that work is still needed to unify and tighten criteria in the medical physics community, especially in reference to TG‐218's recommendations.
- Is Part Of:
- Journal of applied clinical medical physics. Volume 21:Issue 7(2020)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 21:Issue 7(2020)
- Issue Display:
- Volume 21, Issue 7 (2020)
- Year:
- 2020
- Volume:
- 21
- Issue:
- 7
- Issue Sort Value:
- 2020-0021-0007-0000
- Page Start:
- 70
- Page End:
- 76
- Publication Date:
- 2020-04-30
- Subjects:
- dose verification -- IMRT QA -- patient specific QA -- survey -- TG‐218
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12885 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13665.xml